Added EON HUNGARY specification

This commit is contained in:
root 2023-07-15 23:48:43 +02:00
parent 3fd032f18f
commit 0ce469d4b8
5 changed files with 123 additions and 2 deletions

View File

@ -43,7 +43,12 @@ class SocketReader(object):
continue continue
for data in lines: for data in lines:
self.telegram_buffer.append(data.decode('ascii')) try:
self.telegram_buffer.append(data.decode('ascii'))
except UnicodeDecodeError:
# Some garbage came through the channel
# E.g.: Happens at EON_HUNGARY, but only once at the start of the socket.
pass
for telegram in self.telegram_buffer.get_all(): for telegram in self.telegram_buffer.get_all():
try: try:

View File

@ -92,7 +92,30 @@ EN = {
obis.Q3D_EQUIPMENT_IDENTIFIER: 'Q3D_EQUIPMENT_IDENTIFIER', obis.Q3D_EQUIPMENT_IDENTIFIER: 'Q3D_EQUIPMENT_IDENTIFIER',
obis.Q3D_EQUIPMENT_STATE: 'Q3D_EQUIPMENT_STATE', obis.Q3D_EQUIPMENT_STATE: 'Q3D_EQUIPMENT_STATE',
obis.Q3D_EQUIPMENT_SERIALNUMBER: 'Q3D_EQUIPMENT_SERIALNUMBER', obis.Q3D_EQUIPMENT_SERIALNUMBER: 'Q3D_EQUIPMENT_SERIALNUMBER',
obis.BELGIUM_MBUS2_DEVICE_TYPE: 'BELGIUM_MBUS2_DEVICE_TYPE' obis.BELGIUM_MBUS2_DEVICE_TYPE: 'BELGIUM_MBUS2_DEVICE_TYPE',
obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_3: 'EON_HU_ELECTRICITY_DELIVERED_TARIFF_3',
obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_4: 'EON_HU_ELECTRICITY_DELIVERED_TARIFF_4',
obis.EON_HU_ELECTRICITY_USED_TARIFF_3: 'EON_HU_ELECTRICITY_USED_TARIFF_3',
obis.EON_HU_ELECTRICITY_USED_TARIFF_4: 'EON_HU_ELECTRICITY_USED_TARIFF_4',
obis.EON_HU_CIRCUIT_BREAKER_STATUS: 'EON_HU_CIRCUIT_BREAKER_STATUS',
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q1: 'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q1',
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q2: 'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q2',
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q3: 'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q3',
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q4: 'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q4',
obis.EON_HU_ELECTRICITY_COMBINED: 'EON_HU_ELECTRICITY_COMBINED',
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_TOTAL: 'EON_HU_INSTANTANEOUS_POWER_FACTOR_TOTAL',
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L1: 'EON_HU_INSTANTANEOUS_POWER_FACTOR_L1',
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L2: 'EON_HU_INSTANTANEOUS_POWER_FACTOR_L2',
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L3: 'EON_HU_INSTANTANEOUS_POWER_FACTOR_L3',
obis.EON_HU_FREQUENCY: 'EON_HU_FREQUENCY',
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q1: 'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q1',
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q2: 'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q2',
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3: 'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3',
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4: 'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4',
obis.EON_HU_MAX_POWER_ON_L1: 'EON_HU_MAX_POWER_ON_L1',
obis.EON_HU_MAX_POWER_ON_L2: 'EON_HU_MAX_POWER_ON_L2',
obis.EON_HU_MAX_POWER_ON_L3: 'EON_HU_MAX_POWER_ON_L3',
obis.EON_HU_LAST_MONTH_DATA: 'EON_HU_LAST_MONTH_DATA'
} }
REVERSE_EN = dict([(v, k) for k, v in EN.items()]) REVERSE_EN = dict([(v, k) for k, v in EN.items()])

