Change DSMR 5 and 5B to use DSMR devices (#142)
At least the BE and the NL DSMR devices use MBUS. Therefore we make the MBUS obis reference generic, and convert the V5 telegram to use MBUS values. Finally set self.maxDiff = None to have a full test output on some tests.
This commit is contained in:
parent
fcbcbb30e0
commit
bc35a051f2
@ -69,8 +69,25 @@ ACTUAL_TRESHOLD_ELECTRICITY = r'^\d-\d:17\.0\.0.+?\r\n'
|
||||
ACTUAL_SWITCH_POSITION = r'^\d-\d:96\.3\.10.+?\r\n'
|
||||
VALVE_POSITION_GAS = r'^\d-\d:24\.4\.0.+?\r\n'
|
||||
|
||||
# Multiple 'slaves' can be linked to the main device.
|
||||
# The type is reported on 24.1.0
|
||||
# Specifications are in EN 13757-3
|
||||
# For example: Water mater = 7, Gas meter = 3
|
||||
# Identifier is on 96.1.0 (in NL for ex) or
|
||||
# on 96.1.1 (in BE for ex)
|
||||
# The values are reported on 24.2.1
|
||||
# With an exception in Belgium for the GAS meter
|
||||
# Be aware that for the gas volume, another OBIS-code is published
|
||||
# than the one listed in section 7 of DSMR P1.
|
||||
# This is due to the fact that in Belgium the not-temperature
|
||||
# corrected gas volume is used while in the Netherlands,
|
||||
# the temperature corrected gas volume is used.
|
||||
MBUS_DEVICE_TYPE = r'^\d-[1-9]:24\.1\.0.+?\r\n'
|
||||
MBUS_EQUIPMENT_IDENTIFIER = r'^\d-[1-9]:96\.1\.[01].+?\r\n'
|
||||
MBUS_VALVE_POSITION = r'^\d-[1-9]:24\.4\.0.+?\r\n'
|
||||
MBUS_METER_READING = r'^\d-[1-9]:24\.2\.[13].+?\r\n'
|
||||
|
||||
# TODO 17.0.0
|
||||
# TODO 96.3.10
|
||||
|
||||
ELECTRICITY_USED_TARIFF_ALL = (
|
||||
ELECTRICITY_USED_TARIFF_1,
|
||||
@ -92,36 +109,6 @@ BELGIUM_CURRENT_AVERAGE_DEMAND = r'^\d-\d:1\.4\.0.+?\r\n'
|
||||
BELGIUM_MAXIMUM_DEMAND_MONTH = r'^\d-\d:1\.6\.0.+?\r\n'
|
||||
BELGIUM_MAXIMUM_DEMAND_13_MONTHS = r'^\d-\d:98\.1\.0.+?\r\n'
|
||||
|
||||
# Multiple 'slaves' can be linked to the main device.
|
||||
# Mostly MBUS1 = GAS METER with values on 24.2.3
|
||||
# While WATER METER reports it's values on 24.2.1
|
||||
# The GAS METER also reports its valve state on 24.4.0
|
||||
# Dev type for gas = 7 and water = 8
|
||||
BELGIUM_MBUS1_DEVICE_TYPE = r'^\d-1:24\.1\.0.+?\r\n'
|
||||
BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER = r'^\d-1:96\.1\.1.+?\r\n'
|
||||
BELGIUM_MBUS1_VALVE_POSITION = r'^\d-1:24\.4\.0.+?\r\n'
|
||||
BELGIUM_MBUS1_METER_READING1 = r'^\d-1:24\.2\.1.+?\r\n'
|
||||
BELGIUM_MBUS1_METER_READING2 = r'^\d-1:24\.2\.3.+?\r\n'
|
||||
|
||||
BELGIUM_MBUS2_DEVICE_TYPE = r'^\d-2:24\.1\.0.+?\r\n'
|
||||
BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER = r'^\d-2:96\.1\.1.+?\r\n'
|
||||
BELGIUM_MBUS2_VALVE_POSITION = r'^\d-2:24\.4\.0.+?\r\n'
|
||||
BELGIUM_MBUS2_METER_READING1 = r'^\d-2:24\.2\.1.+?\r\n'
|
||||
BELGIUM_MBUS2_METER_READING2 = r'^\d-2:24\.2\.3.+?\r\n'
|
||||
|
||||
BELGIUM_MBUS3_DEVICE_TYPE = r'^\d-3:24\.1\.0.+?\r\n'
|
||||
BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER = r'^\d-3:96\.1\.1.+?\r\n'
|
||||
BELGIUM_MBUS3_VALVE_POSITION = r'^\d-3:24\.4\.0.+?\r\n'
|
||||
BELGIUM_MBUS3_METER_READING1 = r'^\d-3:24\.2\.1.+?\r\n'
|
||||
BELGIUM_MBUS3_METER_READING2 = r'^\d-3:24\.2\.3.+?\r\n'
|
||||
|
||||
BELGIUM_MBUS4_DEVICE_TYPE = r'^\d-4:24\.1\.0.+?\r\n'
|
||||
BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER = r'^\d-4:96\.1\.1.+?\r\n'
|
||||
BELGIUM_MBUS4_VALVE_POSITION = r'^\d-4:24\.4\.0.+?\r\n'
|
||||
BELGIUM_MBUS4_METER_READING1 = r'^\d-4:24\.2\.1.+?\r\n'
|
||||
BELGIUM_MBUS4_METER_READING2 = r'^\d-4:24\.2\.3.+?\r\n'
|
||||
|
||||
|
||||
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'^\d-\d:42\.0\.0.+?\r\n' # Logical device name
|
||||
|
||||
Q3D_EQUIPMENT_IDENTIFIER = r'^\d-\d:0\.0\.0.+?\r\n' # Logical device name
|
||||
|
@ -28,12 +28,12 @@ class Telegram(dict):
|
||||
def add(self, obis_reference, dsmr_object, obis_name):
|
||||
# Update name mapping used to get value by attribute. Example: telegram.P1_MESSAGE_HEADER
|
||||
setattr(self, obis_name, dsmr_object)
|
||||
if obis_name not in self._item_names: # TODO repeating obis references
|
||||
self._item_names.append(obis_name)
|
||||
|
||||
# TODO isinstance check: MaxDemandParser (BELGIUM_MAXIMUM_DEMAND_13_MONTHS) returns a list
|
||||
if isinstance(dsmr_object, DSMRObject) and dsmr_object.is_mbus_reading:
|
||||
self._add_mbus(obis_reference, dsmr_object, obis_name)
|
||||
elif obis_name not in self._item_names: # TODO repeating obis references
|
||||
self._item_names.append(obis_name)
|
||||
|
||||
# Fill dict which is only used for backwards compatibility
|
||||
if obis_reference not in self:
|
||||
|
@ -430,11 +430,6 @@ V5 = {
|
||||
