from decimal import Decimal
|
|
from copy import deepcopy
|
|
|
|
from dsmr_parser import obis_references as obis
|
|
from dsmr_parser.parsers import CosemParser, ValueParser, MBusParser, ProfileGenericParser, MaxDemandParser
|
|
from dsmr_parser.value_types import timestamp
|
|
from dsmr_parser.profile_generic_specifications import BUFFER_TYPES, PG_HEAD_PARSERS, PG_UNIDENTIFIED_BUFFERTYPE_PARSERS
|
|
|
|
"""
|
|
dsmr_parser.telegram_specifications
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
This module contains DSMR telegram specifications. Each specifications describes
|
|
how the telegram lines are parsed.
|
|
"""
|
|
|
|
V2_2 = {
|
|
'checksum_support': False,
|
|
'objects': {
|
|
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
|
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
|
|
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
|
obis.ACTUAL_TRESHOLD_ELECTRICITY: CosemParser(ValueParser(Decimal)),
|
|
obis.ACTUAL_SWITCH_POSITION: CosemParser(ValueParser(str)),
|
|
obis.TEXT_MESSAGE_CODE: CosemParser(ValueParser(int)),
|
|
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
|
|
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
|
|
obis.DEVICE_TYPE: CosemParser(ValueParser(str)),
|
|
obis.VALVE_POSITION_GAS: CosemParser(ValueParser(str)),
|
|
obis.GAS_METER_READING: MBusParser(
|
|
ValueParser(timestamp),
|
|
ValueParser(str), # changed to str see issue60
|
|
ValueParser(int),
|
|
ValueParser(int),
|
|
ValueParser(str), # obis ref
|
|
ValueParser(str), # unit, position 5
|
|
ValueParser(Decimal), # meter reading, position 6
|
|
),
|
|
}
|
|
}
|
|
|
|
V3 = V2_2
|
|
|
|
V4 = {
|
|
'checksum_support': True,
|
|
'objects': {
|
|
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
|
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
|
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
|
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
|
|
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
|
obis.SHORT_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
|
|
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
|
|
obis.POWER_EVENT_FAILURE_LOG:
|
|
ProfileGenericParser(BUFFER_TYPES,
|
|
PG_HEAD_PARSERS,
|
|
PG_UNIDENTIFIED_BUFFERTYPE_PARSERS),
|
|
obis.VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
|
|
obis.VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
|
|
obis.VOLTAGE_SAG_L3_COUNT: CosemParser(ValueParser(int)),
|
|
obis.VOLTAGE_SWELL_L1_COUNT: CosemParser(ValueParser(int)),
|
|
obis.VOLTAGE_SWELL_L2_COUNT: CosemParser(ValueParser(int)),
|
|
obis.VOLTAGE_SWELL_L3_COUNT: CosemParser(ValueParser(int)),
|
|
obis.TEXT_MESSAGE_CODE: CosemParser(ValueParser(int)),
|
|
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
|
|
obis.DEVICE_TYPE: CosemParser(ValueParser(int)),
|
|
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
|
|
obis.HOURLY_GAS_METER_READING: MBusParser(
|
|
ValueParser(timestamp),
|
|
ValueParser(Decimal)
|
|
)
|
|
}
|
|
}
|
|
|
|
V5 = {
|
|
'checksum_support': True,
|
|
'objects': {
|
|
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
|
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
|
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
|
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
|
|
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
|
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
|
|
obis.SHORT_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
|
|
obis.POWER_EVENT_FAILURE_LOG:
|
|
ProfileGenericParser(BUFFER_TYPES,
|
|
PG_HEAD_PARSERS,
|
|
PG_UNIDENTIFIED_BUFFERTYPE_PARSERS),
|
|
obis.VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
|
|
obis.VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
|
|
obis.VOLTAGE_SAG_L3_COUNT: CosemParser(ValueParser(int)),
|
|
obis.VOLTAGE_SWELL_L1_COUNT: CosemParser(ValueParser(int)),
|
|
obis.VOLTAGE_SWELL_L2_COUNT: CosemParser(ValueParser(int)),
|
|
obis.VOLTAGE_SWELL_L3_COUNT: CosemParser(ValueParser(int)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
|
|
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
|
|
