Merge pull request #96 from lowdef/master
resolve name clash as reported in issue #95
This commit is contained in:
commit
b562510e40
@ -22,7 +22,6 @@ class SocketReader(object):
|
|||||||
self.telegram_buffer = TelegramBuffer()
|
self.telegram_buffer = TelegramBuffer()
|
||||||
self.telegram_specification = telegram_specification
|
self.telegram_specification = telegram_specification
|
||||||
|
|
||||||
|
|
||||||
def read(self):
|
def read(self):
|
||||||
"""
|
"""
|
||||||
Read complete DSMR telegram's from remote interface and parse it
|
Read complete DSMR telegram's from remote interface and parse it
|
||||||
|
@ -52,10 +52,6 @@ EN = {
|
|||||||
obis.VALVE_POSITION_GAS: 'VALVE_POSITION_GAS',
|
obis.VALVE_POSITION_GAS: 'VALVE_POSITION_GAS',
|
||||||
obis.BELGIUM_HOURLY_GAS_METER_READING: 'BELGIUM_HOURLY_GAS_METER_READING',
|
obis.BELGIUM_HOURLY_GAS_METER_READING: 'BELGIUM_HOURLY_GAS_METER_READING',
|
||||||
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: 'LUXEMBOURG_EQUIPMENT_IDENTIFIER',
|
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: 'LUXEMBOURG_EQUIPMENT_IDENTIFIER',
|
||||||
obis.LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL: 'LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL',
|
|
||||||
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
|
|
||||||
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL',
|
|
||||||
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
|
|
||||||
obis.Q3D_EQUIPMENT_IDENTIFIER: 'Q3D_EQUIPMENT_IDENTIFIER',
|
obis.Q3D_EQUIPMENT_IDENTIFIER: 'Q3D_EQUIPMENT_IDENTIFIER',
|
||||||
obis.Q3D_EQUIPMENT_STATE: 'Q3D_EQUIPMENT_STATE',
|
obis.Q3D_EQUIPMENT_STATE: 'Q3D_EQUIPMENT_STATE',
|
||||||
obis.Q3D_EQUIPMENT_SERIALNUMBER: 'Q3D_EQUIPMENT_SERIALNUMBER',
|
obis.Q3D_EQUIPMENT_SERIALNUMBER: 'Q3D_EQUIPMENT_SERIALNUMBER',
|
||||||
|
@ -8,10 +8,8 @@ objects are introduced.
|
|||||||
"""
|
"""
|
||||||
P1_MESSAGE_HEADER = r'\d-\d:0\.2\.8.+?\r\n'
|
P1_MESSAGE_HEADER = r'\d-\d:0\.2\.8.+?\r\n'
|
||||||
P1_MESSAGE_TIMESTAMP = r'\d-\d:1\.0\.0.+?\r\n'
|
P1_MESSAGE_TIMESTAMP = r'\d-\d:1\.0\.0.+?\r\n'
|
||||||
ELECTRICITY_IMPORTED_TOTAL = r'\d-\d:1\.8\.0.+?\r\n'
|
|
||||||
ELECTRICITY_USED_TARIFF_1 = r'\d-\d:1\.8\.1.+?\r\n'
|
ELECTRICITY_USED_TARIFF_1 = r'\d-\d:1\.8\.1.+?\r\n'
|
||||||
ELECTRICITY_USED_TARIFF_2 = r'\d-\d:1\.8\.2.+?\r\n'
|
ELECTRICITY_USED_TARIFF_2 = r'\d-\d:1\.8\.2.+?\r\n'
|
||||||
ELECTRICITY_EXPORTED_TOTAL = r'\d-\d:2\.8\.0.+?\r\n'
|
|
||||||
ELECTRICITY_DELIVERED_TARIFF_1 = r'\d-\d:2\.8\.1.+?\r\n'
|
ELECTRICITY_DELIVERED_TARIFF_1 = r'\d-\d:2\.8\.1.+?\r\n'
|
||||||
ELECTRICITY_DELIVERED_TARIFF_2 = r'\d-\d:2\.8\.2.+?\r\n'
|
ELECTRICITY_DELIVERED_TARIFF_2 = r'\d-\d:2\.8\.2.+?\r\n'
|
||||||
ELECTRICITY_ACTIVE_TARIFF = r'\d-\d:96\.14\.0.+?\r\n'
|
ELECTRICITY_ACTIVE_TARIFF = r'\d-\d:96\.14\.0.+?\r\n'
|
||||||
@ -62,13 +60,13 @@ ELECTRICITY_DELIVERED_TARIFF_ALL = (
|
|||||||
ELECTRICITY_DELIVERED_TARIFF_2
|
ELECTRICITY_DELIVERED_TARIFF_2
|
||||||
)
|
)
|
||||||
|
|
||||||
# Alternate codes for foreign countries.
|
# International generalized additions
|
||||||
|
ELECTRICITY_IMPORTED_TOTAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
|
||||||
|
ELECTRICITY_EXPORTED_TOTAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
|
||||||
|
|
||||||
|
# International non generalized additions (country specific) / risk for necessary refactoring
|
||||||
BELGIUM_HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.3.+?\r\n' # Different code, same format.
|
BELGIUM_HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.3.+?\r\n' # Different code, same format.
|
||||||
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'\d-\d:42\.0\.0.+?\r\n' # Logical device name
|
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'\d-\d:42\.0\.0.+?\r\n' # Logical device name
|
||||||
LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
|
|
||||||
LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
|
|
||||||
SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
|
|
||||||
SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
|
|
||||||
Q3D_EQUIPMENT_IDENTIFIER = r'\d-\d:0\.0\.0.+?\r\n' # Logical device name
|
Q3D_EQUIPMENT_IDENTIFIER = r'\d-\d:0\.0\.0.+?\r\n' # Logical device name
|
||||||
Q3D_EQUIPMENT_STATE = r'\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal)
|
Q3D_EQUIPMENT_STATE = r'\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal)
|
||||||
Q3D_EQUIPMENT_SERIALNUMBER = r'\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber
|
Q3D_EQUIPMENT_SERIALNUMBER = r'\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber
|
||||||
|
@ -153,8 +153,8 @@ BELGIUM_FLUVIUS['objects'].update({
|
|||||||
LUXEMBOURG_SMARTY = deepcopy(V5)
|
LUXEMBOURG_SMARTY = deepcopy(V5)
|
||||||
LUXEMBOURG_SMARTY['objects'].update({
|
LUXEMBOURG_SMARTY['objects'].update({
|
||||||
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||||
obis.LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
|
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
||||||
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
|
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
||||||
})
|
})
|
||||||
|
|
||||||
# Source: https://www.energiforetagen.se/globalassets/energiforetagen/det-erbjuder-vi/kurser-och-konferenser/elnat/
|
# Source: https://www.energiforetagen.se/globalassets/energiforetagen/det-erbjuder-vi/kurser-och-konferenser/elnat/
|
||||||
@ -164,8 +164,8 @@ SWEDEN = {
|
|||||||
'objects': {
|
'objects': {
|
||||||
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
||||||
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
||||||
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
|
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
||||||
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
|
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
||||||
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
||||||
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
||||||
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
||||||
|
Loading…
Reference in New Issue
Block a user