decode latin1 and added ELECTRICITY_EXPORTED_TOTAL

This commit is contained in:
Gunnar Klauberg 2021-11-14 21:49:43 +00:00
parent 4073917d3e
commit df59f3a498
4 changed files with 173 additions and 208 deletions

View File

@ -10,26 +10,23 @@ from dsmr_parser import telegram_specifications
from dsmr_parser.clients.telegram_buffer import TelegramBuffer
from dsmr_parser.exceptions import ParseError, InvalidChecksumError
from dsmr_parser.parsers import TelegramParser
from dsmr_parser.clients.settings import (
SERIAL_SETTINGS_V2_2,
SERIAL_SETTINGS_V4,
SERIAL_SETTINGS_V5,
)
from dsmr_parser.clients.settings import SERIAL_SETTINGS_V2_2, \
SERIAL_SETTINGS_V4, SERIAL_SETTINGS_V5
def create_dsmr_protocol(dsmr_version, telegram_callback, loop=None, **kwargs):
"""Creates a DSMR asyncio protocol."""
if dsmr_version == "2.2":
if dsmr_version == '2.2':
specification = telegram_specifications.V2_2
serial_settings = SERIAL_SETTINGS_V2_2
elif dsmr_version == "4":
elif dsmr_version == '4':
specification = telegram_specifications.V4
serial_settings = SERIAL_SETTINGS_V4
elif dsmr_version == "5":
elif dsmr_version == '5':
specification = telegram_specifications.V5
serial_settings = SERIAL_SETTINGS_V5
elif dsmr_version == "5B":
elif dsmr_version == '5B':
specification = telegram_specifications.BELGIUM_FLUVIUS
serial_settings = SERIAL_SETTINGS_V5
elif dsmr_version == "5L":
@ -42,17 +39,11 @@ def create_dsmr_protocol(dsmr_version, telegram_callback, loop=None, **kwargs):
specification = telegram_specifications.Q3D
serial_settings = SERIAL_SETTINGS_V5
else:
raise NotImplementedError(
"No telegram parser found for version: %s", dsmr_version
)
raise NotImplementedError("No telegram parser found for version: %s",
dsmr_version)
protocol = partial(
DSMRProtocol,
loop,
TelegramParser(specification),
telegram_callback=telegram_callback,
**kwargs
)
protocol = partial(DSMRProtocol, loop, TelegramParser(specification),
telegram_callback=telegram_callback, **kwargs)
return protocol, serial_settings
@ -60,26 +51,22 @@ def create_dsmr_protocol(dsmr_version, telegram_callback, loop=None, **kwargs):
def create_dsmr_reader(port, dsmr_version, telegram_callback, loop=None):
"""Creates a DSMR asyncio protocol coroutine using serial port."""
protocol, serial_settings = create_dsmr_protocol(
dsmr_version, telegram_callback, loop=None
)
serial_settings["url"] = port
dsmr_version, telegram_callback, loop=None)
serial_settings['url'] = port
conn = create_serial_connection(loop, protocol, **serial_settings)
return conn
def create_tcp_dsmr_reader(
host, port, dsmr_version, telegram_callback, loop=None, keep_alive_interval=None
):
def create_tcp_dsmr_reader(host, port, dsmr_version,
telegram_callback, loop=None,
keep_alive_interval=None):
"""Creates a DSMR asyncio protocol coroutine using TCP connection."""
if not loop:
loop = asyncio.get_event_loop()
protocol, _ = create_dsmr_protocol(
dsmr_version,
telegram_callback,
loop=loop,
keep_alive_interval=keep_alive_interval,
)
dsmr_version, telegram_callback, loop=loop,
keep_alive_interval=keep_alive_interval)
conn = loop.create_connection(protocol, host, port)
return conn
@ -90,9 +77,8 @@ class DSMRProtocol(asyncio.Protocol):
transport = None
telegram_callback = None
def __init__(
self, loop, telegram_parser, telegram_callback=None, keep_alive_interval=None
):
def __init__(self, loop, telegram_parser,
telegram_callback=None, keep_alive_interval=None):
"""Initialize class."""
self.loop = loop
self.log = logging.getLogger(__name__)
@ -109,7 +95,7 @@ class DSMRProtocol(asyncio.Protocol):
def connection_made(self, transport):
"""Just logging for now."""