'value_parser': CosemParser(ValueParser(str)),
|
||||
'value_name': 'TEXT_MESSAGE'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.DEVICE_TYPE,
|
||||
'value_parser': CosemParser(ValueParser(int)),
|
||||
'value_name': 'DEVICE_TYPE'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE,
|
||||
'value_parser': CosemParser(ValueParser(Decimal)),
|
||||
@ -466,17 +461,27 @@ V5 = {
|
||||
'value_name': 'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.EQUIPMENT_IDENTIFIER_GAS,
|
||||
'value_parser': CosemParser(ValueParser(str)),
|
||||
'value_name': 'EQUIPMENT_IDENTIFIER_GAS'
|
||||
'obis_reference': obis.MBUS_DEVICE_TYPE,
|
||||
'value_parser': CosemParser(ValueParser(int)),
|
||||
'value_name': 'MBUS_DEVICE_TYPE'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.HOURLY_GAS_METER_READING,
|
||||
'obis_reference': obis.MBUS_EQUIPMENT_IDENTIFIER,
|
||||
'value_parser': CosemParser(ValueParser(str)),
|
||||
'value_name': 'MBUS_EQUIPMENT_IDENTIFIER'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.MBUS_VALVE_POSITION,
|
||||
'value_parser': CosemParser(ValueParser(int)),
|
||||
'value_name': 'MBUS_VALVE_POSITION'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.MBUS_METER_READING,
|
||||
'value_parser': MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
),
|
||||
'value_name': 'HOURLY_GAS_METER_READING'
|
||||
'value_name': 'MBUS_METER_READING'
|
||||
},
|
||||
]
|
||||
}
|
||||
@ -624,11 +629,6 @@ BELGIUM_FLUVIUS = {
|
||||
'value_parser': CosemParser(ValueParser(Decimal)),
|
||||
'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.ACTUAL_TRESHOLD_ELECTRICITY,
|
||||
'value_parser': CosemParser(ValueParser(Decimal)),
|
||||
'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.FUSE_THRESHOLD_L1,
|
||||
'value_parser': CosemParser(ValueParser(Decimal)),
|
||||
@ -640,128 +640,27 @@ BELGIUM_FLUVIUS = {
|
||||
'value_name': 'TEXT_MESSAGE'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS1_DEVICE_TYPE,
|
||||
'obis_reference': obis.MBUS_DEVICE_TYPE,
|
||||
'value_parser': CosemParser(ValueParser(int)),
|
||||
'value_name': 'BELGIUM_MBUS1_DEVICE_TYPE'
|
||||
'value_name': 'MBUS_DEVICE_TYPE'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER,
|
||||
'obis_reference': obis.MBUS_EQUIPMENT_IDENTIFIER,
|
||||
'value_parser': CosemParser(ValueParser(str)),
|
||||
'value_name': 'BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER'
|
||||
'value_name': 'MBUS_EQUIPMENT_IDENTIFIER'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS1_VALVE_POSITION,
|
||||
'obis_reference': obis.MBUS_VALVE_POSITION,
|
||||
'value_parser': CosemParser(ValueParser(int)),
|
||||
'value_name': 'BELGIUM_MBUS1_VALVE_POSITION'
|
||||
'value_name': 'MBUS_VALVE_POSITION'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS1_METER_READING1,
|
||||
'obis_reference': obis.MBUS_METER_READING,
|
||||
'value_parser': MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
),
|
||||
'value_name': 'BELGIUM_MBUS1_METER_READING1'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS1_METER_READING2,
|
||||
'value_parser': MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
),
|
||||
'value_name': 'BELGIUM_MBUS1_METER_READING2'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS2_DEVICE_TYPE,
|
||||
'value_parser': CosemParser(ValueParser(int)),
|
||||
'value_name': 'BELGIUM_MBUS2_DEVICE_TYPE'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER,
|
||||
'value_parser': CosemParser(ValueParser(str)),
|
||||
'value_name': 'BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS2_VALVE_POSITION,
|
||||
'value_parser': CosemParser(ValueParser(int)),
|
||||
'value_name': 'BELGIUM_MBUS2_VALVE_POSITION'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS2_METER_READING1,
|
||||
'value_parser': MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
),
|
||||
'value_name': 'BELGIUM_MBUS2_METER_READING1'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS2_METER_READING2,
|
||||
'value_parser': MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
),
|
||||
'value_name': 'BELGIUM_MBUS2_METER_READING2'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS3_DEVICE_TYPE,
|
||||
'value_parser': CosemParser(ValueParser(int)),
|
||||
'value_name': 'BELGIUM_MBUS3_DEVICE_TYPE'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER,
|
||||
'value_parser': CosemParser(ValueParser(str)),
|
||||
'value_name': 'BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS3_VALVE_POSITION,
|
||||
'value_parser': CosemParser(ValueParser(int)),
|
||||
'value_name': 'BELGIUM_MBUS3_VALVE_POSITION'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS3_METER_READING1,
|
