decode latin1 and added ELECTRICITY_EXPORTED_TOTAL
This commit is contained in:
parent
4073917d3e
commit
df59f3a498
@ -10,26 +10,23 @@ from dsmr_parser import telegram_specifications
|
||||
from dsmr_parser.clients.telegram_buffer import TelegramBuffer
|
||||
from dsmr_parser.exceptions import ParseError, InvalidChecksumError
|
||||
from dsmr_parser.parsers import TelegramParser
|
||||
from dsmr_parser.clients.settings import (
|
||||
SERIAL_SETTINGS_V2_2,
|
||||
SERIAL_SETTINGS_V4,
|
||||
SERIAL_SETTINGS_V5,
|
||||
)
|
||||
from dsmr_parser.clients.settings import SERIAL_SETTINGS_V2_2, \
|
||||
SERIAL_SETTINGS_V4, SERIAL_SETTINGS_V5
|
||||
|
||||
|
||||
def create_dsmr_protocol(dsmr_version, telegram_callback, loop=None, **kwargs):
|
||||
"""Creates a DSMR asyncio protocol."""
|
||||
|
||||
if dsmr_version == "2.2":
|
||||
if dsmr_version == '2.2':
|
||||
specification = telegram_specifications.V2_2
|
||||
serial_settings = SERIAL_SETTINGS_V2_2
|
||||
elif dsmr_version == "4":
|
||||
elif dsmr_version == '4':
|
||||
specification = telegram_specifications.V4
|
||||
serial_settings = SERIAL_SETTINGS_V4
|
||||
elif dsmr_version == "5":
|
||||
elif dsmr_version == '5':
|
||||
specification = telegram_specifications.V5
|
||||
serial_settings = SERIAL_SETTINGS_V5
|
||||
elif dsmr_version == "5B":
|
||||
elif dsmr_version == '5B':
|
||||
specification = telegram_specifications.BELGIUM_FLUVIUS
|
||||
serial_settings = SERIAL_SETTINGS_V5
|
||||
elif dsmr_version == "5L":
|
||||
@ -42,17 +39,11 @@ def create_dsmr_protocol(dsmr_version, telegram_callback, loop=None, **kwargs):
|
||||
specification = telegram_specifications.Q3D
|
||||
serial_settings = SERIAL_SETTINGS_V5
|
||||
else:
|
||||
raise NotImplementedError(
|
||||
"No telegram parser found for version: %s", dsmr_version
|
||||
)
|
||||
raise NotImplementedError("No telegram parser found for version: %s",
|
||||
dsmr_version)
|
||||
|
||||
protocol = partial(
|
||||
DSMRProtocol,
|
||||
loop,
|
||||
TelegramParser(specification),
|
||||
telegram_callback=telegram_callback,
|
||||
**kwargs
|
||||
)
|
||||
protocol = partial(DSMRProtocol, loop, TelegramParser(specification),
|
||||
telegram_callback=telegram_callback, **kwargs)
|
||||
|
||||
return protocol, serial_settings
|
||||
|
||||
@ -60,26 +51,22 @@ def create_dsmr_protocol(dsmr_version, telegram_callback, loop=None, **kwargs):
|
||||
def create_dsmr_reader(port, dsmr_version, telegram_callback, loop=None):
|
||||
"""Creates a DSMR asyncio protocol coroutine using serial port."""
|
||||
protocol, serial_settings = create_dsmr_protocol(
|
||||
dsmr_version, telegram_callback, loop=None
|
||||
)
|
||||
serial_settings["url"] = port
|
||||
dsmr_version, telegram_callback, loop=None)
|
||||
serial_settings['url'] = port
|
||||
|
||||
conn = create_serial_connection(loop, protocol, **serial_settings)
|
||||
return conn
|
||||
|
||||
|
||||
def create_tcp_dsmr_reader(
|
||||
host, port, dsmr_version, telegram_callback, loop=None, keep_alive_interval=None
|
||||
):
|
||||
def create_tcp_dsmr_reader(host, port, dsmr_version,
|
||||
telegram_callback, loop=None,
|
||||
keep_alive_interval=None):
|
||||
"""Creates a DSMR asyncio protocol coroutine using TCP connection."""
