Change DSMR 5 and 5B to use DSMR devices (#142)

At least the BE and the NL DSMR devices use MBUS.
Therefore we make the MBUS obis reference generic, and convert the V5
telegram to use MBUS values.

Finally set self.maxDiff = None to have a full test output on some
tests.
This commit is contained in:
dupondje
2024-03-07 11:21:23 +01:00
committed by GitHub
parent fcbcbb30e0
commit bc35a051f2
7 changed files with 190 additions and 316 deletions
+21 -21
View File
@@ -15,59 +15,59 @@ class MbusDeviceTest(unittest.TestCase):
device_type_parser = [
object["value_parser"]
for object in v5_objects
if object["obis_reference"] == obis_references.DEVICE_TYPE
if object["obis_reference"] == obis_references.MBUS_DEVICE_TYPE
][0]
device_type = device_type_parser.parse('0-2:24.1.0(003)\r\n')
equipment_parser = [
object["value_parser"]
for object in v5_objects
if object["obis_reference"] == obis_references.EQUIPMENT_IDENTIFIER_GAS
if object["obis_reference"] == obis_references.MBUS_EQUIPMENT_IDENTIFIER
][0]
equipment = equipment_parser.parse('0-2:96.1.0(4730303339303031393336393930363139)\r\n')
gas_reading_parser = [
object["value_parser"]
for object in v5_objects
if object["obis_reference"] == obis_references.HOURLY_GAS_METER_READING
if object["obis_reference"] == obis_references.MBUS_METER_READING
][0]
gas_reading = gas_reading_parser.parse('0-2:24.2.1(200426223001S)(00246.138*m3)\r\n')
mbus_device = MbusDevice(channel_id=1)
mbus_device.add(obis_references.DEVICE_TYPE, device_type, "DEVICE_TYPE")
mbus_device.add(obis_references.EQUIPMENT_IDENTIFIER_GAS, equipment, "EQUIPMENT_IDENTIFIER_GAS")
mbus_device.add(obis_references.HOURLY_GAS_METER_READING, gas_reading, "HOURLY_GAS_METER_READING")
mbus_device = MbusDevice(channel_id=2)
mbus_device.add(obis_references.MBUS_DEVICE_TYPE, device_type, "MBUS_DEVICE_TYPE")
mbus_device.add(obis_references.MBUS_EQUIPMENT_IDENTIFIER, equipment, "MBUS_EQUIPMENT_IDENTIFIER")
mbus_device.add(obis_references.MBUS_METER_READING, gas_reading, "MBUS_METER_READING")
self.mbus_device = mbus_device
def test_attributes(self):
self.assertEqual(self.mbus_device.DEVICE_TYPE.value, 3)
self.assertEqual(self.mbus_device.DEVICE_TYPE.unit, None)
self.assertEqual(self.mbus_device.MBUS_DEVICE_TYPE.value, 3)
self.assertEqual(self.mbus_device.MBUS_DEVICE_TYPE.unit, None)
self.assertEqual(self.mbus_device.EQUIPMENT_IDENTIFIER_GAS.value,
self.assertEqual(self.mbus_device.MBUS_EQUIPMENT_IDENTIFIER.value,
'4730303339303031393336393930363139')
self.assertEqual(self.mbus_device.EQUIPMENT_IDENTIFIER_GAS.unit, None)
self.assertEqual(self.mbus_device.MBUS_EQUIPMENT_IDENTIFIER.unit, None)
self.assertEqual(self.mbus_device.HOURLY_GAS_METER_READING.value, Decimal('246.138'))
self.assertEqual(self.mbus_device.HOURLY_GAS_METER_READING.unit, 'm3')
self.assertEqual(self.mbus_device.MBUS_METER_READING.value, Decimal('246.138'))
self.assertEqual(self.mbus_device.MBUS_METER_READING.unit, 'm3')
def test_to_json(self):
self.assertEqual(
json.loads(self.mbus_device.to_json()),
{
'CHANNEL_ID': 1,
'DEVICE_TYPE': {'value': 3, 'unit': None},
'EQUIPMENT_IDENTIFIER_GAS': {'value': '4730303339303031393336393930363139', 'unit': None},
'HOURLY_GAS_METER_READING': {'datetime': '2020-04-26T20:30:01+00:00', 'value': 246.138, 'unit': 'm3'}}
'CHANNEL_ID': 2,
'MBUS_DEVICE_TYPE': {'value': 3, 'unit': None},
'MBUS_EQUIPMENT_IDENTIFIER': {'value': '4730303339303031393336393930363139', 'unit': None},
'MBUS_METER_READING': {'datetime': '2020-04-26T20:30:01+00:00', 'value': 246.138, 'unit': 'm3'}}
)
def test_str(self):
self.assertEqual(
str(self.mbus_device),
(
'MBUS DEVICE (channel 1)\n'
'\tDEVICE_TYPE: 3 [None]\n'