||||
'value_parser': MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
),
|
||||
'value_name': 'BELGIUM_MBUS3_METER_READING1'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS3_METER_READING2,
|
||||
'value_parser': MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
),
|
||||
'value_name': 'BELGIUM_MBUS3_METER_READING2'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS4_DEVICE_TYPE,
|
||||
'value_parser': CosemParser(ValueParser(int)),
|
||||
'value_name': 'BELGIUM_MBUS4_DEVICE_TYPE'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER,
|
||||
'value_parser': CosemParser(ValueParser(str)),
|
||||
'value_name': 'BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS4_VALVE_POSITION,
|
||||
'value_parser': CosemParser(ValueParser(int)),
|
||||
'value_name': 'BELGIUM_MBUS4_VALVE_POSITION'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS4_METER_READING1,
|
||||
'value_parser': MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
),
|
||||
'value_name': 'BELGIUM_MBUS4_METER_READING1'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MBUS4_METER_READING2,
|
||||
'value_parser': MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
),
|
||||
'value_name': 'BELGIUM_MBUS4_METER_READING2'
|
||||
'value_name': 'MBUS_METER_READING'
|
||||
},
|
||||
]
|
||||
}
|
||||
|
@ -15,59 +15,59 @@ class MbusDeviceTest(unittest.TestCase):
|
||||
device_type_parser = [
|
||||
object["value_parser"]
|
||||
for object in v5_objects
|
||||
if object["obis_reference"] == obis_references.DEVICE_TYPE
|
||||
if object["obis_reference"] == obis_references.MBUS_DEVICE_TYPE
|
||||
][0]
|
||||
device_type = device_type_parser.parse('0-2:24.1.0(003)\r\n')
|
||||
|
||||
equipment_parser = [
|
||||
object["value_parser"]
|
||||
for object in v5_objects
|
||||
if object["obis_reference"] == obis_references.EQUIPMENT_IDENTIFIER_GAS
|
||||
if object["obis_reference"] == obis_references.MBUS_EQUIPMENT_IDENTIFIER
|
||||
][0]
|
||||
equipment = equipment_parser.parse('0-2:96.1.0(4730303339303031393336393930363139)\r\n')
|
||||
|
||||
gas_reading_parser = [
|
||||
object["value_parser"]
|
||||
for object in v5_objects
|
||||
if object["obis_reference"] == obis_references.HOURLY_GAS_METER_READING
|
||||
if object["obis_reference"] == obis_references.MBUS_METER_READING
|
||||
][0]
|
||||
gas_reading = gas_reading_parser.parse('0-2:24.2.1(200426223001S)(00246.138*m3)\r\n')
|
||||
|
||||
mbus_device = MbusDevice(channel_id=1)
|
||||
mbus_device.add(obis_references.DEVICE_TYPE, device_type, "DEVICE_TYPE")
|
||||
mbus_device.add(obis_references.EQUIPMENT_IDENTIFIER_GAS, equipment, "EQUIPMENT_IDENTIFIER_GAS")
|
||||
mbus_device.add(obis_references.HOURLY_GAS_METER_READING, gas_reading, "HOURLY_GAS_METER_READING")
|
||||
mbus_device = MbusDevice(channel_id=2)
|
||||
mbus_device.add(obis_references.MBUS_DEVICE_TYPE, device_type, "MBUS_DEVICE_TYPE")
|
||||
mbus_device.add(obis_references.MBUS_EQUIPMENT_IDENTIFIER, equipment, "MBUS_EQUIPMENT_IDENTIFIER")
|
||||
mbus_device.add(obis_references.MBUS_METER_READING, gas_reading, "MBUS_METER_READING")
|
||||
|
||||
self.mbus_device = mbus_device
|
||||
|
||||
def test_attributes(self):
|
||||
self.assertEqual(self.mbus_device.DEVICE_TYPE.value, 3)
|
||||
self.assertEqual(self.mbus_device.DEVICE_TYPE.unit, None)
|
||||
self.assertEqual(self.mbus_device.MBUS_DEVICE_TYPE.value, 3)
|
||||
self.assertEqual(self.mbus_device.MBUS_DEVICE_TYPE.unit, None)
|
||||
|
||||
self.assertEqual(self.mbus_device.EQUIPMENT_IDENTIFIER_GAS.value,
|
||||
self.assertEqual(self.mbus_device.MBUS_EQUIPMENT_IDENTIFIER.value,
|
||||
'4730303339303031393336393930363139')
|
||||
self.assertEqual(self.mbus_device.EQUIPMENT_IDENTIFIER_GAS.unit, None)
|
||||
self.assertEqual(self.mbus_device.MBUS_EQUIPMENT_IDENTIFIER.unit, None)
|
||||
|
||||
self.assertEqual(self.mbus_device.HOURLY_GAS_METER_READING.value, Decimal('246.138'))
|
||||
self.assertEqual(self.mbus_device.HOURLY_GAS_METER_READING.unit, 'm3')
|
||||
self.assertEqual(self.mbus_device.MBUS_METER_READING.value, Decimal('246.138'))
|
||||
self.assertEqual(self.mbus_device.MBUS_METER_READING.unit, 'm3')
|
||||
|
||||
def test_to_json(self):
|
||||
self.assertEqual(
|
||||
json.loads(self.mbus_device.to_json()),
|
||||
{
|
||||
'CHANNEL_ID': 1,
|
||||
'DEVICE_TYPE': {'value': 3, 'unit': None},
|
||||
'EQUIPMENT_IDENTIFIER_GAS': {'value': '4730303339303031393336393930363139', 'unit': None},
|
||||
'HOURLY_GAS_METER_READING': {'datetime': '2020-04-26T20:30:01+00:00', 'value': 246.138, 'unit': 'm3'}}
|
||||
'CHANNEL_ID': 2,
|
||||
'MBUS_DEVICE_TYPE': {'value': 3, 'unit': None},