View File

@ -122,3 +122,28 @@ LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'^\d-\d:42\.0\.0.+?\r\n' # Logical device na
Q3D_EQUIPMENT_IDENTIFIER = r'^\d-\d:0\.0\.0.+?\r\n' # Logical device name Q3D_EQUIPMENT_IDENTIFIER = r'^\d-\d:0\.0\.0.+?\r\n' # Logical device name
Q3D_EQUIPMENT_STATE = r'^\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal) Q3D_EQUIPMENT_STATE = r'^\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal)
Q3D_EQUIPMENT_SERIALNUMBER = r'^\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber Q3D_EQUIPMENT_SERIALNUMBER = r'^\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber
# EON Hungary
EON_HU_ELECTRICITY_USED_TARIFF_3 = r'^\d-\d:1\.8\.3.+?\r\n'
EON_HU_ELECTRICITY_USED_TARIFF_4 = r'^\d-\d:1\.8\.4.+?\r\n'
EON_HU_ELECTRICITY_DELIVERED_TARIFF_3 = r'^\d-\d:2\.8\.3.+?\r\n'
EON_HU_ELECTRICITY_DELIVERED_TARIFF_4 = r'^\d-\d:2\.8\.4.+?\r\n'
EON_HU_CIRCUIT_BREAKER_STATUS = r'^\d-\d:96\.50\.68.+?\r\n'
EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q1 = r'^\d-\d:5\.8\.0.+?\r\n'
EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q2 = r'^\d-\d:6\.8\.0.+?\r\n'
EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q3 = r'^\d-\d:7\.8\.0.+?\r\n'
EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q4 = r'^\d-\d:8\.8\.0.+?\r\n'
EON_HU_ELECTRICITY_COMBINED = r'^\d-\d:15\.8\.0.+?\r\n'
EON_HU_INSTANTANEOUS_POWER_FACTOR_TOTAL = r'^\d-\d:13\.7\.0.+?\r\n'
EON_HU_INSTANTANEOUS_POWER_FACTOR_L1 = r'^\d-\d:33\.7\.0.+?\r\n'
EON_HU_INSTANTANEOUS_POWER_FACTOR_L2 = r'^\d-\d:53\.7\.0.+?\r\n'
EON_HU_INSTANTANEOUS_POWER_FACTOR_L3 = r'^\d-\d:73\.7\.0.+?\r\n'
EON_HU_FREQUENCY = r'^\d-\d:14\.7\.0.+?\r\n'
EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q1 = r'^\d-\d:5\.7\.0.+?\r\n'
EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q2 = r'^\d-\d:6\.7\.0.+?\r\n'
EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3 = r'^\d-\d:7\.7\.0.+?\r\n'
EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4 = r'^\d-\d:8\.7\.0.+?\r\n'
EON_HU_MAX_POWER_ON_L1 = r'^\d-\d:31\.4\.0.+?\r\n'
EON_HU_MAX_POWER_ON_L2 = r'^\d-\d:51\.4\.0.+?\r\n'
EON_HU_MAX_POWER_ON_L3 = r'^\d-\d:71\.4\.0.+?\r\n'
EON_HU_LAST_MONTH_DATA = r'^\d-\d:98\.1\.0.+?\r\n'

View File

@ -339,3 +339,59 @@ ISKRA_IE = {
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)), obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
} }
} }
HUNGARY_EON = {
# Revision: 2023.02.10
# Based on V5
'checksum_support': True,
'objects': {
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)), # "COSEM logical equipment name"
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)), # This obis is already defined, so it is not possible to "rename" it to "EQUIPMENT_SERIAL_NUMBER"
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
obis.EON_HU_CIRCUIT_BREAKER_STATUS: CosemParser(ValueParser(str)), # Does not show up always
obis.ACTUAL_TRESHOLD_ELECTRICITY: CosemParser(ValueParser(Decimal)), # This obis is already duplicated, so it will show up as "BELGIUM_MAX_POWER_PER_PHASE"
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_USED_TARIFF_3: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_USED_TARIFF_4: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_3: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_4: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_REACTIVE_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_REACTIVE_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q1: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q2: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q3: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q4: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_COMBINED: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_TOTAL: CosemParser(ValueParser(Decimal)),
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L1: CosemParser(ValueParser(Decimal)),
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.EON_HU_FREQUENCY: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q1: CosemParser(ValueParser(Decimal)),
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3: CosemParser(ValueParser(Decimal)),
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3: CosemParser(ValueParser(Decimal)),
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4: CosemParser(ValueParser(Decimal)),
obis.EON_HU_MAX_POWER_ON_L1: CosemParser(ValueParser(Decimal)),
obis.EON_HU_MAX_POWER_ON_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.EON_HU_MAX_POWER_ON_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
# This is a list of last month data (on last day of last month @ 23:59:59),
# But it is not clear that what are the elements of the list.
# This is not well documented enough, so It is ignored for now.
# obis.EON_HU_LAST_MONTH_DATA:
obis.TEXT_MESSAGE: CosemParser(ValueParser(str))
}
}

12
test.tox Normal file
View File

@ -0,0 +1,12 @@
from dsmr_parser import telegram_specifications
from dsmr_parser.clients import SocketReader
socket_reader = SocketReader(
host='10.0.1.100',
port=23,
telegram_specification=telegram_specifications.HUNGARY_EON
)
for telegram in socket_reader.read():
print(telegram) # see 'Telegram object' docs below