Merge pull request #92 from Aeroid/master

Support for (German) EasyMeter Q3D using COM-1 Ethernet Gateway
This commit is contained in:
2021-11-21 13:59:35 +01:00
committed by GitHub
6 changed files with 73 additions and 3 deletions
+2 -2
View File
@@ -16,8 +16,8 @@ def console():
help='alternatively connect using TCP host.')
parser.add_argument('--port', default=None,
help='TCP port to use for connection')
parser.add_argument('--version', default='2.2', choices=['2.2', '4', '5', '5B', '5L', '5S'],
help='DSMR version (2.2, 4, 5, 5B, 5L, 5S)')
parser.add_argument('--version', default='2.2', choices=['2.2', '4', '5', '5B', '5L', '5S', 'Q3D'],
help='DSMR version (2.2, 4, 5, 5B, 5L, 5S, Q3D)')
parser.add_argument('--verbose', '-v', action='count')
args = parser.parse_args()
+8 -1
View File
@@ -38,6 +38,9 @@ def create_dsmr_protocol(dsmr_version, telegram_callback, loop=None, **kwargs):
elif dsmr_version == "5S":
specification = telegram_specifications.SWEDEN
serial_settings = SERIAL_SETTINGS_V5
elif dsmr_version == "Q3D":
specification = telegram_specifications.Q3D
serial_settings = SERIAL_SETTINGS_V5
else:
raise NotImplementedError("No telegram parser found for version: %s",
dsmr_version)
@@ -102,12 +105,16 @@ class DSMRProtocol(asyncio.Protocol):
def data_received(self, data):
"""Add incoming data to buffer."""
data = data.decode('ascii')
# accept latin-1 (8-bit) on the line, to allow for non-ascii transport or padding
data = data.decode("latin1")
self._active = True
self.log.debug('received data: %s', data)
self.telegram_buffer.append(data)
for telegram in self.telegram_buffer.get_all():
# ensure actual telegram is ascii (7-bit) only (IEC 646 required in section 5.4 of IEC 62056-21)
telegram = telegram.encode("latin1").decode("ascii")
self.handle_telegram(telegram)
def keep_alive(self):
+4
View File
@@ -13,6 +13,7 @@ EN = {
obis.ELECTRICITY_IMPORTED_TOTAL: 'ELECTRICITY_IMPORTED_TOTAL',
obis.ELECTRICITY_USED_TARIFF_1: 'ELECTRICITY_USED_TARIFF_1',
obis.ELECTRICITY_USED_TARIFF_2: 'ELECTRICITY_USED_TARIFF_2',
obis.ELECTRICITY_EXPORTED_TOTAL: 'ELECTRICITY_EXPORTED_TOTAL',
obis.ELECTRICITY_DELIVERED_TARIFF_1: 'ELECTRICITY_DELIVERED_TARIFF_1',
obis.ELECTRICITY_DELIVERED_TARIFF_2: 'ELECTRICITY_DELIVERED_TARIFF_2',
obis.ELECTRICITY_ACTIVE_TARIFF: 'ELECTRICITY_ACTIVE_TARIFF',
@@ -55,6 +56,9 @@ EN = {
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL',
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
obis.Q3D_EQUIPMENT_IDENTIFIER: 'Q3D_EQUIPMENT_IDENTIFIER',
obis.Q3D_EQUIPMENT_STATE: 'Q3D_EQUIPMENT_STATE',
obis.Q3D_EQUIPMENT_SERIALNUMBER: 'Q3D_EQUIPMENT_SERIALNUMBER',
}
REVERSE_EN = dict([(v, k) for k, v in EN.items()])
+4
View File
@@ -11,6 +11,7 @@ P1_MESSAGE_TIMESTAMP = r'\d-\d:1\.0\.0.+?\r\n'
ELECTRICITY_IMPORTED_TOTAL = r'\d-\d:1\.8\.0.+?\r\n'
ELECTRICITY_USED_TARIFF_1 = r'\d-\d:1\.8\.1.+?\r\n'
ELECTRICITY_USED_TARIFF_2 = r'\d-\d:1\.8\.2.+?\r\n'
ELECTRICITY_EXPORTED_TOTAL = r'\d-\d:2\.8\.0.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_1 = r'\d-\d:2\.8\.1.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_2 = r'\d-\d:2\.8\.2.+?\r\n'
ELECTRICITY_ACTIVE_TARIFF = r'\d-\d:96\.14\.0.+?\r\n'
@@ -68,3 +69,6 @@ LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imp
LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
Q3D_EQUIPMENT_IDENTIFIER = r'\d-\d:0\.0\.0.+?\r\n' # Logical device name
Q3D_EQUIPMENT_STATE = r'\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal)
Q3D_EQUIPMENT_SERIALNUMBER = r'\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber
+15
View File
@@ -182,3 +182,18 @@ SWEDEN = {
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
}
}
Q3D = {
"checksum_support": False,
"objects": {
obis.Q3D_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.Q3D_EQUIPMENT_STATE: CosemParser(ValueParser(str)),
obis.Q3D_EQUIPMENT_SERIALNUMBER: CosemParser(ValueParser(str)),
},
}