|
||||
if not loop:
|
||||
loop = asyncio.get_event_loop()
|
||||
protocol, _ = create_dsmr_protocol(
|
||||
dsmr_version,
|
||||
telegram_callback,
|
||||
loop=loop,
|
||||
keep_alive_interval=keep_alive_interval,
|
||||
)
|
||||
dsmr_version, telegram_callback, loop=loop,
|
||||
keep_alive_interval=keep_alive_interval)
|
||||
conn = loop.create_connection(protocol, host, port)
|
||||
return conn
|
||||
|
||||
@ -90,9 +77,8 @@ class DSMRProtocol(asyncio.Protocol):
|
||||
transport = None
|
||||
telegram_callback = None
|
||||
|
||||
def __init__(
|
||||
self, loop, telegram_parser, telegram_callback=None, keep_alive_interval=None
|
||||
):
|
||||
def __init__(self, loop, telegram_parser,
|
||||
telegram_callback=None, keep_alive_interval=None):
|
||||
"""Initialize class."""
|
||||
self.loop = loop
|
||||
self.log = logging.getLogger(__name__)
|
||||
@ -109,7 +95,7 @@ class DSMRProtocol(asyncio.Protocol):
|
||||
def connection_made(self, transport):
|
||||
"""Just logging for now."""
|
||||
self.transport = transport
|
||||
self.log.debug("connected")
|
||||
self.log.debug('connected')
|
||||
self._active = False
|
||||
if self.loop and self._keep_alive_interval:
|
||||
self.loop.call_later(self._keep_alive_interval, self.keep_alive)
|
||||
@ -118,7 +104,7 @@ class DSMRProtocol(asyncio.Protocol):
|
||||
"""Add incoming data to buffer."""
|
||||
data = data.decode("latin1")
|
||||
self._active = True
|
||||
self.log.debug("received data: %s", data)
|
||||
self.log.debug('received data: %s', data)
|
||||
self.telegram_buffer.append(data)
|
||||
|
||||
for telegram in self.telegram_buffer.get_all():
|
||||
@ -126,26 +112,26 @@ class DSMRProtocol(asyncio.Protocol):
|
||||
|
||||
def keep_alive(self):
|
||||
if self._active:
|
||||
self.log.debug("keep-alive checked")
|
||||
self.log.debug('keep-alive checked')
|
||||
self._active = False
|
||||
if self.loop:
|
||||
self.loop.call_later(self._keep_alive_interval, self.keep_alive)
|
||||
else:
|
||||
self.log.warning("keep-alive check failed")
|
||||
self.log.warning('keep-alive check failed')
|
||||
if self.transport:
|
||||
self.transport.close()
|
||||
|
||||
def connection_lost(self, exc):
|
||||
"""Stop when connection is lost."""
|
||||
if exc:
|
||||
self.log.exception("disconnected due to exception", exc_info=exc)
|
||||
self.log.exception('disconnected due to exception', exc_info=exc)
|
||||
else:
|
||||
self.log.info("disconnected because of close/abort.")
|
||||
self.log.info('disconnected because of close/abort.')
|
||||
self._closed.set()
|
||||
|
||||
def handle_telegram(self, telegram):
|
||||
"""Send off parsed telegram to handling callback."""
|
||||
self.log.debug("got telegram: %s", telegram)
|
||||
self.log.debug('got telegram: %s', telegram)
|
||||
|
||||
try:
|
||||
parsed_telegram = self.telegram_parser.parse(telegram)
|
||||
|
@ -8,57 +8,57 @@ This module contains a mapping of obis references to names.
|
||||
"""
|
||||
|
||||
EN = {
|
||||
obis.P1_MESSAGE_HEADER: "P1_MESSAGE_HEADER",
|
||||
obis.P1_MESSAGE_TIMESTAMP: "P1_MESSAGE_TIMESTAMP",
|
||||
obis.ELECTRICITY_IMPORTED_TOTAL: "ELECTRICITY_IMPORTED_TOTAL",
|
||||
obis.ELECTRICITY_USED_TARIFF_1: "ELECTRICITY_USED_TARIFF_1",
|
||||
obis.ELECTRICITY_USED_TARIFF_2: "ELECTRICITY_USED_TARIFF_2",
|
||||
obis.ELECTRICITY_EXPORTED_TOTAL: "ELECTRICITY_EXPORTED_TOTAL",
|
||||
obis.ELECTRICITY_DELIVERED_TARIFF_1: "ELECTRICITY_DELIVERED_TARIFF_1",
|
||||
obis.ELECTRICITY_DELIVERED_TARIFF_2: "ELECTRICITY_DELIVERED_TARIFF_2",
|
||||
