Compare commits

..
1 Commits
Author SHA1 Message Date
Nigel 922e1fc2ae Preparing release 0.29 2021-04-18 12:48:25 +02:00
14 changed files with 31 additions and 167 deletions
-45
View File
@@ -1,45 +0,0 @@
name: Tests
on:
push: ~
pull_request: ~
jobs:
build:
runs-on: ubuntu-latest
timeout-minutes: 10 # Don't run forever when stale
strategy:
matrix:
python-version:
- 3.6
- 3.7
- 3.8
- 3.9
name: Python ${{ matrix.python-version }}
steps:
- uses: actions/checkout@v2
- name: Setup Python ${{ matrix.python-version }}
uses: actions/setup-python@v2
with:
python-version: ${{ matrix.python-version }}
- name: Cached PIP dependencies
uses: actions/cache@v2
with:
path: |
~/.cache/pip
~/.tox/python/.pytest_cache
key: pip-${{ matrix.python-version }}-${{ hashFiles('setup.py', 'tox.ini') }}
restore-keys: pip-${{ matrix.python-version }}-
- name: Install dependencies
run: pip install tox
- name: Run tests
run: tox
- name: Code coverage upload
uses: codecov/codecov-action@v1
+18
View File
@@ -0,0 +1,18 @@
language: python
python:
- 2.7
- 3.5
- 3.6
- 3.8
install: pip install tox-travis codecov
script: tox
after_success:
- codecov
matrix:
allow_failures:
- python: 2.7
+1 -7
View File
@@ -1,15 +1,9 @@
Change Log
----------
**0.31** (2021-11-21)
- Support for (German) EasyMeter Q3D using COM-1 Ethernet Gateway (`pull request #92 <https://github.com/ndokter/dsmr_parser/pull/92>`_).
**0.30** (2021-08-18)
- Add support for Swedish smart meters (`pull request #86 <https://github.com/ndokter/dsmr_parser/pull/86>`_).
**0.29** (2021-04-18)
- Add value and unit properties to ProfileGenericObject to make sure that code like iterators that rely on that do not break (`pull request #71 <https://github.com/ndokter/dsmr_parser/pull/71>`_).
Remove deprecated asyncio coroutine decorator (`pull request #76 <https://github.com/ndokter/dsmr_parser/pull/76>`_).
- Remove deprecated asyncio coroutine decorator (`pull request #76 <https://github.com/ndokter/dsmr_parser/pull/76>`_).
**0.28** (2021-02-21)
- Optional keep alive monitoring for TCP/IP connections (`pull request #73 <https://github.com/ndokter/dsmr_parser/pull/73>`_).
-3
View File
@@ -1,6 +1,3 @@
**Notice:** this repository is in need of a new maintainer. If you are interested or have ideas about this, please let me know.
DSMR Parser
===========
+2 -2
View File
@@ -16,8 +16,8 @@ def console():
help='alternatively connect using TCP host.')
parser.add_argument('--port', default=None,
help='TCP port to use for connection')
parser.add_argument('--version', default='2.2', choices=['2.2', '4', '5', '5B', '5L', '5S', 'Q3D'],
help='DSMR version (2.2, 4, 5, 5B, 5L, 5S, Q3D)')
parser.add_argument('--version', default='2.2', choices=['2.2', '4', '5', '5B', '5L'],
help='DSMR version (2.2, 4, 5, 5B, 5L)')
parser.add_argument('--verbose', '-v', action='count')
args = parser.parse_args()
+1 -14
View File
@@ -23,9 +23,6 @@ def create_dsmr_protocol(dsmr_version, telegram_callback, loop=None, **kwargs):
elif dsmr_version == '4':
specification = telegram_specifications.V4
serial_settings = SERIAL_SETTINGS_V4
elif dsmr_version == '4+':
specification = telegram_specifications.V5
serial_settings = SERIAL_SETTINGS_V4
elif dsmr_version == '5':
specification = telegram_specifications.V5
serial_settings = SERIAL_SETTINGS_V5
@@ -35,12 +32,6 @@ def create_dsmr_protocol(dsmr_version, telegram_callback, loop=None, **kwargs):
elif dsmr_version == "5L":
specification = telegram_specifications.LUXEMBOURG_SMARTY
serial_settings = SERIAL_SETTINGS_V5
elif dsmr_version == "5S":
specification = telegram_specifications.SWEDEN
serial_settings = SERIAL_SETTINGS_V5
elif dsmr_version == "Q3D":
specification = telegram_specifications.Q3D
serial_settings = SERIAL_SETTINGS_V5
else:
raise NotImplementedError("No telegram parser found for version: %s",
dsmr_version)
@@ -105,16 +96,12 @@ class DSMRProtocol(asyncio.Protocol):
def data_received(self, data):
"""Add incoming data to buffer."""