|
||||
'MBUS_EQUIPMENT_IDENTIFIER': {'value': '4730303339303031393336393930363139', 'unit': None},
|
||||
'MBUS_METER_READING': {'datetime': '2020-04-26T20:30:01+00:00', 'value': 246.138, 'unit': 'm3'}}
|
||||
)
|
||||
|
||||
def test_str(self):
|
||||
self.assertEqual(
|
||||
str(self.mbus_device),
|
||||
(
|
||||
'MBUS DEVICE (channel 1)\n'
|
||||
'\tDEVICE_TYPE: 3 [None]\n'
|
||||
'\tEQUIPMENT_IDENTIFIER_GAS: 4730303339303031393336393930363139 [None]\n'
|
||||
'\tHOURLY_GAS_METER_READING: 246.138 [m3] at 2020-04-26T20:30:01+00:00\n'
|
||||
'MBUS DEVICE (channel 2)\n'
|
||||
'\tMBUS_DEVICE_TYPE: 3 [None]\n'
|
||||
'\tMBUS_EQUIPMENT_IDENTIFIER: 4730303339303031393336393930363139 [None]\n'
|
||||
'\tMBUS_METER_READING: 246.138 [m3] at 2020-04-26T20:30:01+00:00\n'
|
||||
)
|
||||
)
|
||||
|
@ -216,14 +216,6 @@ class TelegramTest(unittest.TestCase):
|
||||
value_type=Decimal,
|
||||
value_val=Decimal('2'))
|
||||
|
||||
# DEVICE_TYPE (0-x:24.1.0)
|
||||
self.verify_telegram_item(telegram,
|
||||
'DEVICE_TYPE',
|
||||
object_type=CosemObject,
|
||||
unit_val=None,
|
||||
value_type=int,
|
||||
value_val=3)
|
||||
|
||||
# INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE (1-0:21.7.0)
|
||||
self.verify_telegram_item(telegram,
|
||||
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE',
|
||||
@ -272,7 +264,15 @@ class TelegramTest(unittest.TestCase):
|
||||
value_type=Decimal,
|
||||
value_val=Decimal('0'))
|
||||
|
||||
# EQUIPMENT_IDENTIFIER_GAS (0-x:96.1.0)
|
||||
# DEVICE_TYPE (0-1:24.1.0)
|
||||
self.verify_telegram_item(telegram,
|
||||
'DEVICE_TYPE',
|
||||
object_type=CosemObject,
|
||||
unit_val=None,
|
||||
value_type=int,
|
||||
value_val=3)
|
||||
|
||||
# EQUIPMENT_IDENTIFIER_GAS (0-1:96.1.0)
|
||||
self.verify_telegram_item(telegram,
|
||||
'EQUIPMENT_IDENTIFIER_GAS',
|
||||
object_type=CosemObject,
|
||||
@ -340,28 +340,28 @@ class TelegramTest(unittest.TestCase):
|
||||
self.assertEqual(len(mbus_devices), 2)
|
||||
|
||||
mbus_device_1 = mbus_devices[0]
|
||||
self.assertEqual(mbus_device_1.DEVICE_TYPE.value, 3)
|
||||
self.assertEqual(mbus_device_1.EQUIPMENT_IDENTIFIER_GAS.value, None)
|
||||
self.assertEqual(mbus_device_1.HOURLY_GAS_METER_READING.value, Decimal('0'))
|
||||
self.assertEqual(mbus_device_1.MBUS_DEVICE_TYPE.value, 3)
|
||||
self.assertEqual(mbus_device_1.MBUS_EQUIPMENT_IDENTIFIER.value, None)
|
||||
self.assertEqual(mbus_device_1.MBUS_METER_READING.value, Decimal('0'))
|
||||
|
||||
mbus_device_2 = mbus_devices[1]
|
||||
self.assertEqual(mbus_device_2.DEVICE_TYPE.value, 3)
|
||||
self.assertEqual(mbus_device_2.EQUIPMENT_IDENTIFIER_GAS.value, '4730303339303031393336393930363139')
|
||||
self.assertEqual(mbus_device_2.HOURLY_GAS_METER_READING.value, Decimal('246.138'))
|
||||
self.assertEqual(mbus_device_2.MBUS_DEVICE_TYPE.value, 3)
|
||||
self.assertEqual(mbus_device_2.MBUS_EQUIPMENT_IDENTIFIER.value, '4730303339303031393336393930363139')
|
||||
self.assertEqual(mbus_device_2.MBUS_METER_READING.value, Decimal('246.138'))
|
||||
|
||||
def test_get_mbus_device_by_channel(self):
|
||||
parser = TelegramParser(telegram_specifications.V5)
|
||||
telegram = parser.parse(TELEGRAM_V5_TWO_MBUS)
|
||||
|
||||
mbus_device_1 = telegram.get_mbus_device_by_channel(1)
|
||||
self.assertEqual(mbus_device_1.DEVICE_TYPE.value, 3)
|
||||
self.assertEqual(mbus_device_1.EQUIPMENT_IDENTIFIER_GAS.value, None)
|
||||
self.assertEqual(mbus_device_1.HOURLY_GAS_METER_READING.value, Decimal('0'))
|
||||
self.assertEqual(mbus_device_1.MBUS_DEVICE_TYPE.value, 3)
|
||||
self.assertEqual(mbus_device_1.MBUS_EQUIPMENT_IDENTIFIER.value, None)
|
||||
self.assertEqual(mbus_device_1.MBUS_METER_READING.value, Decimal('0'))
|
||||
|
||||
mbus_device_2 = telegram.get_mbus_device_by_channel(2)
|
||||
self.assertEqual(mbus_device_2.DEVICE_TYPE.value, 3)
|
||||
self.assertEqual(mbus_device_2.EQUIPMENT_IDENTIFIER_GAS.value, '4730303339303031393336393930363139')
|
||||
self.assertEqual(mbus_device_2.HOURLY_GAS_METER_READING.value, Decimal('246.138'))
|
||||
self.assertEqual(mbus_device_2.MBUS_DEVICE_TYPE.value, 3)
|
||||
self.assertEqual(mbus_device_2.MBUS_EQUIPMENT_IDENTIFIER.value, '4730303339303031393336393930363139')
|
||||
self.assertEqual(mbus_device_2.MBUS_METER_READING.value, Decimal('246.138'))
|
||||
|
||||
def test_without_mbus_devices(self):
|
||||
parser = TelegramParser(telegram_specifications.V5, apply_checksum_validation=False)
|
||||
@ -375,11 +375,12 @@ class TelegramTest(unittest.TestCase):
|
||||
telegram = parser.parse(TELEGRAM_V5)
|
||||
json_data = json.loads(telegram.to_json())
|
||||
|
||||