obis.ELECTRICITY_ACTIVE_TARIFF: "ELECTRICITY_ACTIVE_TARIFF",
|
||||
obis.EQUIPMENT_IDENTIFIER: "EQUIPMENT_IDENTIFIER",
|
||||
obis.CURRENT_ELECTRICITY_USAGE: "CURRENT_ELECTRICITY_USAGE",
|
||||
obis.CURRENT_ELECTRICITY_DELIVERY: "CURRENT_ELECTRICITY_DELIVERY",
|
||||
obis.LONG_POWER_FAILURE_COUNT: "LONG_POWER_FAILURE_COUNT",
|
||||
obis.SHORT_POWER_FAILURE_COUNT: "SHORT_POWER_FAILURE_COUNT",
|
||||
obis.POWER_EVENT_FAILURE_LOG: "POWER_EVENT_FAILURE_LOG",
|
||||
obis.VOLTAGE_SAG_L1_COUNT: "VOLTAGE_SAG_L1_COUNT",
|
||||
obis.VOLTAGE_SAG_L2_COUNT: "VOLTAGE_SAG_L2_COUNT",
|
||||
obis.VOLTAGE_SAG_L3_COUNT: "VOLTAGE_SAG_L3_COUNT",
|
||||
obis.VOLTAGE_SWELL_L1_COUNT: "VOLTAGE_SWELL_L1_COUNT",
|
||||
obis.VOLTAGE_SWELL_L2_COUNT: "VOLTAGE_SWELL_L2_COUNT",
|
||||
obis.VOLTAGE_SWELL_L3_COUNT: "VOLTAGE_SWELL_L3_COUNT",
|
||||
obis.INSTANTANEOUS_VOLTAGE_L1: "INSTANTANEOUS_VOLTAGE_L1",
|
||||
obis.INSTANTANEOUS_VOLTAGE_L2: "INSTANTANEOUS_VOLTAGE_L2",
|
||||
obis.INSTANTANEOUS_VOLTAGE_L3: "INSTANTANEOUS_VOLTAGE_L3",
|
||||
obis.INSTANTANEOUS_CURRENT_L1: "INSTANTANEOUS_CURRENT_L1",
|
||||
obis.INSTANTANEOUS_CURRENT_L2: "INSTANTANEOUS_CURRENT_L2",
|
||||
obis.INSTANTANEOUS_CURRENT_L3: "INSTANTANEOUS_CURRENT_L3",
|
||||
obis.TEXT_MESSAGE_CODE: "TEXT_MESSAGE_CODE",
|
||||
obis.TEXT_MESSAGE: "TEXT_MESSAGE",
|
||||
obis.DEVICE_TYPE: "DEVICE_TYPE",
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: "INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE",
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: "INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE",
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: "INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE",
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: "INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE",
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: "INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE",
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: "INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE",
|
||||
obis.EQUIPMENT_IDENTIFIER_GAS: "EQUIPMENT_IDENTIFIER_GAS",
|
||||
obis.HOURLY_GAS_METER_READING: "HOURLY_GAS_METER_READING",
|
||||
obis.GAS_METER_READING: "GAS_METER_READING",
|
||||
obis.ACTUAL_TRESHOLD_ELECTRICITY: "ACTUAL_TRESHOLD_ELECTRICITY",
|
||||
obis.ACTUAL_SWITCH_POSITION: "ACTUAL_SWITCH_POSITION",
|
||||
obis.VALVE_POSITION_GAS: "VALVE_POSITION_GAS",
|
||||
obis.BELGIUM_HOURLY_GAS_METER_READING: "BELGIUM_HOURLY_GAS_METER_READING",
|
||||
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: "LUXEMBOURG_EQUIPMENT_IDENTIFIER",
|
||||
obis.LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL: "LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL",
|
||||
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: "LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL",
|
||||
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: "SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL",
|
||||
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: "SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL",
|
||||
obis.Q3D_EQUIPMENT_IDENTIFIER: "Q3D_EQUIPMENT_IDENTIFIER",
|
||||
obis.Q3D_EQUIPMENT_STATE: "Q3D_EQUIPMENT_STATE",
|
||||
obis.Q3D_EQUIPMENT_SERIALNUMBER: "Q3D_EQUIPMENT_SERIALNUMBER",
|
||||
obis.P1_MESSAGE_HEADER: 'P1_MESSAGE_HEADER',
|
||||
obis.P1_MESSAGE_TIMESTAMP: 'P1_MESSAGE_TIMESTAMP',
|
||||
obis.ELECTRICITY_IMPORTED_TOTAL: 'ELECTRICITY_IMPORTED_TOTAL',
|
||||
obis.ELECTRICITY_USED_TARIFF_1: 'ELECTRICITY_USED_TARIFF_1',
|
||||