self.transport = transport
self.log.debug("connected")
self.log.debug('connected')
self._active = False
if self.loop and self._keep_alive_interval:
self.loop.call_later(self._keep_alive_interval, self.keep_alive)
@ -118,7 +104,7 @@ class DSMRProtocol(asyncio.Protocol):
"""Add incoming data to buffer."""
data = data.decode("latin1")
self._active = True
self.log.debug("received data: %s", data)
self.log.debug('received data: %s', data)
self.telegram_buffer.append(data)
for telegram in self.telegram_buffer.get_all():
@ -126,26 +112,26 @@ class DSMRProtocol(asyncio.Protocol):
def keep_alive(self):
if self._active:
self.log.debug("keep-alive checked")
self.log.debug('keep-alive checked')
self._active = False
if self.loop:
self.loop.call_later(self._keep_alive_interval, self.keep_alive)
else:
self.log.warning("keep-alive check failed")
self.log.warning('keep-alive check failed')
if self.transport:
self.transport.close()
def connection_lost(self, exc):
"""Stop when connection is lost."""
if exc:
self.log.exception("disconnected due to exception", exc_info=exc)
self.log.exception('disconnected due to exception', exc_info=exc)
else:
self.log.info("disconnected because of close/abort.")
self.log.info('disconnected because of close/abort.')
self._closed.set()
def handle_telegram(self, telegram):
"""Send off parsed telegram to handling callback."""
self.log.debug("got telegram: %s", telegram)
self.log.debug('got telegram: %s', telegram)
try:
parsed_telegram = self.telegram_parser.parse(telegram)

View File

@ -8,57 +8,57 @@ This module contains a mapping of obis references to names.
"""
EN = {
obis.P1_MESSAGE_HEADER: "P1_MESSAGE_HEADER",
obis.P1_MESSAGE_TIMESTAMP: "P1_MESSAGE_TIMESTAMP",
obis.ELECTRICITY_IMPORTED_TOTAL: "ELECTRICITY_IMPORTED_TOTAL",
obis.ELECTRICITY_USED_TARIFF_1: "ELECTRICITY_USED_TARIFF_1",
obis.ELECTRICITY_USED_TARIFF_2: "ELECTRICITY_USED_TARIFF_2",
obis.ELECTRICITY_EXPORTED_TOTAL: "ELECTRICITY_EXPORTED_TOTAL",
obis.ELECTRICITY_DELIVERED_TARIFF_1: "ELECTRICITY_DELIVERED_TARIFF_1",
obis.ELECTRICITY_DELIVERED_TARIFF_2: "ELECTRICITY_DELIVERED_TARIFF_2",
obis.ELECTRICITY_ACTIVE_TARIFF: "ELECTRICITY_ACTIVE_TARIFF",
obis.EQUIPMENT_IDENTIFIER: "EQUIPMENT_IDENTIFIER",
obis.CURRENT_ELECTRICITY_USAGE: "CURRENT_ELECTRICITY_USAGE",
obis.CURRENT_ELECTRICITY_DELIVERY: "CURRENT_ELECTRICITY_DELIVERY",
obis.LONG_POWER_FAILURE_COUNT: "LONG_POWER_FAILURE_COUNT",
obis.SHORT_POWER_FAILURE_COUNT: "SHORT_POWER_FAILURE_COUNT",
obis.POWER_EVENT_FAILURE_LOG: "POWER_EVENT_FAILURE_LOG",
obis.VOLTAGE_SAG_L1_COUNT: "VOLTAGE_SAG_L1_COUNT",
obis.VOLTAGE_SAG_L2_COUNT: "VOLTAGE_SAG_L2_COUNT",
obis.VOLTAGE_SAG_L3_COUNT: "VOLTAGE_SAG_L3_COUNT",
obis.VOLTAGE_SWELL_L1_COUNT: "VOLTAGE_SWELL_L1_COUNT",
obis.VOLTAGE_SWELL_L2_COUNT: "VOLTAGE_SWELL_L2_COUNT",
obis.VOLTAGE_SWELL_L3_COUNT: "VOLTAGE_SWELL_L3_COUNT",
obis.INSTANTANEOUS_VOLTAGE_L1: "INSTANTANEOUS_VOLTAGE_L1",
obis.INSTANTANEOUS_VOLTAGE_L2: "INSTANTANEOUS_VOLTAGE_L2",