self.maxDiff = None
|
||||
|
||||
self.assertEqual(
|
||||
json_data,
|
||||
{'CURRENT_ELECTRICITY_DELIVERY': {'unit': 'kW', 'value': 0.0},
|
||||
'CURRENT_ELECTRICITY_USAGE': {'unit': 'kW', 'value': 0.244},
|
||||
'DEVICE_TYPE': {'unit': None, 'value': 3},
|
||||
'ELECTRICITY_ACTIVE_TARIFF': {'unit': None, 'value': '0002'},
|
||||
'ELECTRICITY_DELIVERED_TARIFF_1': {'unit': 'kWh', 'value': 2.444},
|
||||
'ELECTRICITY_DELIVERED_TARIFF_2': {'unit': 'kWh', 'value': 0.0},
|
||||
@ -387,10 +388,6 @@ class TelegramTest(unittest.TestCase):
|
||||
'ELECTRICITY_USED_TARIFF_2': {'unit': 'kWh', 'value': 2.399},
|
||||
'EQUIPMENT_IDENTIFIER': {'unit': None,
|
||||
'value': '4B384547303034303436333935353037'},
|
||||
'EQUIPMENT_IDENTIFIER_GAS': {'unit': None, 'value': None},
|
||||
'HOURLY_GAS_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00',
|
||||
'unit': 'm3',
|
||||
'value': 0.107},
|
||||
'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE': {'unit': 'kW', 'value': 0.0},
|
||||
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE': {'unit': 'kW', 'value': 0.07},
|
||||
'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE': {'unit': 'kW', 'value': 0.0},
|
||||
@ -405,15 +402,16 @@ class TelegramTest(unittest.TestCase):
|
||||
'INSTANTANEOUS_VOLTAGE_L3': {'unit': 'V', 'value': 229.0},
|
||||
'LONG_POWER_FAILURE_COUNT': {'unit': None, 'value': 0},
|
||||
'MBUS_DEVICES': [{'CHANNEL_ID': 1,
|
||||
'DEVICE_TYPE': {'unit': None, 'value': 3},
|
||||
'EQUIPMENT_IDENTIFIER_GAS': {'unit': None,
|
||||
'MBUS_DEVICE_TYPE': {'unit': None, 'value': 3},
|
||||
'MBUS_EQUIPMENT_IDENTIFIER': {'unit': None,
|
||||
'value': '3232323241424344313233343536373839'},
|
||||
'HOURLY_GAS_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00',
|
||||
'MBUS_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00',
|
||||
'unit': 'm3',
|
||||
'value': 0.107}},
|
||||
{'CHANNEL_ID': 2,
|
||||
'DEVICE_TYPE': {'unit': None, 'value': 3},
|
||||
'EQUIPMENT_IDENTIFIER_GAS': {'unit': None, 'value': None}}],
|
||||
'MBUS_DEVICE_TYPE': {'unit': None, 'value': 3},
|
||||
'MBUS_EQUIPMENT_IDENTIFIER': {'unit': None,
|
||||
'value': None}}],
|
||||
'P1_MESSAGE_HEADER': {'unit': None, 'value': '50'},
|
||||
'P1_MESSAGE_TIMESTAMP': {'unit': None, 'value': '2017-01-02T18:20:02+00:00'},
|
||||
'POWER_EVENT_FAILURE_LOG': {'buffer': [],
|
||||
@ -433,6 +431,8 @@ class TelegramTest(unittest.TestCase):
|
||||
parser = TelegramParser(telegram_specifications.V5)
|
||||
telegram = parser.parse(TELEGRAM_V5)
|
||||
|
||||
self.maxDiff = None
|
||||
|
||||
self.assertEqual(
|
||||
str(telegram),
|
||||
(
|
||||
@ -463,22 +463,19 @@ class TelegramTest(unittest.TestCase):
|
||||
'INSTANTANEOUS_CURRENT_L2: 0.44 [A]\n'
|
||||
'INSTANTANEOUS_CURRENT_L3: 0.86 [A]\n'
|
||||
'TEXT_MESSAGE: None [None]\n'
|
||||
'DEVICE_TYPE: 3 [None]\n'
|
||||
'MBUS DEVICE (channel 1)\n'
|
||||
' DEVICE_TYPE: 3 [None]\n'
|
||||
' EQUIPMENT_IDENTIFIER_GAS: 3232323241424344313233343536373839 [None]\n'
|
||||
' HOURLY_GAS_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n'
|
||||
'MBUS DEVICE (channel 2)\n'
|
||||
' DEVICE_TYPE: 3 [None]\n'
|
||||
' EQUIPMENT_IDENTIFIER_GAS: None [None]\n'
|
||||
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: 0.070 [kW]\n'
|
||||
'INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: 0.032 [kW]\n'
|
||||
'INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: 0.142 [kW]\n'
|
||||
'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: 0.000 [kW]\n'
|
||||
'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: 0.000 [kW]\n'
|
||||
'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: 0.000 [kW]\n'
|
||||
'EQUIPMENT_IDENTIFIER_GAS: None [None]\n'
|
||||
'HOURLY_GAS_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n'
|
||||
'MBUS DEVICE (channel 1)\n'
|
||||
' MBUS_DEVICE_TYPE: 3 [None]\n'
|
||||
' MBUS_EQUIPMENT_IDENTIFIER: 3232323241424344313233343536373839 [None]\n'
|
||||
' MBUS_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n'
|
||||
'MBUS DEVICE (channel 2)\n'
|
||||
' MBUS_DEVICE_TYPE: 3 [None]\n'
|
||||
' MBUS_EQUIPMENT_IDENTIFIER: None [None]\n'
|
||||
)
|
||||
)
|
||||
|
||||
|
@ -228,47 +228,53 @@ class TelegramParserFluviusTest(unittest.TestCase):
|
||||
assert result.TEXT_MESSAGE.unit is None
|
||||
assert result.TEXT_MESSAGE.value is None
|
||||
|
||||
# BELGIUM_MBUS1_DEVICE_TYPE (0-1:24.1.0)
|
||||
assert isinstance(result.BELGIUM_MBUS1_DEVICE_TYPE, CosemObject)
|
||||
assert result.BELGIUM_MBUS1_DEVICE_TYPE.unit is None
|
||||
assert isinstance(result.BELGIUM_MBUS1_DEVICE_TYPE.value, int)
|
||||
assert result.BELGIUM_MBUS1_DEVICE_TYPE.value == 3