obis.ELECTRICITY_USED_TARIFF_2: 'ELECTRICITY_USED_TARIFF_2',
|
||||
obis.ELECTRICITY_EXPORTED_TOTAL: 'ELECTRICITY_EXPORTED_TOTAL',
|
||||
obis.ELECTRICITY_DELIVERED_TARIFF_1: 'ELECTRICITY_DELIVERED_TARIFF_1',
|
||||
obis.ELECTRICITY_DELIVERED_TARIFF_2: 'ELECTRICITY_DELIVERED_TARIFF_2',
|
||||
obis.ELECTRICITY_ACTIVE_TARIFF: 'ELECTRICITY_ACTIVE_TARIFF',
|
||||
obis.EQUIPMENT_IDENTIFIER: 'EQUIPMENT_IDENTIFIER',
|
||||
obis.CURRENT_ELECTRICITY_USAGE: 'CURRENT_ELECTRICITY_USAGE',
|
||||
obis.CURRENT_ELECTRICITY_DELIVERY: 'CURRENT_ELECTRICITY_DELIVERY',
|
||||
obis.LONG_POWER_FAILURE_COUNT: 'LONG_POWER_FAILURE_COUNT',
|
||||
obis.SHORT_POWER_FAILURE_COUNT: 'SHORT_POWER_FAILURE_COUNT',
|
||||
obis.POWER_EVENT_FAILURE_LOG: 'POWER_EVENT_FAILURE_LOG',
|
||||
obis.VOLTAGE_SAG_L1_COUNT: 'VOLTAGE_SAG_L1_COUNT',
|
||||
obis.VOLTAGE_SAG_L2_COUNT: 'VOLTAGE_SAG_L2_COUNT',
|
||||
obis.VOLTAGE_SAG_L3_COUNT: 'VOLTAGE_SAG_L3_COUNT',
|
||||
obis.VOLTAGE_SWELL_L1_COUNT: 'VOLTAGE_SWELL_L1_COUNT',
|
||||
obis.VOLTAGE_SWELL_L2_COUNT: 'VOLTAGE_SWELL_L2_COUNT',
|
||||
obis.VOLTAGE_SWELL_L3_COUNT: 'VOLTAGE_SWELL_L3_COUNT',
|
||||
obis.INSTANTANEOUS_VOLTAGE_L1: 'INSTANTANEOUS_VOLTAGE_L1',
|
||||
obis.INSTANTANEOUS_VOLTAGE_L2: 'INSTANTANEOUS_VOLTAGE_L2',
|
||||
obis.INSTANTANEOUS_VOLTAGE_L3: 'INSTANTANEOUS_VOLTAGE_L3',
|
||||
obis.INSTANTANEOUS_CURRENT_L1: 'INSTANTANEOUS_CURRENT_L1',
|
||||
obis.INSTANTANEOUS_CURRENT_L2: 'INSTANTANEOUS_CURRENT_L2',
|
||||
obis.INSTANTANEOUS_CURRENT_L3: 'INSTANTANEOUS_CURRENT_L3',
|
||||
obis.TEXT_MESSAGE_CODE: 'TEXT_MESSAGE_CODE',
|
||||
obis.TEXT_MESSAGE: 'TEXT_MESSAGE',
|
||||
obis.DEVICE_TYPE: 'DEVICE_TYPE',
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: 'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE',
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: 'INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE',
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: 'INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE',
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: 'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE',
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: 'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE',
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: 'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE',
|
||||
obis.EQUIPMENT_IDENTIFIER_GAS: 'EQUIPMENT_IDENTIFIER_GAS',
|
||||
obis.HOURLY_GAS_METER_READING: 'HOURLY_GAS_METER_READING',
|
||||
obis.GAS_METER_READING: 'GAS_METER_READING',
|
||||
obis.ACTUAL_TRESHOLD_ELECTRICITY: 'ACTUAL_TRESHOLD_ELECTRICITY',
|
||||
obis.ACTUAL_SWITCH_POSITION: 'ACTUAL_SWITCH_POSITION',
|
||||
obis.VALVE_POSITION_GAS: 'VALVE_POSITION_GAS',
|
||||
obis.BELGIUM_HOURLY_GAS_METER_READING: 'BELGIUM_HOURLY_GAS_METER_READING',
|
||||
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: 'LUXEMBOURG_EQUIPMENT_IDENTIFIER',
|
||||
obis.LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL: 'LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL',
|
||||
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
|
||||
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL',
|
||||
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
|
||||
obis.Q3D_EQUIPMENT_IDENTIFIER: 'Q3D_EQUIPMENT_IDENTIFIER',
|
||||
obis.Q3D_EQUIPMENT_STATE: 'Q3D_EQUIPMENT_STATE',
|
||||
obis.Q3D_EQUIPMENT_SERIALNUMBER: 'Q3D_EQUIPMENT_SERIALNUMBER',
|
||||
}
|
||||
|
||||
REVERSE_EN = dict([(v, k) for k, v in EN.items()])
|
||||
|
@ -6,76 +6,69 @@ refactored to full line signatures to maintain backwards compatibility.