obis.INSTANTANEOUS_VOLTAGE_L3: "INSTANTANEOUS_VOLTAGE_L3",
obis.INSTANTANEOUS_CURRENT_L1: "INSTANTANEOUS_CURRENT_L1",
obis.INSTANTANEOUS_CURRENT_L2: "INSTANTANEOUS_CURRENT_L2",
obis.INSTANTANEOUS_CURRENT_L3: "INSTANTANEOUS_CURRENT_L3",
obis.TEXT_MESSAGE_CODE: "TEXT_MESSAGE_CODE",
obis.TEXT_MESSAGE: "TEXT_MESSAGE",
obis.DEVICE_TYPE: "DEVICE_TYPE",
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: "INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE",
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: "INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE",
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: "INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE",
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: "INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE",
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: "INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE",
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: "INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE",
obis.EQUIPMENT_IDENTIFIER_GAS: "EQUIPMENT_IDENTIFIER_GAS",
obis.HOURLY_GAS_METER_READING: "HOURLY_GAS_METER_READING",
obis.GAS_METER_READING: "GAS_METER_READING",
obis.ACTUAL_TRESHOLD_ELECTRICITY: "ACTUAL_TRESHOLD_ELECTRICITY",
obis.ACTUAL_SWITCH_POSITION: "ACTUAL_SWITCH_POSITION",
obis.VALVE_POSITION_GAS: "VALVE_POSITION_GAS",
obis.BELGIUM_HOURLY_GAS_METER_READING: "BELGIUM_HOURLY_GAS_METER_READING",
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: "LUXEMBOURG_EQUIPMENT_IDENTIFIER",
obis.LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL: "LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL",
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: "LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL",
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: "SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL",
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: "SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL",
obis.Q3D_EQUIPMENT_IDENTIFIER: "Q3D_EQUIPMENT_IDENTIFIER",
obis.Q3D_EQUIPMENT_STATE: "Q3D_EQUIPMENT_STATE",
obis.Q3D_EQUIPMENT_SERIALNUMBER: "Q3D_EQUIPMENT_SERIALNUMBER",
obis.P1_MESSAGE_HEADER: 'P1_MESSAGE_HEADER',
obis.P1_MESSAGE_TIMESTAMP: 'P1_MESSAGE_TIMESTAMP',
obis.ELECTRICITY_IMPORTED_TOTAL: 'ELECTRICITY_IMPORTED_TOTAL',
obis.ELECTRICITY_USED_TARIFF_1: 'ELECTRICITY_USED_TARIFF_1',
obis.ELECTRICITY_USED_TARIFF_2: 'ELECTRICITY_USED_TARIFF_2',
obis.ELECTRICITY_EXPORTED_TOTAL: 'ELECTRICITY_EXPORTED_TOTAL',
obis.ELECTRICITY_DELIVERED_TARIFF_1: 'ELECTRICITY_DELIVERED_TARIFF_1',
obis.ELECTRICITY_DELIVERED_TARIFF_2: 'ELECTRICITY_DELIVERED_TARIFF_2',
obis.ELECTRICITY_ACTIVE_TARIFF: 'ELECTRICITY_ACTIVE_TARIFF',
obis.EQUIPMENT_IDENTIFIER: 'EQUIPMENT_IDENTIFIER',
obis.CURRENT_ELECTRICITY_USAGE: 'CURRENT_ELECTRICITY_USAGE',
obis.CURRENT_ELECTRICITY_DELIVERY: 'CURRENT_ELECTRICITY_DELIVERY',
obis.LONG_POWER_FAILURE_COUNT: 'LONG_POWER_FAILURE_COUNT',
