Contains the signatures of each telegram line.
|
|
|
|
Previously contained the channel + obis reference signatures, but has been
|
|
refactored to full line signatures to maintain backwards compatibility.
|
|
Might be refactored in a backwards incompatible way as soon as proper telegram
|
|
objects are introduced.
|
|
"""
|
|
P1_MESSAGE_HEADER = r'\d-\d:0\.2\.8.+?\r\n'
|
|
P1_MESSAGE_TIMESTAMP = r'\d-\d:1\.0\.0.+?\r\n'
|
|
ELECTRICITY_IMPORTED_TOTAL = r'\d-\d:1\.8\.0.+?\r\n'
|
|
ELECTRICITY_USED_TARIFF_1 = r'\d-\d:1\.8\.1.+?\r\n'
|
|
ELECTRICITY_USED_TARIFF_2 = r'\d-\d:1\.8\.2.+?\r\n'
|
|
ELECTRICITY_DELIVERED_TARIFF_1 = r'\d-\d:2\.8\.1.+?\r\n'
|
|
ELECTRICITY_DELIVERED_TARIFF_2 = r'\d-\d:2\.8\.2.+?\r\n'
|
|
ELECTRICITY_ACTIVE_TARIFF = r'\d-\d:96\.14\.0.+?\r\n'
|
|
EQUIPMENT_IDENTIFIER = r'\d-\d:96\.1\.1.+?\r\n'
|
|
CURRENT_ELECTRICITY_USAGE = r'\d-\d:1\.7\.0.+?\r\n'
|
|
CURRENT_ELECTRICITY_DELIVERY = r'\d-\d:2\.7\.0.+?\r\n'
|
|
LONG_POWER_FAILURE_COUNT = r'96\.7\.9.+?\r\n'
|
|
SHORT_POWER_FAILURE_COUNT = r'96\.7\.21.+?\r\n'
|
|
POWER_EVENT_FAILURE_LOG = r'99\.97\.0.+?\r\n'
|
|
VOLTAGE_SAG_L1_COUNT = r'\d-\d:32\.32\.0.+?\r\n'
|
|
VOLTAGE_SAG_L2_COUNT = r'\d-\d:52\.32\.0.+?\r\n'
|
|
VOLTAGE_SAG_L3_COUNT = r'\d-\d:72\.32\.0.+?\r\n'
|
|
VOLTAGE_SWELL_L1_COUNT = r'\d-\d:32\.36\.0.+?\r\n'
|
|
VOLTAGE_SWELL_L2_COUNT = r'\d-\d:52\.36\.0.+?\r\n'
|
|
VOLTAGE_SWELL_L3_COUNT = r'\d-\d:72\.36\.0.+?\r\n'
|
|
INSTANTANEOUS_VOLTAGE_L1 = r'\d-\d:32\.7\.0.+?\r\n'
|
|
INSTANTANEOUS_VOLTAGE_L2 = r'\d-\d:52\.7\.0.+?\r\n'
|
|
INSTANTANEOUS_VOLTAGE_L3 = r'\d-\d:72\.7\.0.+?\r\n'
|
|
INSTANTANEOUS_CURRENT_L1 = r'\d-\d:31\.7\.0.+?\r\n'
|
|
INSTANTANEOUS_CURRENT_L2 = r'\d-\d:51\.7\.0.+?\r\n'
|
|
INSTANTANEOUS_CURRENT_L3 = r'\d-\d:71\.7\.0.+?\r\n'
|
|
TEXT_MESSAGE_CODE = r'\d-\d:96\.13\.1.+?\r\n'
|
|
TEXT_MESSAGE = r'\d-\d:96\.13\.0.+?\r\n'
|
|
DEVICE_TYPE = r'\d-\d:24\.1\.0.+?\r\n'
|
|
INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE = r'\d-\d:21\.7\.0.+?\r\n'
|
|
INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE = r'\d-\d:41\.7\.0.+?\r\n'
|
|
INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE = r'\d-\d:61\.7\.0.+?\r\n'
|
|
INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r'\d-\d:22\.7\.0.+?\r\n'
|
|
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r'\d-\d:42\.7\.0.+?\r\n'
|
|
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r'\d-\d:62\.7\.0.+?\r\n'
|
|
EQUIPMENT_IDENTIFIER_GAS = r'\d-\d:96\.1\.0.+?\r\n'
|
|
# TODO differences between gas meter readings in v3 and lower and v4 and up
|
|
HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.1.+?\r\n'
|
|
GAS_METER_READING = r'\d-\d:24\.3\.0.+?\r\n.+?\r\n'
|
|
ACTUAL_TRESHOLD_ELECTRICITY = r'\d-\d:17\.0\.0.+?\r\n'
|
|
ACTUAL_SWITCH_POSITION = r'\d-\d:96\.3\.10.+?\r\n'
|
|
VALVE_POSITION_GAS = r'\d-\d:24\.4\.0.+?\r\n'
|
|
|
|
# TODO 17.0.0
|
|
# TODO 96.3.10
|
|
|
|
ELECTRICITY_USED_TARIFF_ALL = (
|
|
ELECTRICITY_USED_TARIFF_1,
|
|
ELECTRICITY_USED_TARIFF_2
|
|
)
|
|
ELECTRICITY_DELIVERED_TARIFF_ALL = (
|
|
ELECTRICITY_DELIVERED_TARIFF_1,
|
|
ELECTRICITY_DELIVERED_TARIFF_2
|
|
)
|
|
|
|
# Alternate codes for foreign countries.
|
|
BELGIUM_HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.3.+?\r\n' # Different code, same format.
|
|
LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
|
|
LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
|