obis.DEVICE_TYPE: CosemParser(ValueParser(int)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
|
|
obis.HOURLY_GAS_METER_READING: MBusParser(
|
|
ValueParser(timestamp),
|
|
ValueParser(Decimal)
|
|
)
|
|
}
|
|
}
|
|
|
|
ALL = (V2_2, V3, V4, V5)
|
|
|
|
BELGIUM_FLUVIUS = {
|
|
'checksum_support': True,
|
|
'objects': {
|
|
obis.BELGIUM_VERSION_INFORMATION: CosemParser(ValueParser(str)),
|
|
obis.BELGIUM_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
|
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
|
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
|
|
obis.BELGIUM_CURRENT_AVERAGE_DEMAND: CosemParser(ValueParser(Decimal)),
|
|
obis.BELGIUM_MAXIMUM_DEMAND_MONTH: MBusParser(
|
|
ValueParser(timestamp),
|
|
ValueParser(Decimal)
|
|
),
|
|
obis.BELGIUM_MAXIMUM_DEMAND_13_MONTHS: MaxDemandParser(),
|
|
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
|
|
obis.ACTUAL_SWITCH_POSITION: CosemParser(ValueParser(int)),
|
|
obis.ACTUAL_TRESHOLD_ELECTRICITY: CosemParser(ValueParser(Decimal)),
|
|
obis.BELGIUM_MAX_POWER_PER_PHASE: CosemParser(ValueParser(Decimal)),
|
|
obis.BELGIUM_MAX_CURRENT_PER_PHASE: CosemParser(ValueParser(Decimal)),
|
|
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
|
|
obis.BELGIUM_MBUS1_DEVICE_TYPE: CosemParser(ValueParser(int)),
|
|
obis.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
|
obis.BELGIUM_MBUS1_VALVE_POSITION: CosemParser(ValueParser(int)),
|
|
obis.BELGIUM_MBUS1_METER_READING1: MBusParser(
|
|
ValueParser(timestamp),
|
|
ValueParser(Decimal)
|
|
),
|
|
obis.BELGIUM_MBUS1_METER_READING2: MBusParser(
|
|
ValueParser(timestamp),
|
|
ValueParser(Decimal)
|
|
),
|
|
obis.BELGIUM_MBUS2_DEVICE_TYPE: CosemParser(ValueParser(int)),
|
|
obis.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
|
obis.BELGIUM_MBUS2_VALVE_POSITION: CosemParser(ValueParser(int)),
|
|
obis.BELGIUM_MBUS2_METER_READING1: MBusParser(
|
|
ValueParser(timestamp),
|
|
ValueParser(Decimal)
|
|
),
|
|
obis.BELGIUM_MBUS2_METER_READING2: MBusParser(
|
|
ValueParser(timestamp),
|
|
ValueParser(Decimal)
|
|
),
|
|
obis.BELGIUM_MBUS3_DEVICE_TYPE: CosemParser(ValueParser(int)),
|
|
obis.BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
|
obis.BELGIUM_MBUS3_VALVE_POSITION: CosemParser(ValueParser(int)),
|
|
obis.BELGIUM_MBUS3_METER_READING1: MBusParser(
|
|
ValueParser(timestamp),
|
|
ValueParser(Decimal)
|
|
),
|
|
obis.BELGIUM_MBUS3_METER_READING2: MBusParser(
|
|
ValueParser(timestamp),
|
|
ValueParser(Decimal)
|
|
),
|
|
obis.BELGIUM_MBUS4_DEVICE_TYPE: CosemParser(ValueParser(int)),
|
|
obis.BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
|
obis.BELGIUM_MBUS4_VALVE_POSITION: CosemParser(ValueParser(int)),
|
|
obis.BELGIUM_MBUS4_METER_READING1: MBusParser(
|
|
ValueParser(timestamp),
|
|
ValueParser(Decimal)
|
|
),
|
|
obis.BELGIUM_MBUS4_METER_READING2: MBusParser(
|
|
ValueParser(timestamp),
|
|
ValueParser(Decimal)
|
|
),
|
|
}
|
|
}
|
|
|
|
LUXEMBOURG_SMARTY = deepcopy(V5)
|
|
LUXEMBOURG_SMARTY['objects'].update({
|
|
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
|
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
})
|
|
|
|
# Source: https://www.energiforetagen.se/globalassets/energiforetagen/det-erbjuder-vi/kurser-och-konferenser/elnat/
|
|
# branschrekommendation-lokalt-granssnitt-v2_0-201912.pdf
|
|
SWEDEN = {
|
|
'checksum_support': True,
|
|
'objects': {
|
|
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
|
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
|
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_REACTIVE_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_REACTIVE_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_REACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_REACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_REACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_REACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_REACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_REACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
|
|
}
|
|
}
|
|
|
|
Q3D = {
|
|
"checksum_support": False,