|
||||
# MBUS DEVICE 1
|
||||
mbus1 = result.get_mbus_device_by_channel(1)
|
||||
|
||||
# BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER (0-1:96.1.1)
|
||||
assert isinstance(result.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER, CosemObject)
|
||||
assert result.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER.unit is None
|
||||
assert isinstance(result.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER.value, str)
|
||||
assert result.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER.value == '37464C4F32313139303333373333'
|
||||
# MBUS_DEVICE_TYPE (0-1:24.1.0)
|
||||
assert isinstance(mbus1.MBUS_DEVICE_TYPE, CosemObject)
|
||||
assert mbus1.MBUS_DEVICE_TYPE.unit is None
|
||||
assert isinstance(mbus1.MBUS_DEVICE_TYPE.value, int)
|
||||
assert mbus1.MBUS_DEVICE_TYPE.value == 3
|
||||
|
||||
# BELGIUM_MBUS1_VALVE_POSITION (0-1:24.4.0)
|
||||
assert isinstance(result.BELGIUM_MBUS1_VALVE_POSITION, CosemObject)
|
||||
assert result.BELGIUM_MBUS1_VALVE_POSITION.unit is None
|
||||
assert isinstance(result.BELGIUM_MBUS1_VALVE_POSITION.value, int)
|
||||
assert result.BELGIUM_MBUS1_VALVE_POSITION.value == 1
|
||||
# MBUS_EQUIPMENT_IDENTIFIER (0-1:96.1.1)
|
||||
assert isinstance(mbus1.MBUS_EQUIPMENT_IDENTIFIER, CosemObject)
|
||||
assert mbus1.MBUS_EQUIPMENT_IDENTIFIER.unit is None
|
||||
assert isinstance(mbus1.MBUS_EQUIPMENT_IDENTIFIER.value, str)
|
||||
assert mbus1.MBUS_EQUIPMENT_IDENTIFIER.value == '37464C4F32313139303333373333'
|
||||
|
||||
# BELGIUM_MBUS1_METER_READING2 (0-1:24.2.3)
|
||||
assert isinstance(result.BELGIUM_MBUS1_METER_READING2, MBusObject)
|
||||
assert result.BELGIUM_MBUS1_METER_READING2.unit == 'm3'
|
||||
assert isinstance(result.BELGIUM_MBUS1_METER_READING2.value, Decimal)
|
||||
assert result.BELGIUM_MBUS1_METER_READING2.value == Decimal('112.384')
|
||||
# MBUS_VALVE_POSITION (0-1:24.4.0)
|
||||
assert isinstance(result.MBUS_VALVE_POSITION, CosemObject)
|
||||
assert result.MBUS_VALVE_POSITION.unit is None
|
||||
assert isinstance(result.MBUS_VALVE_POSITION.value, int)
|
||||
assert result.MBUS_VALVE_POSITION.value == 1
|
||||
|
||||
# BELGIUM_MBUS2_DEVICE_TYPE (0-2:24.1.0)
|
||||
assert isinstance(result.BELGIUM_MBUS2_DEVICE_TYPE, CosemObject)
|
||||
assert result.BELGIUM_MBUS2_DEVICE_TYPE.unit is None
|
||||
assert isinstance(result.BELGIUM_MBUS2_DEVICE_TYPE.value, int)
|
||||
assert result.BELGIUM_MBUS2_DEVICE_TYPE.value == 7
|
||||
# MBUS_METER_READING (0-1:24.2.3)
|
||||
assert isinstance(mbus1.MBUS_METER_READING, MBusObject)
|
||||
assert mbus1.MBUS_METER_READING.unit == 'm3'
|
||||
assert isinstance(mbus1.MBUS_METER_READING.value, Decimal)
|
||||
assert mbus1.MBUS_METER_READING.value == Decimal('112.384')
|
||||
|
||||
# BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER (0-2:96.1.1)
|
||||
assert isinstance(result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER, CosemObject)
|
||||
assert result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER.unit is None
|
||||
assert isinstance(result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER.value, str)
|
||||
assert result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER.value == '3853414731323334353637383930'
|
||||
# MBUS DEVICE 2
|
||||
mbus2 = result.get_mbus_device_by_channel(2)
|
||||
|
||||
# BELGIUM_MBUS2_METER_READING1 (0-1:24.2.1)
|
||||
assert isinstance(result.BELGIUM_MBUS2_METER_READING1, MBusObject)
|
||||
assert result.BELGIUM_MBUS2_METER_READING1.unit == 'm3'
|
||||
assert isinstance(result.BELGIUM_MBUS2_METER_READING1.value, Decimal)
|
||||
assert result.BELGIUM_MBUS2_METER_READING1.value == Decimal('872.234')
|
||||
# MBUS_DEVICE_TYPE (0-2:24.1.0)
|
||||
assert isinstance(mbus2.MBUS_DEVICE_TYPE, CosemObject)
|
||||
assert mbus2.MBUS_DEVICE_TYPE.unit is None
|
||||
assert isinstance(mbus2.MBUS_DEVICE_TYPE.value, int)
|
||||
assert mbus2.MBUS_DEVICE_TYPE.value == 7
|
||||
|
||||
# MBUS_EQUIPMENT_IDENTIFIER (0-2:96.1.1)
|
||||
assert isinstance(mbus2.MBUS_EQUIPMENT_IDENTIFIER, CosemObject)
|
||||
assert mbus2.MBUS_EQUIPMENT_IDENTIFIER.unit is None
|
||||
assert isinstance(mbus2.MBUS_EQUIPMENT_IDENTIFIER.value, str)
|
||||
assert mbus2.MBUS_EQUIPMENT_IDENTIFIER.value == '3853414731323334353637383930'
|
||||
|
||||
# MBUS_METER_READING (0-1:24.2.1)
|
||||
assert isinstance(mbus2.MBUS_METER_READING, MBusObject)
|
||||
assert mbus2.MBUS_METER_READING.unit == 'm3'
|
||||
assert isinstance(mbus2.MBUS_METER_READING.value, Decimal)
|
||||
assert mbus2.MBUS_METER_READING.value == Decimal('872.234')
|
||||
|
||||
def test_checksum_valid(self):