|
||||
Might be refactored in a backwards incompatible way as soon as proper telegram
|
||||
objects are introduced.
|
||||
"""
|
||||
P1_MESSAGE_HEADER = r"\d-\d:0\.2\.8.+?\r\n"
|
||||
P1_MESSAGE_TIMESTAMP = r"\d-\d:1\.0\.0.+?\r\n"
|
||||
ELECTRICITY_IMPORTED_TOTAL = r"\d-\d:1\.8\.0.+?\r\n"
|
||||
ELECTRICITY_USED_TARIFF_1 = r"\d-\d:1\.8\.1.+?\r\n"
|
||||
ELECTRICITY_USED_TARIFF_2 = r"\d-\d:1\.8\.2.+?\r\n"
|
||||
ELECTRICITY_EXPORTED_TOTAL = r"\d-\d:2\.8\.0.+?\r\n"
|
||||
ELECTRICITY_DELIVERED_TARIFF_1 = r"\d-\d:2\.8\.1.+?\r\n"
|
||||
ELECTRICITY_DELIVERED_TARIFF_2 = r"\d-\d:2\.8\.2.+?\r\n"
|
||||
ELECTRICITY_ACTIVE_TARIFF = r"\d-\d:96\.14\.0.+?\r\n"
|
||||
EQUIPMENT_IDENTIFIER = r"\d-\d:96\.1\.1.+?\r\n"
|
||||
CURRENT_ELECTRICITY_USAGE = r"\d-\d:1\.7\.0.+?\r\n"
|
||||
CURRENT_ELECTRICITY_DELIVERY = r"\d-\d:2\.7\.0.+?\r\n"
|
||||
LONG_POWER_FAILURE_COUNT = r"96\.7\.9.+?\r\n"
|
||||
SHORT_POWER_FAILURE_COUNT = r"96\.7\.21.+?\r\n"
|
||||
POWER_EVENT_FAILURE_LOG = r"99\.97\.0.+?\r\n"
|
||||
VOLTAGE_SAG_L1_COUNT = r"\d-\d:32\.32\.0.+?\r\n"
|
||||
VOLTAGE_SAG_L2_COUNT = r"\d-\d:52\.32\.0.+?\r\n"
|
||||
VOLTAGE_SAG_L3_COUNT = r"\d-\d:72\.32\.0.+?\r\n"
|
||||
VOLTAGE_SWELL_L1_COUNT = r"\d-\d:32\.36\.0.+?\r\n"
|
||||
VOLTAGE_SWELL_L2_COUNT = r"\d-\d:52\.36\.0.+?\r\n"
|
||||
VOLTAGE_SWELL_L3_COUNT = r"\d-\d:72\.36\.0.+?\r\n"
|
||||
INSTANTANEOUS_VOLTAGE_L1 = r"\d-\d:32\.7\.0.+?\r\n"
|
||||
INSTANTANEOUS_VOLTAGE_L2 = r"\d-\d:52\.7\.0.+?\r\n"
|
||||
INSTANTANEOUS_VOLTAGE_L3 = r"\d-\d:72\.7\.0.+?\r\n"
|
||||
INSTANTANEOUS_CURRENT_L1 = r"\d-\d:31\.7\.0.+?\r\n"
|
||||
INSTANTANEOUS_CURRENT_L2 = r"\d-\d:51\.7\.0.+?\r\n"
|
||||
INSTANTANEOUS_CURRENT_L3 = r"\d-\d:71\.7\.0.+?\r\n"
|
||||
TEXT_MESSAGE_CODE = r"\d-\d:96\.13\.1.+?\r\n"
|
||||
TEXT_MESSAGE = r"\d-\d:96\.13\.0.+?\r\n"
|
||||
DEVICE_TYPE = r"\d-\d:24\.1\.0.+?\r\n"
|
||||
INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE = r"\d-\d:21\.7\.0.+?\r\n"
|
||||
INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE = r"\d-\d:41\.7\.0.+?\r\n"
|
||||
INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE = r"\d-\d:61\.7\.0.+?\r\n"
|
||||
INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r"\d-\d:22\.7\.0.+?\r\n"
|
||||
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r"\d-\d:42\.7\.0.+?\r\n"
|
||||
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r"\d-\d:62\.7\.0.+?\r\n"
|
||||
EQUIPMENT_IDENTIFIER_GAS = r"\d-\d:96\.1\.0.+?\r\n"
|
||||
P1_MESSAGE_HEADER = r'\d-\d:0\.2\.8.+?\r\n'
|
||||
P1_MESSAGE_TIMESTAMP = r'\d-\d:1\.0\.0.+?\r\n'
|
||||
ELECTRICITY_IMPORTED_TOTAL = r'\d-\d:1\.8\.0.+?\r\n'
|
||||
ELECTRICITY_USED_TARIFF_1 = r'\d-\d:1\.8\.1.+?\r\n'
|
||||
ELECTRICITY_USED_TARIFF_2 = r'\d-\d:1\.8\.2.+?\r\n'
|
||||
ELECTRICITY_EXPORTED_TOTAL = r'\d-\d:2\.8\.0.+?\r\n'
|
||||
ELECTRICITY_DELIVERED_TARIFF_1 = r'\d-\d:2\.8\.1.+?\r\n'
|
||||
ELECTRICITY_DELIVERED_TARIFF_2 = r'\d-\d:2\.8\.2.+?\r\n'
|