'\tEQUIPMENT_IDENTIFIER_GAS: 4730303339303031393336393930363139 [None]\n'
'\tHOURLY_GAS_METER_READING: 246.138 [m3] at 2020-04-26T20:30:01+00:00\n'
'MBUS DEVICE (channel 2)\n'
'\tMBUS_DEVICE_TYPE: 3 [None]\n'
'\tMBUS_EQUIPMENT_IDENTIFIER: 4730303339303031393336393930363139 [None]\n'
'\tMBUS_METER_READING: 246.138 [m3] at 2020-04-26T20:30:01+00:00\n'
)
)
+41 -44
View File
@@ -216,14 +216,6 @@ class TelegramTest(unittest.TestCase):
value_type=Decimal,
value_val=Decimal('2'))
# DEVICE_TYPE (0-x:24.1.0)
self.verify_telegram_item(telegram,
'DEVICE_TYPE',
object_type=CosemObject,
unit_val=None,
value_type=int,
value_val=3)
# INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE (1-0:21.7.0)
self.verify_telegram_item(telegram,
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE',
@@ -272,7 +264,15 @@ class TelegramTest(unittest.TestCase):
value_type=Decimal,
value_val=Decimal('0'))
# EQUIPMENT_IDENTIFIER_GAS (0-x:96.1.0)
# DEVICE_TYPE (0-1:24.1.0)
self.verify_telegram_item(telegram,
'DEVICE_TYPE',
object_type=CosemObject,
unit_val=None,
value_type=int,
value_val=3)
# EQUIPMENT_IDENTIFIER_GAS (0-1:96.1.0)
self.verify_telegram_item(telegram,
'EQUIPMENT_IDENTIFIER_GAS',
object_type=CosemObject,
@@ -340,28 +340,28 @@ class TelegramTest(unittest.TestCase):
self.assertEqual(len(mbus_devices), 2)
mbus_device_1 = mbus_devices[0]
self.assertEqual(mbus_device_1.DEVICE_TYPE.value, 3)
self.assertEqual(mbus_device_1.EQUIPMENT_IDENTIFIER_GAS.value, None)
self.assertEqual(mbus_device_1.HOURLY_GAS_METER_READING.value, Decimal('0'))
self.assertEqual(mbus_device_1.MBUS_DEVICE_TYPE.value, 3)
self.assertEqual(mbus_device_1.MBUS_EQUIPMENT_IDENTIFIER.value, None)
self.assertEqual(mbus_device_1.MBUS_METER_READING.value, Decimal('0'))
mbus_device_2 = mbus_devices[1]
self.assertEqual(mbus_device_2.DEVICE_TYPE.value, 3)
self.assertEqual(mbus_device_2.EQUIPMENT_IDENTIFIER_GAS.value, '4730303339303031393336393930363139')
self.assertEqual(mbus_device_2.HOURLY_GAS_METER_READING.value, Decimal('246.138'))
self.assertEqual(mbus_device_2.MBUS_DEVICE_TYPE.value, 3)
self.assertEqual(mbus_device_2.MBUS_EQUIPMENT_IDENTIFIER.value, '4730303339303031393336393930363139')
self.assertEqual(mbus_device_2.MBUS_METER_READING.value, Decimal('246.138'))
def test_get_mbus_device_by_channel(self):
parser = TelegramParser(telegram_specifications.V5)
telegram = parser.parse(TELEGRAM_V5_TWO_MBUS)
mbus_device_1 = telegram.get_mbus_device_by_channel(1)
self.assertEqual(mbus_device_1.DEVICE_TYPE.value, 3)
self.assertEqual(mbus_device_1.EQUIPMENT_IDENTIFIER_GAS.value, None)
self.assertEqual(mbus_device_1.HOURLY_GAS_METER_READING.value, Decimal('0'))
self.assertEqual(mbus_device_1.MBUS_DEVICE_TYPE.value, 3)
self.assertEqual(mbus_device_1.MBUS_EQUIPMENT_IDENTIFIER.value, None)
self.assertEqual(mbus_device_1.MBUS_METER_READING.value, Decimal('0'))
mbus_device_2 = telegram.get_mbus_device_by_channel(2)
self.assertEqual(mbus_device_2.DEVICE_TYPE.value, 3)
self.assertEqual(mbus_device_2.EQUIPMENT_IDENTIFIER_GAS.value, '4730303339303031393336393930363139')
self.assertEqual(mbus_device_2.HOURLY_GAS_METER_READING.value, Decimal('246.138'))
self.assertEqual(mbus_device_2.MBUS_DEVICE_TYPE.value, 3)
self.assertEqual(mbus_device_2.MBUS_EQUIPMENT_IDENTIFIER.value, '4730303339303031393336393930363139')
self.assertEqual(mbus_device_2.MBUS_METER_READING.value, Decimal('246.138'))
def test_without_mbus_devices(self):
parser = TelegramParser(telegram_specifications.V5, apply_checksum_validation=False)
@@ -375,11 +375,12 @@ class TelegramTest(unittest.TestCase):
telegram = parser.parse(TELEGRAM_V5)
json_data = json.loads(telegram.to_json())
self.maxDiff = None