|
||||
# No exception is raised.
|
||||
@ -296,6 +302,8 @@ class TelegramParserFluviusTest(unittest.TestCase):
|
||||
telegram = parser.parse(TELEGRAM_FLUVIUS_V171_ALT)
|
||||
json_data = json.loads(telegram.to_json())
|
||||
|
||||
self.maxDiff = None
|
||||
|
||||
self.assertEqual(
|
||||
json_data,
|
||||
{'BELGIUM_VERSION_INFORMATION': {'value': '50217', 'unit': None},
|
||||
@ -338,26 +346,19 @@ class TelegramParserFluviusTest(unittest.TestCase):
|
||||
'ACTUAL_TRESHOLD_ELECTRICITY': {'value': 999.9, 'unit': 'kW'},
|
||||
'FUSE_THRESHOLD_L1': {'value': 999.0, 'unit': 'A'},
|
||||
'TEXT_MESSAGE': {'value': None, 'unit': None},
|
||||
'BELGIUM_MBUS1_DEVICE_TYPE': {'value': 3, 'unit': None},
|
||||
'MBUS_DEVICES': [{'BELGIUM_MBUS1_DEVICE_TYPE': {'value': 3, 'unit': None},
|
||||
'BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER': {'value': '37464C4F32313233303838303237',
|
||||
'MBUS_DEVICES': [{'MBUS_DEVICE_TYPE': {'value': 3, 'unit': None},
|
||||
'MBUS_EQUIPMENT_IDENTIFIER': {'value': '37464C4F32313233303838303237',
|
||||
'unit': None},
|
||||
'BELGIUM_MBUS1_VALVE_POSITION': {'value': 1, 'unit': None},
|
||||
'BELGIUM_MBUS1_METER_READING2': {'datetime': '2023-11-02T11:10:02+00:00',
|
||||
'MBUS_VALVE_POSITION': {'value': 1, 'unit': None},
|
||||
'MBUS_METER_READING': {'datetime': '2023-11-02T11:10:02+00:00',
|
||||
'value': 92.287, 'unit': 'm3'},
|
||||
'CHANNEL_ID': 1},
|
||||
{'BELGIUM_MBUS2_DEVICE_TYPE': {'value': 7, 'unit': None},
|
||||
'BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER': {'value': '3853455430303030393631313733',
|
||||
{'MBUS_DEVICE_TYPE': {'value': 7, 'unit': None},
|
||||
'MBUS_EQUIPMENT_IDENTIFIER': {'value': '3853455430303030393631313733',
|
||||
'unit': None},
|
||||
'BELGIUM_MBUS2_METER_READING1': {'datetime': '2023-11-02T11:15:32+00:00',
|
||||
'MBUS_METER_READING': {'datetime': '2023-11-02T11:15:32+00:00',
|
||||
'value': 8.579, 'unit': 'm3'},
|
||||
'CHANNEL_ID': 2}],
|
||||
'BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER': {'value': '37464C4F32313233303838303237', 'unit': None},
|
||||
'BELGIUM_MBUS1_VALVE_POSITION': {'value': 1, 'unit': None},
|
||||
'BELGIUM_MBUS1_METER_READING2': {'datetime': '2023-11-02T11:10:02+00:00', 'value': 92.287, 'unit': 'm3'},
|
||||
'BELGIUM_MBUS2_DEVICE_TYPE': {'value': 7, 'unit': None},
|
||||
'BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER': {'value': '3853455430303030393631313733', 'unit': None},
|
||||
'BELGIUM_MBUS2_METER_READING1': {'datetime': '2023-11-02T11:15:32+00:00', 'value': 8.579, 'unit': 'm3'}}
|
||||
'CHANNEL_ID': 2}]}
|
||||
)
|
||||
|
||||
def test_to_str(self):
|
||||
@ -399,21 +400,14 @@ class TelegramParserFluviusTest(unittest.TestCase):
|
||||
'ACTUAL_TRESHOLD_ELECTRICITY: 999.9 [kW]\n'
|
||||
'FUSE_THRESHOLD_L1: 999 [A]\n'
|
||||
'TEXT_MESSAGE: None [None]\n'
|
||||
'BELGIUM_MBUS1_DEVICE_TYPE: 3 [None]\n'
|
||||
'MBUS DEVICE (channel 1)\n'
|
||||
' BELGIUM_MBUS1_DEVICE_TYPE: 3 [None]\n'
|
||||
' BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER: 37464C4F32313233303838303237 [None]\n'
|
||||
' BELGIUM_MBUS1_VALVE_POSITION: 1 [None]\n'
|
||||
' BELGIUM_MBUS1_METER_READING2: 92.287 [m3] at 2023-11-02T11:10:02+00:00\n'
|
||||
' MBUS_DEVICE_TYPE: 3 [None]\n'
|
||||
' MBUS_EQUIPMENT_IDENTIFIER: 37464C4F32313233303838303237 [None]\n'
|
||||
' MBUS_VALVE_POSITION: 1 [None]\n'
|
||||
' MBUS_METER_READING: 92.287 [m3] at 2023-11-02T11:10:02+00:00\n'
|
||||
'MBUS DEVICE (channel 2)\n'
|
||||
' BELGIUM_MBUS2_DEVICE_TYPE: 7 [None]\n'
|
||||
' BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER: 3853455430303030393631313733 [None]\n'
|
||||
' BELGIUM_MBUS2_METER_READING1: 8.579 [m3] at 2023-11-02T11:15:32+00:00\n'
|
||||
'BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER: 37464C4F32313233303838303237 [None]\n'
|
||||
'BELGIUM_MBUS1_VALVE_POSITION: 1 [None]\n'
|
||||
'BELGIUM_MBUS1_METER_READING2: 92.287 [m3] at 2023-11-02T11:10:02+00:00\n'
|
||||
'BELGIUM_MBUS2_DEVICE_TYPE: 7 [None]\n'
|
||||
'BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER: 3853455430303030393631313733 [None]\n'
|
||||
'BELGIUM_MBUS2_METER_READING1: 8.579 [m3] at 2023-11-02T11:15:32+00:00\n'
|
||||
' MBUS_DEVICE_TYPE: 7 [None]\n'
|
||||
' MBUS_EQUIPMENT_IDENTIFIER: 3853455430303030393631313733 [None]\n'
|
||||