||||
ELECTRICITY_ACTIVE_TARIFF = r'\d-\d:96\.14\.0.+?\r\n'
|
||||
EQUIPMENT_IDENTIFIER = r'\d-\d:96\.1\.1.+?\r\n'
|
||||
CURRENT_ELECTRICITY_USAGE = r'\d-\d:1\.7\.0.+?\r\n'
|
||||
CURRENT_ELECTRICITY_DELIVERY = r'\d-\d:2\.7\.0.+?\r\n'
|
||||
LONG_POWER_FAILURE_COUNT = r'96\.7\.9.+?\r\n'
|
||||
SHORT_POWER_FAILURE_COUNT = r'96\.7\.21.+?\r\n'
|
||||
POWER_EVENT_FAILURE_LOG = r'99\.97\.0.+?\r\n'
|
||||
VOLTAGE_SAG_L1_COUNT = r'\d-\d:32\.32\.0.+?\r\n'
|
||||
VOLTAGE_SAG_L2_COUNT = r'\d-\d:52\.32\.0.+?\r\n'
|
||||
VOLTAGE_SAG_L3_COUNT = r'\d-\d:72\.32\.0.+?\r\n'
|
||||
VOLTAGE_SWELL_L1_COUNT = r'\d-\d:32\.36\.0.+?\r\n'
|
||||
VOLTAGE_SWELL_L2_COUNT = r'\d-\d:52\.36\.0.+?\r\n'
|
||||
VOLTAGE_SWELL_L3_COUNT = r'\d-\d:72\.36\.0.+?\r\n'
|
||||
INSTANTANEOUS_VOLTAGE_L1 = r'\d-\d:32\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_VOLTAGE_L2 = r'\d-\d:52\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_VOLTAGE_L3 = r'\d-\d:72\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_CURRENT_L1 = r'\d-\d:31\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_CURRENT_L2 = r'\d-\d:51\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_CURRENT_L3 = r'\d-\d:71\.7\.0.+?\r\n'
|
||||
TEXT_MESSAGE_CODE = r'\d-\d:96\.13\.1.+?\r\n'
|
||||
TEXT_MESSAGE = r'\d-\d:96\.13\.0.+?\r\n'
|
||||
DEVICE_TYPE = r'\d-\d:24\.1\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE = r'\d-\d:21\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE = r'\d-\d:41\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE = r'\d-\d:61\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r'\d-\d:22\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r'\d-\d:42\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r'\d-\d:62\.7\.0.+?\r\n'
|
||||
EQUIPMENT_IDENTIFIER_GAS = r'\d-\d:96\.1\.0.+?\r\n'
|
||||
# TODO differences between gas meter readings in v3 and lower and v4 and up
|
||||
HOURLY_GAS_METER_READING = r"\d-\d:24\.2\.1.+?\r\n"
|
||||
GAS_METER_READING = r"\d-\d:24\.3\.0.+?\r\n.+?\r\n"
|
||||
ACTUAL_TRESHOLD_ELECTRICITY = r"\d-\d:17\.0\.0.+?\r\n"
|
||||
ACTUAL_SWITCH_POSITION = r"\d-\d:96\.3\.10.+?\r\n"
|
||||
VALVE_POSITION_GAS = r"\d-\d:24\.4\.0.+?\r\n"
|
||||
HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.1.+?\r\n'
|
||||
GAS_METER_READING = r'\d-\d:24\.3\.0.+?\r\n.+?\r\n'
|
||||
ACTUAL_TRESHOLD_ELECTRICITY = r'\d-\d:17\.0\.0.+?\r\n'
|
||||
ACTUAL_SWITCH_POSITION = r'\d-\d:96\.3\.10.+?\r\n'
|
||||
VALVE_POSITION_GAS = r'\d-\d:24\.4\.0.+?\r\n'
|
||||
|
||||
# TODO 17.0.0
|
||||
# TODO 96.3.10
|
||||
|
||||
ELECTRICITY_USED_TARIFF_ALL = (ELECTRICITY_USED_TARIFF_1, ELECTRICITY_USED_TARIFF_2)
|
||||
ELECTRICITY_USED_TARIFF_ALL = (
|
||||
ELECTRICITY_USED_TARIFF_1,
|
||||
ELECTRICITY_USED_TARIFF_2
|
||||
)
|
||||
ELECTRICITY_DELIVERED_TARIFF_ALL = (
|
||||
ELECTRICITY_DELIVERED_TARIFF_1,
|
||||
ELECTRICITY_DELIVERED_TARIFF_2,
|
||||
ELECTRICITY_DELIVERED_TARIFF_2
|
||||
)
