from decimal import Decimal
from copy import deepcopy
from dsmr_parser import obis_references as obis
from dsmr_parser.parsers import CosemParser, ValueParser, MBusParser, ProfileGenericParser, MaxDemandParser
from dsmr_parser.value_types import timestamp
from dsmr_parser.profile_generic_specifications import BUFFER_TYPES, PG_HEAD_PARSERS, PG_UNIDENTIFIED_BUFFERTYPE_PARSERS
"""
dsmr_parser.telegram_specifications
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
This module contains DSMR telegram specifications. Each specifications describes
how the telegram lines are parsed.
"""
V2_2 = {
'checksum_support': False,
'objects': {
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.ACTUAL_TRESHOLD_ELECTRICITY: CosemParser(ValueParser(Decimal)),
obis.ACTUAL_SWITCH_POSITION: CosemParser(ValueParser(str)),
obis.TEXT_MESSAGE_CODE: CosemParser(ValueParser(int)),
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
obis.DEVICE_TYPE: CosemParser(ValueParser(str)),
obis.VALVE_POSITION_GAS: CosemParser(ValueParser(str)),
obis.GAS_METER_READING: MBusParser(
ValueParser(timestamp),
ValueParser(str), # changed to str see issue60
ValueParser(int),
ValueParser(int),
ValueParser(str), # obis ref
ValueParser(str), # unit, position 5
ValueParser(Decimal), # meter reading, position 6
),
}
}
V3 = V2_2
V4 = {
'checksum_support': True,
'objects': {
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.SHORT_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
obis.POWER_EVENT_FAILURE_LOG:
ProfileGenericParser(BUFFER_TYPES,
PG_HEAD_PARSERS,
PG_UNIDENTIFIED_BUFFERTYPE_PARSERS),
obis.VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SAG_L3_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SWELL_L1_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SWELL_L2_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SWELL_L3_COUNT: CosemParser(ValueParser(int)),
obis.TEXT_MESSAGE_CODE: CosemParser(ValueParser(int)),
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
obis.DEVICE_TYPE: CosemParser(ValueParser(int)),
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
obis.HOURLY_GAS_METER_READING: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
)
}
}
V5 = {
'checksum_support': True,
'objects': {
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
obis.SHORT_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
obis.POWER_EVENT_FAILURE_LOG:
ProfileGenericParser(BUFFER_TYPES,
PG_HEAD_PARSERS,
PG_UNIDENTIFIED_BUFFERTYPE_PARSERS),
obis.VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SAG_L3_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SWELL_L1_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SWELL_L2_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SWELL_L3_COUNT: CosemParser(ValueParser(int)),
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
obis.DEVICE_TYPE: CosemParser(ValueParser(int)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
obis.HOURLY_GAS_METER_READING: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
)
}
}
ALL = (V2_2, V3, V4, V5)
BELGIUM_FLUVIUS = {
'checksum_support': True,
'objects': {
obis.BELGIUM_VERSION_INFORMATION: CosemParser(ValueParser(str)),
obis.BELGIUM_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
obis.BELGIUM_CURRENT_AVERAGE_DEMAND: CosemParser(ValueParser(Decimal)),
obis.BELGIUM_MAXIMUM_DEMAND_MONTH: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
obis.BELGIUM_MAXIMUM_DEMAND_13_MONTHS: MaxDemandParser(),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
obis.ACTUAL_SWITCH_POSITION: CosemParser(ValueParser(int)),
obis.ACTUAL_TRESHOLD_ELECTRICITY: CosemParser(ValueParser(Decimal)),
obis.BELGIUM_MAX_POWER_PER_PHASE: CosemParser(ValueParser(Decimal)),
obis.BELGIUM_MAX_CURRENT_PER_PHASE: CosemParser(ValueParser(Decimal)),
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
obis.BELGIUM_MBUS1_DEVICE_TYPE: CosemParser(ValueParser(int)),
obis.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.BELGIUM_MBUS1_VALVE_POSITION: CosemParser(ValueParser(int)),
obis.BELGIUM_MBUS1_METER_READING1: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
obis.BELGIUM_MBUS1_METER_READING2: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
obis.BELGIUM_MBUS2_DEVICE_TYPE: CosemParser(ValueParser(int)),
obis.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.BELGIUM_MBUS2_VALVE_POSITION: CosemParser(ValueParser(int)),
obis.BELGIUM_MBUS2_METER_READING1: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
obis.BELGIUM_MBUS2_METER_READING2: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
obis.BELGIUM_MBUS3_DEVICE_TYPE: CosemParser(ValueParser(int)),
obis.BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.BELGIUM_MBUS3_VALVE_POSITION: CosemParser(ValueParser(int)),