obis.SHORT_POWER_FAILURE_COUNT: 'SHORT_POWER_FAILURE_COUNT',
obis.POWER_EVENT_FAILURE_LOG: 'POWER_EVENT_FAILURE_LOG',
obis.VOLTAGE_SAG_L1_COUNT: 'VOLTAGE_SAG_L1_COUNT',
obis.VOLTAGE_SAG_L2_COUNT: 'VOLTAGE_SAG_L2_COUNT',
obis.VOLTAGE_SAG_L3_COUNT: 'VOLTAGE_SAG_L3_COUNT',
obis.VOLTAGE_SWELL_L1_COUNT: 'VOLTAGE_SWELL_L1_COUNT',
obis.VOLTAGE_SWELL_L2_COUNT: 'VOLTAGE_SWELL_L2_COUNT',
obis.VOLTAGE_SWELL_L3_COUNT: 'VOLTAGE_SWELL_L3_COUNT',
obis.INSTANTANEOUS_VOLTAGE_L1: 'INSTANTANEOUS_VOLTAGE_L1',
obis.INSTANTANEOUS_VOLTAGE_L2: 'INSTANTANEOUS_VOLTAGE_L2',
obis.INSTANTANEOUS_VOLTAGE_L3: 'INSTANTANEOUS_VOLTAGE_L3',
obis.INSTANTANEOUS_CURRENT_L1: 'INSTANTANEOUS_CURRENT_L1',
obis.INSTANTANEOUS_CURRENT_L2: 'INSTANTANEOUS_CURRENT_L2',
obis.INSTANTANEOUS_CURRENT_L3: 'INSTANTANEOUS_CURRENT_L3',
obis.TEXT_MESSAGE_CODE: 'TEXT_MESSAGE_CODE',
obis.TEXT_MESSAGE: 'TEXT_MESSAGE',
obis.DEVICE_TYPE: 'DEVICE_TYPE',
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: 'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE',
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: 'INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE',
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: 'INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE',
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: 'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE',
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: 'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE',
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: 'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE',
obis.EQUIPMENT_IDENTIFIER_GAS: 'EQUIPMENT_IDENTIFIER_GAS',
obis.HOURLY_GAS_METER_READING: 'HOURLY_GAS_METER_READING',
obis.GAS_METER_READING: 'GAS_METER_READING',
obis.ACTUAL_TRESHOLD_ELECTRICITY: 'ACTUAL_TRESHOLD_ELECTRICITY',
obis.ACTUAL_SWITCH_POSITION: 'ACTUAL_SWITCH_POSITION',
obis.VALVE_POSITION_GAS: 'VALVE_POSITION_GAS',
obis.BELGIUM_HOURLY_GAS_METER_READING: 'BELGIUM_HOURLY_GAS_METER_READING',
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: 'LUXEMBOURG_EQUIPMENT_IDENTIFIER',
obis.LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL: 'LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL',
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL',
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
obis.Q3D_EQUIPMENT_IDENTIFIER: 'Q3D_EQUIPMENT_IDENTIFIER',
obis.Q3D_EQUIPMENT_STATE: 'Q3D_EQUIPMENT_STATE',
obis.Q3D_EQUIPMENT_SERIALNUMBER: 'Q3D_EQUIPMENT_SERIALNUMBER',
}
REVERSE_EN = dict([(v, k) for k, v in EN.items()])

View File

@ -6,76 +6,69 @@ refactored to full line signatures to maintain backwards compatibility.
Might be refactored in a backwards incompatible way as soon as proper telegram
objects are introduced.
"""
P1_MESSAGE_HEADER = r"\d-\d:0\.2\.8.+?\r\n"
P1_MESSAGE_TIMESTAMP = r"\d-\d:1\.0\.0.+?\r\n"
ELECTRICITY_IMPORTED_TOTAL = r"\d-\d:1\.8\.0.+?\r\n"
ELECTRICITY_USED_TARIFF_1 = r"\d-\d:1\.8\.1.+?\r\n"
ELECTRICITY_USED_TARIFF_2 = r"\d-\d:1\.8\.2.+?\r\n"