|
||||
|
||||
# Alternate codes for foreign countries.
|
||||
BELGIUM_HOURLY_GAS_METER_READING = (
|
||||
r"\d-\d:24\.2\.3.+?\r\n" # Different code, same format.
|
||||
)
|
||||
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r"\d-\d:42\.0\.0.+?\r\n" # Logical device name
|
||||
LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL = (
|
||||
r"\d-\d:1\.8\.0.+?\r\n" # Total imported energy register (P+)
|
||||
)
|
||||
LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = (
|
||||
r"\d-\d:2\.8\.0.+?\r\n" # Total exported energy register (P-)
|
||||
)
|
||||
SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL = (
|
||||
r"\d-\d:1\.8\.0.+?\r\n" # Total imported energy register (P+)
|
||||
)
|
||||
SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = (
|
||||
r"\d-\d:2\.8\.0.+?\r\n" # Total exported energy register (P-)
|
||||
)
|
||||
Q3D_EQUIPMENT_IDENTIFIER = r"\d-\d:0\.0\.0.+?\r\n" # Logical device name
|
||||
Q3D_EQUIPMENT_STATE = r"\d-\d:96\.5\.5.+?\r\n" # Device state (hexadecimal)
|
||||
Q3D_EQUIPMENT_SERIALNUMBER = r"\d-\d:96\.1\.255.+?\r\n" # Device Serialnumber
|
||||
BELGIUM_HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.3.+?\r\n' # Different code, same format.
|
||||
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'\d-\d:42\.0\.0.+?\r\n' # Logical device name
|
||||
LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
|
||||
LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
|
||||
SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
|
||||
SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
|
||||
Q3D_EQUIPMENT_IDENTIFIER = r'\d-\d:0\.0\.0.+?\r\n' # Logical device name
|
||||
Q3D_EQUIPMENT_STATE = r'\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal)
|
||||
Q3D_EQUIPMENT_SERIALNUMBER = r'\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber
|
||||
|
@ -2,18 +2,9 @@ from decimal import Decimal
|
||||
from copy import deepcopy
|
||||
|
||||
from dsmr_parser import obis_references as obis
|
||||
from dsmr_parser.parsers import (
|
||||
CosemParser,
|
||||
ValueParser,
|
||||
MBusParser,
|
||||
ProfileGenericParser,
|
||||
)
|
||||
from dsmr_parser.parsers import CosemParser, ValueParser, MBusParser, ProfileGenericParser
|
||||
from dsmr_parser.value_types import timestamp
|
||||
from dsmr_parser.profile_generic_specifications import (
|
||||
BUFFER_TYPES,
|
||||
PG_HEAD_PARSERS,
|
||||
PG_UNIDENTIFIED_BUFFERTYPE_PARSERS,
|
||||
)
|
||||
from dsmr_parser.profile_generic_specifications import BUFFER_TYPES, PG_HEAD_PARSERS, PG_UNIDENTIFIED_BUFFERTYPE_PARSERS
|
||||
|
||||
"""
|
||||
dsmr_parser.telegram_specifications
|
||||
@ -24,8 +15,8 @@ how the telegram lines are parsed.