# accept latin-1 (8-bit) on the line, to allow for non-ascii transport or padding
data = data.decode("latin1")
data = data.decode('ascii')
self._active = True
self.log.debug('received data: %s', data)
self.telegram_buffer.append(data)
for telegram in self.telegram_buffer.get_all():
# ensure actual telegram is ascii (7-bit) only (IEC 646 required in section 5.4 of IEC 62056-21)
telegram = telegram.encode("latin1").decode("ascii")
self.handle_telegram(telegram)
def keep_alive(self):
+1
View File
@@ -1,3 +1,4 @@
import asyncio
import logging
import serial
import serial_asyncio
+1 -7
View File
@@ -13,7 +13,6 @@ EN = {
obis.ELECTRICITY_IMPORTED_TOTAL: 'ELECTRICITY_IMPORTED_TOTAL',
obis.ELECTRICITY_USED_TARIFF_1: 'ELECTRICITY_USED_TARIFF_1',
obis.ELECTRICITY_USED_TARIFF_2: 'ELECTRICITY_USED_TARIFF_2',
obis.ELECTRICITY_EXPORTED_TOTAL: 'ELECTRICITY_EXPORTED_TOTAL',
obis.ELECTRICITY_DELIVERED_TARIFF_1: 'ELECTRICITY_DELIVERED_TARIFF_1',
obis.ELECTRICITY_DELIVERED_TARIFF_2: 'ELECTRICITY_DELIVERED_TARIFF_2',
obis.ELECTRICITY_ACTIVE_TARIFF: 'ELECTRICITY_ACTIVE_TARIFF',
@@ -53,12 +52,7 @@ EN = {
obis.BELGIUM_HOURLY_GAS_METER_READING: 'BELGIUM_HOURLY_GAS_METER_READING',
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: 'LUXEMBOURG_EQUIPMENT_IDENTIFIER',
obis.LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL: 'LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL',
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL',
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
obis.Q3D_EQUIPMENT_IDENTIFIER: 'Q3D_EQUIPMENT_IDENTIFIER',
obis.Q3D_EQUIPMENT_STATE: 'Q3D_EQUIPMENT_STATE',
obis.Q3D_EQUIPMENT_SERIALNUMBER: 'Q3D_EQUIPMENT_SERIALNUMBER',
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL'
}
REVERSE_EN = dict([(v, k) for k, v in EN.items()])
-6
View File
@@ -11,7 +11,6 @@ P1_MESSAGE_TIMESTAMP = r'\d-\d:1\.0\.0.+?\r\n'
ELECTRICITY_IMPORTED_TOTAL = r'\d-\d:1\.8\.0.+?\r\n'
ELECTRICITY_USED_TARIFF_1 = r'\d-\d:1\.8\.1.+?\r\n'
ELECTRICITY_USED_TARIFF_2 = r'\d-\d:1\.8\.2.+?\r\n'
ELECTRICITY_EXPORTED_TOTAL = r'\d-\d:2\.8\.0.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_1 = r'\d-\d:2\.8\.1.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_2 = r'\d-\d:2\.8\.2.+?\r\n'
ELECTRICITY_ACTIVE_TARIFF = r'\d-\d:96\.14\.0.+?\r\n'
@@ -67,8 +66,3 @@ BELGIUM_HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.3.+?\r\n' # Different code, s
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'\d-\d:42\.0\.0.+?\r\n' # Logical device name
LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
Q3D_EQUIPMENT_IDENTIFIER = r'\d-\d:0\.0\.0.+?\r\n' # Logical device name
Q3D_EQUIPMENT_STATE = r'\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal)
Q3D_EQUIPMENT_SERIALNUMBER = r'\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber
-41
View File
@@ -156,44 +156,3 @@ LUXEMBOURG_SMARTY['objects'].update({
obis.LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
})
# Source: https://www.energiforetagen.se/globalassets/energiforetagen/det-erbjuder-vi/kurser-och-konferenser/elnat/
# branschrekommendation-lokalt-granssnitt-v2_0-201912.pdf
SWEDEN = {
'checksum_support': True,
'objects': {
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
}
}
Q3D = {
"checksum_support": False,
"objects": {
obis.Q3D_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.Q3D_EQUIPMENT_STATE: CosemParser(ValueParser(str)),
obis.Q3D_EQUIPMENT_SERIALNUMBER: CosemParser(ValueParser(str)),
},
}
+1 -2
View File
@@ -5,9 +5,8 @@ setup(
description='Library to parse Dutch Smart Meter Requirements (DSMR)',
author='Nigel Dokter and many others',
author_email='nigel@nldr.net',
license='MIT',
url='https://github.com/ndokter/dsmr_parser',
version='0.31',
version='0.29',
packages=find_packages(exclude=('test', 'test.*')),
install_requires=[
'pyserial>=3,<4',
-40
View File
@@ -128,43 +128,3 @@ TELEGRAM_V5 = (
'0-2:96.1.0()\r\n'
'!6EEE\r\n'
)
# EasyMeter via COM-1 Ethernet Gateway
# Q3D Manual (german) https://www.easymeter.com/downloads/products/zaehler/Q3D/Easymeter_Q3D_DE_2016-06-15.pdf
# - type code on page 8
# - D0-Specs on page 20
#
# last two lines are added by the COM-1 Ethernet Gateway
TELEGRAM_ESY5Q3DB1024_V304 = ( # Easymeter an Hauptstromzähler
'/ESY5Q3DB1024 V3.04\r\n'
'\r\n'
'1-0:0.0.0*255(0272031312565)\r\n'
'1-0:1.8.0*255(00052185.7825309*kWh)\r\n'
'1-0:2.8.0*255(00019949.3221493*kWh)\r\n'
'1-0:21.7.0*255(000747.85*W)\r\n'
'1-0:41.7.0*255(000737.28*W)\r\n'
'1-0:61.7.0*255(000639.73*W)\r\n'
'1-0:1.7.0*255(002124.86*W)\r\n'
'1-0:96.5.5*255(80)\r\n'
'0-0:96.1.255*255(1ESY1313002565)\r\n'
'!\r\n'
' 25803103\r\n'
'\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\r\n'
)
TELEGRAM_ESY5Q3DA1004_V304 = ( # Easymeter an Wärmepumpe
'/ESY5Q3DA1004 V3.04\r\n'
'\r\n'
'1-0:0.0.0*255(1336001560)\r\n'
'1-0:1.8.0*255(00032549.5061662*kWh)\r\n'
'1-0:21.7.0*255(000557.29*W)\r\n'
'1-0:41.7.0*255(000521.62*W)\r\n'
'1-0:61.7.0*255(000609.30*W)\r\n'
'1-0:1.7.0*255(001688.21*W)\r\n'
'1-0:96.5.5*255(80)\r\n'
'0-0:96.1.255*255(1ESY1336001560)\r\n'
'!\r\n'
' 25818685\r\n'
'DE0000000000000000000000000000003\r\n'
)
+2
View File
@@ -3,6 +3,8 @@ from unittest.mock import Mock
import unittest
from dsmr_parser import obis_references as obis
from dsmr_parser import telegram_specifications
from dsmr_parser.parsers import TelegramParser
from dsmr_parser.clients.protocol import create_dsmr_protocol
+4
View File
@@ -1,9 +1,13 @@
[tox]
envlist = py35,py36,py37,py38,py39
[testenv]
deps=
pytest
pytest-cov
pylama
pytest-asyncio
pytest-catchlog
pytest-mock
commands=
py.test --cov=dsmr_parser test {posargs}