ELECTRICITY_EXPORTED_TOTAL = r"\d-\d:2\.8\.0.+?\r\n"
ELECTRICITY_DELIVERED_TARIFF_1 = r"\d-\d:2\.8\.1.+?\r\n"
ELECTRICITY_DELIVERED_TARIFF_2 = r"\d-\d:2\.8\.2.+?\r\n"
ELECTRICITY_ACTIVE_TARIFF = r"\d-\d:96\.14\.0.+?\r\n"
EQUIPMENT_IDENTIFIER = r"\d-\d:96\.1\.1.+?\r\n"
CURRENT_ELECTRICITY_USAGE = r"\d-\d:1\.7\.0.+?\r\n"
CURRENT_ELECTRICITY_DELIVERY = r"\d-\d:2\.7\.0.+?\r\n"
LONG_POWER_FAILURE_COUNT = r"96\.7\.9.+?\r\n"
SHORT_POWER_FAILURE_COUNT = r"96\.7\.21.+?\r\n"
POWER_EVENT_FAILURE_LOG = r"99\.97\.0.+?\r\n"
VOLTAGE_SAG_L1_COUNT = r"\d-\d:32\.32\.0.+?\r\n"
VOLTAGE_SAG_L2_COUNT = r"\d-\d:52\.32\.0.+?\r\n"
VOLTAGE_SAG_L3_COUNT = r"\d-\d:72\.32\.0.+?\r\n"
VOLTAGE_SWELL_L1_COUNT = r"\d-\d:32\.36\.0.+?\r\n"
VOLTAGE_SWELL_L2_COUNT = r"\d-\d:52\.36\.0.+?\r\n"
VOLTAGE_SWELL_L3_COUNT = r"\d-\d:72\.36\.0.+?\r\n"
INSTANTANEOUS_VOLTAGE_L1 = r"\d-\d:32\.7\.0.+?\r\n"
INSTANTANEOUS_VOLTAGE_L2 = r"\d-\d:52\.7\.0.+?\r\n"
INSTANTANEOUS_VOLTAGE_L3 = r"\d-\d:72\.7\.0.+?\r\n"
INSTANTANEOUS_CURRENT_L1 = r"\d-\d:31\.7\.0.+?\r\n"
INSTANTANEOUS_CURRENT_L2 = r"\d-\d:51\.7\.0.+?\r\n"
INSTANTANEOUS_CURRENT_L3 = r"\d-\d:71\.7\.0.+?\r\n"
TEXT_MESSAGE_CODE = r"\d-\d:96\.13\.1.+?\r\n"
TEXT_MESSAGE = r"\d-\d:96\.13\.0.+?\r\n"
DEVICE_TYPE = r"\d-\d:24\.1\.0.+?\r\n"
INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE = r"\d-\d:21\.7\.0.+?\r\n"
INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE = r"\d-\d:41\.7\.0.+?\r\n"
INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE = r"\d-\d:61\.7\.0.+?\r\n"
INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r"\d-\d:22\.7\.0.+?\r\n"
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r"\d-\d:42\.7\.0.+?\r\n"
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r"\d-\d:62\.7\.0.+?\r\n"
EQUIPMENT_IDENTIFIER_GAS = r"\d-\d:96\.1\.0.+?\r\n"
P1_MESSAGE_HEADER = r'\d-\d:0\.2\.8.+?\r\n'
P1_MESSAGE_TIMESTAMP = r'\d-\d:1\.0\.0.+?\r\n'
ELECTRICITY_IMPORTED_TOTAL = r'\d-\d:1\.8\.0.+?\r\n'
ELECTRICITY_USED_TARIFF_1 = r'\d-\d:1\.8\.1.+?\r\n'
ELECTRICITY_USED_TARIFF_2 = r'\d-\d:1\.8\.2.+?\r\n'
ELECTRICITY_EXPORTED_TOTAL = r'\d-\d:2\.8\.0.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_1 = r'\d-\d:2\.8\.1.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_2 = r'\d-\d:2\.8\.2.+?\r\n'
ELECTRICITY_ACTIVE_TARIFF = r'\d-\d:96\.14\.0.+?\r\n'
EQUIPMENT_IDENTIFIER = r'\d-\d:96\.1\.1.+?\r\n'
CURRENT_ELECTRICITY_USAGE = r'\d-\d:1\.7\.0.+?\r\n'
CURRENT_ELECTRICITY_DELIVERY = r'\d-\d:2\.7\.0.+?\r\n'
LONG_POWER_FAILURE_COUNT = r'96\.7\.9.+?\r\n'
SHORT_POWER_FAILURE_COUNT = r'96\.7\.21.+?\r\n'
POWER_EVENT_FAILURE_LOG = r'99\.97\.0.+?\r\n'
VOLTAGE_SAG_L1_COUNT = r'\d-\d:32\.32\.0.+?\r\n'
VOLTAGE_SAG_L2_COUNT = r'\d-\d:52\.32\.0.+?\r\n'
VOLTAGE_SAG_L3_COUNT = r'\d-\d:72\.32\.0.+?\r\n'
VOLTAGE_SWELL_L1_COUNT = r'\d-\d:32\.36\.0.+?\r\n'
VOLTAGE_SWELL_L2_COUNT = r'\d-\d:52\.36\.0.+?\r\n'