self.assertEqual(
json_data,
{'CURRENT_ELECTRICITY_DELIVERY': {'unit': 'kW', 'value': 0.0},
'CURRENT_ELECTRICITY_USAGE': {'unit': 'kW', 'value': 0.244},
'DEVICE_TYPE': {'unit': None, 'value': 3},
'ELECTRICITY_ACTIVE_TARIFF': {'unit': None, 'value': '0002'},
'ELECTRICITY_DELIVERED_TARIFF_1': {'unit': 'kWh', 'value': 2.444},
'ELECTRICITY_DELIVERED_TARIFF_2': {'unit': 'kWh', 'value': 0.0},
@@ -387,10 +388,6 @@ class TelegramTest(unittest.TestCase):
'ELECTRICITY_USED_TARIFF_2': {'unit': 'kWh', 'value': 2.399},
'EQUIPMENT_IDENTIFIER': {'unit': None,
'value': '4B384547303034303436333935353037'},
'EQUIPMENT_IDENTIFIER_GAS': {'unit': None, 'value': None},
'HOURLY_GAS_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00',
'unit': 'm3',
'value': 0.107},
'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE': {'unit': 'kW', 'value': 0.0},
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE': {'unit': 'kW', 'value': 0.07},
'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE': {'unit': 'kW', 'value': 0.0},
@@ -405,15 +402,16 @@ class TelegramTest(unittest.TestCase):
'INSTANTANEOUS_VOLTAGE_L3': {'unit': 'V', 'value': 229.0},
'LONG_POWER_FAILURE_COUNT': {'unit': None, 'value': 0},
'MBUS_DEVICES': [{'CHANNEL_ID': 1,
'DEVICE_TYPE': {'unit': None, 'value': 3},
'EQUIPMENT_IDENTIFIER_GAS': {'unit': None,
'value': '3232323241424344313233343536373839'},
'HOURLY_GAS_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00',
'unit': 'm3',
'value': 0.107}},
'MBUS_DEVICE_TYPE': {'unit': None, 'value': 3},
'MBUS_EQUIPMENT_IDENTIFIER': {'unit': None,
'value': '3232323241424344313233343536373839'},
'MBUS_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00',
'unit': 'm3',
'value': 0.107}},
{'CHANNEL_ID': 2,
'DEVICE_TYPE': {'unit': None, 'value': 3},
'EQUIPMENT_IDENTIFIER_GAS': {'unit': None, 'value': None}}],
'MBUS_DEVICE_TYPE': {'unit': None, 'value': 3},
'MBUS_EQUIPMENT_IDENTIFIER': {'unit': None,
'value': None}}],
'P1_MESSAGE_HEADER': {'unit': None, 'value': '50'},
'P1_MESSAGE_TIMESTAMP': {'unit': None, 'value': '2017-01-02T18:20:02+00:00'},
'POWER_EVENT_FAILURE_LOG': {'buffer': [],
@@ -433,6 +431,8 @@ class TelegramTest(unittest.TestCase):
parser = TelegramParser(telegram_specifications.V5)
telegram = parser.parse(TELEGRAM_V5)
self.maxDiff = None
self.assertEqual(
str(telegram),
(
@@ -463,22 +463,19 @@ class TelegramTest(unittest.TestCase):
'INSTANTANEOUS_CURRENT_L2: 0.44 [A]\n'
'INSTANTANEOUS_CURRENT_L3: 0.86 [A]\n'
'TEXT_MESSAGE: None [None]\n'
'DEVICE_TYPE: 3 [None]\n'
'MBUS DEVICE (channel 1)\n'
' DEVICE_TYPE: 3 [None]\n'
' EQUIPMENT_IDENTIFIER_GAS: 3232323241424344313233343536373839 [None]\n'
' HOURLY_GAS_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n'
'MBUS DEVICE (channel 2)\n'
' DEVICE_TYPE: 3 [None]\n'
' EQUIPMENT_IDENTIFIER_GAS: None [None]\n'
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: 0.070 [kW]\n'
'INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: 0.032 [kW]\n'
'INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: 0.142 [kW]\n'
'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: 0.000 [kW]\n'
'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: 0.000 [kW]\n'
'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: 0.000 [kW]\n'
'EQUIPMENT_IDENTIFIER_GAS: None [None]\n'
'HOURLY_GAS_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n'
'MBUS DEVICE (channel 1)\n'
' MBUS_DEVICE_TYPE: 3 [None]\n'
' MBUS_EQUIPMENT_IDENTIFIER: 3232323241424344313233343536373839 [None]\n'
' MBUS_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n'
'MBUS DEVICE (channel 2)\n'
' MBUS_DEVICE_TYPE: 3 [None]\n'
' MBUS_EQUIPMENT_IDENTIFIER: None [None]\n'
)
)