' MBUS_METER_READING: 8.579 [m3] at 2023-11-02T11:15:32+00:00\n'
|
||||
)
|
||||
)
|
||||
|
@ -172,12 +172,6 @@ class TelegramParserV5Test(unittest.TestCase):
|
||||
assert telegram.TEXT_MESSAGE.unit is None
|
||||
assert telegram.TEXT_MESSAGE.value is None
|
||||
|
||||
# DEVICE_TYPE (0-x:24.1.0)
|
||||
assert isinstance(telegram.DEVICE_TYPE, CosemObject)
|
||||
assert telegram.DEVICE_TYPE.unit is None
|
||||
assert isinstance(telegram.DEVICE_TYPE.value, int)
|
||||
assert telegram.DEVICE_TYPE.value == 3
|
||||
|
||||
# INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE (1-0:21.7.0)
|
||||
assert isinstance(telegram.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE, CosemObject)
|
||||
assert telegram.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE.unit == 'kW'
|
||||
@ -215,27 +209,27 @@ class TelegramParserV5Test(unittest.TestCase):
|
||||
assert telegram.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE.value == Decimal('0')
|
||||
|
||||
# There's only one Mbus device (gas meter) in this case. Alternatively
|
||||
# use get_mbget_mbus_device_by_channel
|
||||
# use get_mbus_device_by_channel
|
||||
gas_meter_devices = telegram.MBUS_DEVICES
|
||||
gas_meter_device = gas_meter_devices[0]
|
||||
|
||||
# EQUIPMENT_IDENTIFIER_GAS (0-x:96.1.0)
|
||||
assert isinstance(gas_meter_device.DEVICE_TYPE, CosemObject)
|
||||
assert gas_meter_device.DEVICE_TYPE.unit is None
|
||||
assert isinstance(gas_meter_device.DEVICE_TYPE.value, int)
|
||||
assert gas_meter_device.DEVICE_TYPE.value == 3
|
||||
# MBUS_DEVICE_TYPE (0-1:96.1.0)
|
||||
assert isinstance(gas_meter_device.MBUS_DEVICE_TYPE, CosemObject)
|
||||
assert gas_meter_device.MBUS_DEVICE_TYPE.unit is None
|
||||
assert isinstance(gas_meter_device.MBUS_DEVICE_TYPE.value, int)
|
||||
assert gas_meter_device.MBUS_DEVICE_TYPE.value == 3
|
||||
|
||||
# EQUIPMENT_IDENTIFIER_GAS (0-x:96.1.0)
|
||||
assert isinstance(gas_meter_device.EQUIPMENT_IDENTIFIER_GAS, CosemObject)
|
||||
assert gas_meter_device.EQUIPMENT_IDENTIFIER_GAS.unit is None
|
||||
assert isinstance(gas_meter_device.EQUIPMENT_IDENTIFIER_GAS.value, str)
|
||||
assert gas_meter_device.EQUIPMENT_IDENTIFIER_GAS.value == '3232323241424344313233343536373839'
|
||||
# MBUS_EQUIPMENT_IDENTIFIER (0-1:96.1.0)
|
||||
assert isinstance(gas_meter_device.MBUS_EQUIPMENT_IDENTIFIER, CosemObject)
|
||||
assert gas_meter_device.MBUS_EQUIPMENT_IDENTIFIER.unit is None
|
||||
assert isinstance(gas_meter_device.MBUS_EQUIPMENT_IDENTIFIER.value, str)
|
||||
assert gas_meter_device.MBUS_EQUIPMENT_IDENTIFIER.value == '3232323241424344313233343536373839'
|
||||
|
||||
# HOURLY_GAS_METER_READING (0-1:24.2.1)
|
||||
assert isinstance(gas_meter_device.HOURLY_GAS_METER_READING, MBusObject)
|
||||
assert gas_meter_device.HOURLY_GAS_METER_READING.unit == 'm3'
|
||||
assert isinstance(telegram.HOURLY_GAS_METER_READING.value, Decimal)
|
||||
assert gas_meter_device.HOURLY_GAS_METER_READING.value == Decimal('0.107')
|
||||
# MBUS_METER_READING (0-1:24.2.1)
|
||||
assert isinstance(gas_meter_device.MBUS_METER_READING, MBusObject)
|
||||
assert gas_meter_device.MBUS_METER_READING.unit == 'm3'
|
||||
assert isinstance(telegram.MBUS_METER_READING.value, Decimal)
|
||||
assert gas_meter_device.MBUS_METER_READING.value == Decimal('0.107')
|
||||
|
||||
def test_checksum_valid(self):
|
||||
# No exception is raised.
|
||||
@ -270,8 +264,11 @@ class TelegramParserV5Test(unittest.TestCase):
|
||||
parser = TelegramParser(telegram_specifications.V5)
|
||||
telegram = parser.parse(invalid_date_telegram)
|
||||
|
||||
# HOURLY_GAS_METER_READING (0-1:24.2.1)
|
||||
assert isinstance(telegram.HOURLY_GAS_METER_READING, MBusObject)
|
||||
assert telegram.HOURLY_GAS_METER_READING.unit is None
|
||||
assert isinstance(telegram.HOURLY_GAS_METER_READING.value, Decimal)
|
||||
assert telegram.HOURLY_GAS_METER_READING.value == Decimal('0.000')
|
||||
# MBUS DEVICE 1
|
||||
mbus1 = telegram.get_mbus_device_by_channel(1)
|
||||
|
||||
# MBUS_METER_READING (0-1:24.2.1)
|
||||
assert isinstance(mbus1.MBUS_METER_READING, MBusObject)
|
||||
assert mbus1.MBUS_METER_READING.unit is None
|
||||
assert isinstance(mbus1.MBUS_METER_READING.value, Decimal)
|
||||
assert mbus1.MBUS_METER_READING.value == Decimal('0.000')
|
||||
|
Loading…
Reference in New Issue
Block a user