VOLTAGE_SWELL_L3_COUNT = r'\d-\d:72\.36\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L1 = r'\d-\d:32\.7\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L2 = r'\d-\d:52\.7\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L3 = r'\d-\d:72\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L1 = r'\d-\d:31\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L2 = r'\d-\d:51\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L3 = r'\d-\d:71\.7\.0.+?\r\n'
TEXT_MESSAGE_CODE = r'\d-\d:96\.13\.1.+?\r\n'
TEXT_MESSAGE = r'\d-\d:96\.13\.0.+?\r\n'
DEVICE_TYPE = r'\d-\d:24\.1\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE = r'\d-\d:21\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE = r'\d-\d:41\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE = r'\d-\d:61\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r'\d-\d:22\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r'\d-\d:42\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r'\d-\d:62\.7\.0.+?\r\n'
EQUIPMENT_IDENTIFIER_GAS = r'\d-\d:96\.1\.0.+?\r\n'
# TODO differences between gas meter readings in v3 and lower and v4 and up
HOURLY_GAS_METER_READING = r"\d-\d:24\.2\.1.+?\r\n"
GAS_METER_READING = r"\d-\d:24\.3\.0.+?\r\n.+?\r\n"
ACTUAL_TRESHOLD_ELECTRICITY = r"\d-\d:17\.0\.0.+?\r\n"
ACTUAL_SWITCH_POSITION = r"\d-\d:96\.3\.10.+?\r\n"
VALVE_POSITION_GAS = r"\d-\d:24\.4\.0.+?\r\n"
HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.1.+?\r\n'
GAS_METER_READING = r'\d-\d:24\.3\.0.+?\r\n.+?\r\n'
ACTUAL_TRESHOLD_ELECTRICITY = r'\d-\d:17\.0\.0.+?\r\n'
ACTUAL_SWITCH_POSITION = r'\d-\d:96\.3\.10.+?\r\n'
VALVE_POSITION_GAS = r'\d-\d:24\.4\.0.+?\r\n'
# TODO 17.0.0
# TODO 96.3.10
ELECTRICITY_USED_TARIFF_ALL = (ELECTRICITY_USED_TARIFF_1, ELECTRICITY_USED_TARIFF_2)
ELECTRICITY_USED_TARIFF_ALL = (
ELECTRICITY_USED_TARIFF_1,
ELECTRICITY_USED_TARIFF_2
)
ELECTRICITY_DELIVERED_TARIFF_ALL = (
ELECTRICITY_DELIVERED_TARIFF_1,
ELECTRICITY_DELIVERED_TARIFF_2,
ELECTRICITY_DELIVERED_TARIFF_2
)
# Alternate codes for foreign countries.
BELGIUM_HOURLY_GAS_METER_READING = (
r"\d-\d:24\.2\.3.+?\r\n" # Different code, same format.
)
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r"\d-\d:42\.0\.0.+?\r\n" # Logical device name
LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL = (
r"\d-\d:1\.8\.0.+?\r\n" # Total imported energy register (P+)
)
LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = (
r"\d-\d:2\.8\.0.+?\r\n" # Total exported energy register (P-)
)
SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL = (
r"\d-\d:1\.8\.0.+?\r\n" # Total imported energy register (P+)
)
SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = (
r"\d-\d:2\.8\.0.+?\r\n" # Total exported energy register (P-)
)
Q3D_EQUIPMENT_IDENTIFIER = r"\d-\d:0\.0\.0.+?\r\n" # Logical device name
Q3D_EQUIPMENT_STATE = r"\d-\d:96\.5\.5.+?\r\n" # Device state (hexadecimal)
Q3D_EQUIPMENT_SERIALNUMBER = r"\d-\d:96\.1\.255.+?\r\n" # Device Serialnumber
BELGIUM_HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.3.+?\r\n' # Different code, same format.