obis.BELGIUM_MBUS3_METER_READING1: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
obis.BELGIUM_MBUS3_METER_READING2: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
obis.BELGIUM_MBUS4_DEVICE_TYPE: CosemParser(ValueParser(int)),
obis.BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.BELGIUM_MBUS4_VALVE_POSITION: CosemParser(ValueParser(int)),
obis.BELGIUM_MBUS4_METER_READING1: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
obis.BELGIUM_MBUS4_METER_READING2: MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
}
}
LUXEMBOURG_SMARTY = deepcopy(V5)
LUXEMBOURG_SMARTY['objects'].update({
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
})
# Source: https://www.energiforetagen.se/globalassets/energiforetagen/det-erbjuder-vi/kurser-och-konferenser/elnat/
# branschrekommendation-lokalt-granssnitt-v2_0-201912.pdf
SWEDEN = {
'checksum_support': True,
'objects': {
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_REACTIVE_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_REACTIVE_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_REACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_REACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_REACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_REACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_REACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_REACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
}
}
Q3D = {
"checksum_support": False,
"objects": {
obis.Q3D_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.Q3D_EQUIPMENT_STATE: CosemParser(ValueParser(str)),
obis.Q3D_EQUIPMENT_SERIALNUMBER: CosemParser(ValueParser(str)),
},
}
SAGEMCOM_T210_D_R = {
"general_global_cipher": True,
"checksum_support": True,
'objects': {
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_REACTIVE_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.CURRENT_REACTIVE_IMPORTED: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_REACTIVE_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.CURRENT_REACTIVE_EXPORTED: CosemParser(ValueParser(Decimal)),
}
}
AUSTRIA_ENERGIENETZE_STEIERMARK = SAGEMCOM_T210_D_R
ISKRA_IE = {
"checksum_support": False,
'objects': {
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
obis.ACTUAL_SWITCH_POSITION: CosemParser(ValueParser(str)),
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
}
}
HUNGARY_EON = {
# Revision: 2023.02.10
# Based on V5
'checksum_support': True,
'objects': {
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)), # "COSEM logical equipment name"
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)), # This obis is already defined, so it is not possible to "rename" it to "EQUIPMENT_SERIAL_NUMBER"
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
obis.EON_HU_CIRCUIT_BREAKER_STATUS: CosemParser(ValueParser(str)), # Does not show up always
obis.ACTUAL_TRESHOLD_ELECTRICITY: CosemParser(ValueParser(Decimal)), # This obis is already duplicated, so it will show up as "BELGIUM_MAX_POWER_PER_PHASE"
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_USED_TARIFF_3: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_USED_TARIFF_4: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_3: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_4: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_REACTIVE_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_REACTIVE_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q1: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q2: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q3: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q4: CosemParser(ValueParser(Decimal)),
obis.EON_HU_ELECTRICITY_COMBINED: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_TOTAL: CosemParser(ValueParser(Decimal)),
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L1: CosemParser(ValueParser(Decimal)),
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.EON_HU_FREQUENCY: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q1: CosemParser(ValueParser(Decimal)),
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3: CosemParser(ValueParser(Decimal)),
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3: CosemParser(ValueParser(Decimal)),
obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4: CosemParser(ValueParser(Decimal)),
obis.EON_HU_MAX_POWER_ON_L1: CosemParser(ValueParser(Decimal)),
obis.EON_HU_MAX_POWER_ON_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
obis.EON_HU_MAX_POWER_ON_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
# This is a list of last month data (on last day of last month @ 23:59:59),
# But it is not clear that what are the elements of the list.
# This is not well documented enough, so It is ignored for now.
# obis.EON_HU_LAST_MONTH_DATA:
obis.TEXT_MESSAGE: CosemParser(ValueParser(str))
}
}