|
|
"objects": {
|
|
obis.Q3D_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
|
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
|
obis.Q3D_EQUIPMENT_STATE: CosemParser(ValueParser(str)),
|
|
obis.Q3D_EQUIPMENT_SERIALNUMBER: CosemParser(ValueParser(str)),
|
|
},
|
|
}
|
|
|
|
|
|
SAGEMCOM_T210_D_R = {
|
|
"general_global_cipher": True,
|
|
"checksum_support": True,
|
|
'objects': {
|
|
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
|
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
|
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
|
|
|
obis.ELECTRICITY_REACTIVE_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_REACTIVE_IMPORTED: CosemParser(ValueParser(Decimal)),
|
|
|
|
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
|
|
|
obis.ELECTRICITY_REACTIVE_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_REACTIVE_EXPORTED: CosemParser(ValueParser(Decimal)),
|
|
}
|
|
}
|
|
AUSTRIA_ENERGIENETZE_STEIERMARK = SAGEMCOM_T210_D_R
|
|
|
|
ISKRA_IE = {
|
|
"checksum_support": False,
|
|
'objects': {
|
|
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
|
|
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
|
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
|
|
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
|
|
obis.ACTUAL_SWITCH_POSITION: CosemParser(ValueParser(str)),
|
|
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
|
|
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
|
}
|
|
}
|
|
|
|
HUNGARY_EON = {
|
|
# Revision: 2023.02.10
|
|
# Based on V5
|
|
'checksum_support': True,
|
|
'objects': {
|
|
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
|
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)), # "COSEM logical equipment name"
|
|
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)), # This obis is already defined, so it is not possible to "rename" it to "EQUIPMENT_SERIAL_NUMBER"
|
|
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
|
|
obis.EON_HU_CIRCUIT_BREAKER_STATUS: CosemParser(ValueParser(str)), # Does not show up always
|
|
obis.ACTUAL_TRESHOLD_ELECTRICITY: CosemParser(ValueParser(Decimal)), # This obis is already duplicated, so it will show up as "BELGIUM_MAX_POWER_PER_PHASE"
|
|
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_ELECTRICITY_USED_TARIFF_3: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_ELECTRICITY_USED_TARIFF_4: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_3: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_4: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_REACTIVE_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.ELECTRICITY_REACTIVE_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q1: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q2: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q3: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q4: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_ELECTRICITY_COMBINED: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
|
|
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
|
|
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
|
|
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
|
|
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_TOTAL: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
|
|
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
|
|
obis.EON_HU_FREQUENCY: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
|
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q1: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_MAX_POWER_ON_L1: CosemParser(ValueParser(Decimal)),
|
|
obis.EON_HU_MAX_POWER_ON_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
|
|
obis.EON_HU_MAX_POWER_ON_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
|
|
# This is a list of last month data (on last day of last month @ 23:59:59),
|
|
# But it is not clear that what are the elements of the list.
|
|
# This is not well documented enough, so It is ignored for now.
|
|
# obis.EON_HU_LAST_MONTH_DATA:
|
|
obis.TEXT_MESSAGE: CosemParser(ValueParser(str))
|
|
}
|
|
}
|