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'\d-\d:42\.0\.0.+?\r\n' # Logical device name
LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
Q3D_EQUIPMENT_IDENTIFIER = r'\d-\d:0\.0\.0.+?\r\n' # Logical device name
Q3D_EQUIPMENT_STATE = r'\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal)
Q3D_EQUIPMENT_SERIALNUMBER = r'\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber

View File

@ -2,18 +2,9 @@ from decimal import Decimal
from copy import deepcopy
from dsmr_parser import obis_references as obis
from dsmr_parser.parsers import (
CosemParser,
ValueParser,
MBusParser,
ProfileGenericParser,
)
from dsmr_parser.parsers import CosemParser, ValueParser, MBusParser, ProfileGenericParser
from dsmr_parser.value_types import timestamp
from dsmr_parser.profile_generic_specifications import (
BUFFER_TYPES,
PG_HEAD_PARSERS,
PG_UNIDENTIFIED_BUFFERTYPE_PARSERS,
)
from dsmr_parser.profile_generic_specifications import BUFFER_TYPES, PG_HEAD_PARSERS, PG_UNIDENTIFIED_BUFFERTYPE_PARSERS
"""
dsmr_parser.telegram_specifications
@ -24,8 +15,8 @@ how the telegram lines are parsed.
"""
V2_2 = {
"checksum_support": False,
"objects": {
'checksum_support': False,
'objects': {
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
@ -50,14 +41,14 @@ V2_2 = {
ValueParser(str), # unit, position 5
ValueParser(Decimal), # meter reading, position 6
),
},
}
}
V3 = V2_2
V4 = {
"checksum_support": True,
"objects": {
'checksum_support': True,
'objects': {
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
@ -70,9 +61,10 @@ V4 = {
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.SHORT_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
obis.POWER_EVENT_FAILURE_LOG: ProfileGenericParser(
BUFFER_TYPES, PG_HEAD_PARSERS, PG_UNIDENTIFIED_BUFFERTYPE_PARSERS
),
obis.POWER_EVENT_FAILURE_LOG:
ProfileGenericParser(BUFFER_TYPES,
PG_HEAD_PARSERS,
PG_UNIDENTIFIED_BUFFERTYPE_PARSERS),
obis.VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SAG_L3_COUNT: CosemParser(ValueParser(int)),
@ -93,14 +85,15 @@ V4 = {
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
obis.HOURLY_GAS_METER_READING: MBusParser(
ValueParser(timestamp), ValueParser(Decimal)
),
},
ValueParser(timestamp),
ValueParser(Decimal)
)
}
}
V5 = {
"checksum_support": True,
"objects": {
'checksum_support': True,
'objects': {
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
@ -114,9 +107,10 @@ V5 = {
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
obis.SHORT_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
obis.POWER_EVENT_FAILURE_LOG: ProfileGenericParser(
BUFFER_TYPES, PG_HEAD_PARSERS, PG_UNIDENTIFIED_BUFFERTYPE_PARSERS
),
obis.POWER_EVENT_FAILURE_LOG:
ProfileGenericParser(BUFFER_TYPES,
PG_HEAD_PARSERS,
PG_UNIDENTIFIED_BUFFERTYPE_PARSERS),
obis.VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SAG_L3_COUNT: CosemParser(ValueParser(int)),
@ -139,46 +133,38 @@ V5 = {
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
obis.HOURLY_GAS_METER_READING: MBusParser(
ValueParser(timestamp), ValueParser(Decimal)
),
},
ValueParser(timestamp),
ValueParser(Decimal)
)
}
}
ALL = (V2_2, V3, V4, V5)
BELGIUM_FLUVIUS = deepcopy(V5)
BELGIUM_FLUVIUS["objects"].update(
{
BELGIUM_FLUVIUS['objects'].update({
obis.BELGIUM_HOURLY_GAS_METER_READING: MBusParser(
ValueParser(timestamp), ValueParser(Decimal)
ValueParser(timestamp),
ValueParser(Decimal)
)
}
)
})
LUXEMBOURG_SMARTY = deepcopy(V5)
LUXEMBOURG_SMARTY["objects"].update(
{
LUXEMBOURG_SMARTY['objects'].update({
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL: CosemParser(
ValueParser(Decimal)
),
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: CosemParser(
ValueParser(Decimal)
),
}
)
obis.LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
})
# Source: https://www.energiforetagen.se/globalassets/energiforetagen/det-erbjuder-vi/kurser-och-konferenser/elnat/branschrekommendation-lokalt-granssnitt-v2_0-201912.pdf
SWEDEN = {
"checksum_support": True,
"objects": {
'checksum_support': True,
'objects': {
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: CosemParser(
ValueParser(Decimal)
),
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
@ -193,7 +179,7 @@ SWEDEN = {
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
},
}
}
Q3D = {