|
||||
"""
|
||||
|
||||
V2_2 = {
|
||||
"checksum_support": False,
|
||||
"objects": {
|
||||
'checksum_support': False,
|
||||
'objects': {
|
||||
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
||||
@ -50,14 +41,14 @@ V2_2 = {
|
||||
ValueParser(str), # unit, position 5
|
||||
ValueParser(Decimal), # meter reading, position 6
|
||||
),
|
||||
},
|
||||
}
|
||||
}
|
||||
|
||||
V3 = V2_2
|
||||
|
||||
V4 = {
|
||||
"checksum_support": True,
|
||||
"objects": {
|
||||
'checksum_support': True,
|
||||
'objects': {
|
||||
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
||||
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
||||
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
@ -70,9 +61,10 @@ V4 = {
|
||||
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
||||
obis.SHORT_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.POWER_EVENT_FAILURE_LOG: ProfileGenericParser(
|
||||
BUFFER_TYPES, PG_HEAD_PARSERS, PG_UNIDENTIFIED_BUFFERTYPE_PARSERS
|
||||
),
|
||||
obis.POWER_EVENT_FAILURE_LOG:
|
||||
ProfileGenericParser(BUFFER_TYPES,
|
||||
PG_HEAD_PARSERS,
|
||||
PG_UNIDENTIFIED_BUFFERTYPE_PARSERS),
|
||||
obis.VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SAG_L3_COUNT: CosemParser(ValueParser(int)),
|
||||
@ -93,14 +85,15 @@ V4 = {
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
|
||||
obis.HOURLY_GAS_METER_READING: MBusParser(
|
||||
ValueParser(timestamp), ValueParser(Decimal)
|
||||
),
|
||||
},
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
)
|
||||
}
|
||||
}
|
||||
|
||||
V5 = {
|
||||
"checksum_support": True,
|
||||
"objects": {
|
||||
'checksum_support': True,
|
||||
'objects': {
|
||||
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
||||
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
||||
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
@ -114,9 +107,10 @@ V5 = {
|
||||
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
||||
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.SHORT_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.POWER_EVENT_FAILURE_LOG: ProfileGenericParser(
|
||||
BUFFER_TYPES, PG_HEAD_PARSERS, PG_UNIDENTIFIED_BUFFERTYPE_PARSERS
|
||||
),
|
||||
obis.POWER_EVENT_FAILURE_LOG:
|
||||
ProfileGenericParser(BUFFER_TYPES,
|
||||
PG_HEAD_PARSERS,
|
||||
PG_UNIDENTIFIED_BUFFERTYPE_PARSERS),
|
||||
obis.VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SAG_L3_COUNT: CosemParser(ValueParser(int)),
|
||||
@ -139,46 +133,38 @@ V5 = {
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
|
||||
obis.HOURLY_GAS_METER_READING: MBusParser(
|
||||
ValueParser(timestamp), ValueParser(Decimal)
|
||||
),
|
||||
},
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
)
|
||||
}
|
||||
}
|
||||
|
||||
ALL = (V2_2, V3, V4, V5)
|
||||
|
||||
|
||||
BELGIUM_FLUVIUS = deepcopy(V5)
|
||||
BELGIUM_FLUVIUS["objects"].update(
|
||||
{
|
||||
obis.BELGIUM_HOURLY_GAS_METER_READING: MBusParser(
|
||||
ValueParser(timestamp), ValueParser(Decimal)
|
||||
)
|
||||
}
|
||||
)
|
||||
BELGIUM_FLUVIUS['objects'].update({
|
||||
obis.BELGIUM_HOURLY_GAS_METER_READING: MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
)
|
||||
})
|
||||
|
||||
LUXEMBOURG_SMARTY = deepcopy(V5)
|
||||
LUXEMBOURG_SMARTY["objects"].update(
|
||||
{
|
||||
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
obis.LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL: CosemParser(
|
||||
ValueParser(Decimal)
|
||||
),
|
||||
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: CosemParser(
|
||||
ValueParser(Decimal)
|
||||
),
|
||||
}
|
||||
)
|
||||
LUXEMBOURG_SMARTY['objects'].update({
|
||||
obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
obis.LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
|
||||
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
|
||||
})
|
||||
|
||||
# Source: https://www.energiforetagen.se/globalassets/energiforetagen/det-erbjuder-vi/kurser-och-konferenser/elnat/branschrekommendation-lokalt-granssnitt-v2_0-201912.pdf
|
||||
SWEDEN = {
|
||||
"checksum_support": True,
|
||||
"objects": {
|
||||
'checksum_support': True,
|
||||
'objects': {
|
||||
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
||||
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
||||
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
|
||||
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: CosemParser(
|
||||
ValueParser(Decimal)
|
||||
),
|
||||
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: CosemParser(ValueParser(Decimal)),
|
||||
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
||||
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
||||
@ -193,7 +179,7 @@ SWEDEN = {
|
||||
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
|
||||
},
|
||||
}
|
||||
}
|
||||
|
||||
Q3D = {
|
||||
|
Loading…