Change default V5 to mbus

At least the BE and the NL DSMR devices use MBUS.
Therefor we make the MBUS obis reference generic, and convert the V5
telegram to use MBUS values.

Also remove BELGIUM_MAX_POWER_PER_PHASE as this was a duplicate.

Finally set self.maxDiff = None to have a full test output on some
tests.
This commit is contained in:
Jean-Louis Dupond 2023-10-25 10:38:38 +02:00
parent 5810770b74
commit 9c679bafe2
6 changed files with 334 additions and 220 deletions

View File

@ -69,8 +69,48 @@ ACTUAL_TRESHOLD_ELECTRICITY = r'^\d-\d:17\.0\.0.+?\r\n'
ACTUAL_SWITCH_POSITION = r'^\d-\d:96\.3\.10.+?\r\n' ACTUAL_SWITCH_POSITION = r'^\d-\d:96\.3\.10.+?\r\n'
VALVE_POSITION_GAS = r'^\d-\d:24\.4\.0.+?\r\n' VALVE_POSITION_GAS = r'^\d-\d:24\.4\.0.+?\r\n'
# Multiple 'slaves' can be linked to the main device.
# The type is reported on 24.1.0
# Specifications are in EN 13757-3
# For example: Water mater = 7, Gas meter = 3
# Identifier is on 96.1.0 (in NL for ex) or
# on 96.1.1 (in BE for ex)
# The values are reported on 24.2.1
# With an exception in Belgium for the GAS meter
# Be aware that for the gas volume, another OBIS-code is published
# than the one listed in section 7 of DSMR P1.
# This is due to the fact that in Belgium the not-temperature
# corrected gas volume is used while in the Netherlands,
# the temperature corrected gas volume is used.
MBUS1_DEVICE_TYPE = r'^\d-1:24\.1\.0.+?\r\n'
MBUS1_EQUIPMENT_IDENTIFIER = r'^\d-1:96\.1\.0.+?\r\n'
MBUS1_EQUIPMENT_IDENTIFIER_ALT = r'^\d-1:96\.1\.1.+?\r\n'
MBUS1_VALVE_POSITION = r'^\d-1:24\.4\.0.+?\r\n'
MBUS1_METER_READING = r'^\d-1:24\.2\.1.+?\r\n'
MBUS1_METER_READING_ALT = r'^\d-1:24\.2\.3.+?\r\n'
MBUS2_DEVICE_TYPE = r'^\d-2:24\.1\.0.+?\r\n'
MBUS2_EQUIPMENT_IDENTIFIER = r'^\d-2:96\.1\.0.+?\r\n'
MBUS2_EQUIPMENT_IDENTIFIER_ALT = r'^\d-2:96\.1\.1.+?\r\n'
MBUS2_VALVE_POSITION = r'^\d-2:24\.4\.0.+?\r\n'
MBUS2_METER_READING = r'^\d-2:24\.2\.1.+?\r\n'
MBUS2_METER_READING_ALT = r'^\d-2:24\.2\.3.+?\r\n'
MBUS3_DEVICE_TYPE = r'^\d-3:24\.1\.0.+?\r\n'
MBUS3_EQUIPMENT_IDENTIFIER = r'^\d-3:96\.1\.0.+?\r\n'
MBUS3_EQUIPMENT_IDENTIFIER_ALT = r'^\d-3:96\.1\.1.+?\r\n'
MBUS3_VALVE_POSITION = r'^\d-3:24\.4\.0.+?\r\n'
MBUS3_METER_READING = r'^\d-3:24\.2\.1.+?\r\n'
MBUS3_METER_READING_ALT = r'^\d-3:24\.2\.3.+?\r\n'
MBUS4_DEVICE_TYPE = r'^\d-4:24\.1\.0.+?\r\n'
MBUS4_EQUIPMENT_IDENTIFIER = r'^\d-4:96\.1\.0.+?\r\n'
MBUS4_EQUIPMENT_IDENTIFIER_ALT = r'^\d-4:96\.1\.1.+?\r\n'
MBUS4_VALVE_POSITION = r'^\d-4:24\.4\.0.+?\r\n'
MBUS4_METER_READING = r'^\d-4:24\.2\.1.+?\r\n'
MBUS4_METER_READING_ALT = r'^\d-4:24\.2\.3.+?\r\n'
# TODO 17.0.0 # TODO 17.0.0
# TODO 96.3.10
ELECTRICITY_USED_TARIFF_ALL = ( ELECTRICITY_USED_TARIFF_ALL = (
ELECTRICITY_USED_TARIFF_1, ELECTRICITY_USED_TARIFF_1,
@ -91,37 +131,6 @@ BELGIUM_EQUIPMENT_IDENTIFIER = r'^\d-0:96\.1\.1.+?\r\n'
BELGIUM_CURRENT_AVERAGE_DEMAND = r'^\d-\d:1\.4\.0.+?\r\n' BELGIUM_CURRENT_AVERAGE_DEMAND = r'^\d-\d:1\.4\.0.+?\r\n'
BELGIUM_MAXIMUM_DEMAND_MONTH = r'^\d-\d:1\.6\.0.+?\r\n' BELGIUM_MAXIMUM_DEMAND_MONTH = r'^\d-\d:1\.6\.0.+?\r\n'
BELGIUM_MAXIMUM_DEMAND_13_MONTHS = r'^\d-\d:98\.1\.0.+?\r\n' BELGIUM_MAXIMUM_DEMAND_13_MONTHS = r'^\d-\d:98\.1\.0.+?\r\n'
BELGIUM_MAX_POWER_PER_PHASE = r'^\d-\d:17\.0\.0.+?\r\n' # Applicable when power limitation is active
# Multiple 'slaves' can be linked to the main device.
# Mostly MBUS1 = GAS METER with values on 24.2.3
# While WATER METER reports it's values on 24.2.1
# The GAS METER also reports its valve state on 24.4.0
# Dev type for gas = 7 and water = 8
BELGIUM_MBUS1_DEVICE_TYPE = r'^\d-1:24\.1\.0.+?\r\n'
BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER = r'^\d-1:96\.1\.1.+?\r\n'
BELGIUM_MBUS1_VALVE_POSITION = r'^\d-1:24\.4\.0.+?\r\n'
BELGIUM_MBUS1_METER_READING1 = r'^\d-1:24\.2\.1.+?\r\n'
BELGIUM_MBUS1_METER_READING2 = r'^\d-1:24\.2\.3.+?\r\n'
BELGIUM_MBUS2_DEVICE_TYPE = r'^\d-2:24\.1\.0.+?\r\n'
BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER = r'^\d-2:96\.1\.1.+?\r\n'
BELGIUM_MBUS2_VALVE_POSITION = r'^\d-2:24\.4\.0.+?\r\n'
BELGIUM_MBUS2_METER_READING1 = r'^\d-2:24\.2\.1.+?\r\n'
BELGIUM_MBUS2_METER_READING2 = r'^\d-2:24\.2\.3.+?\r\n'
BELGIUM_MBUS3_DEVICE_TYPE = r'^\d-3:24\.1\.0.+?\r\n'
BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER = r'^\d-3:96\.1\.1.+?\r\n'
BELGIUM_MBUS3_VALVE_POSITION = r'^\d-3:24\.4\.0.+?\r\n'
BELGIUM_MBUS3_METER_READING1 = r'^\d-3:24\.2\.1.+?\r\n'
BELGIUM_MBUS3_METER_READING2 = r'^\d-3:24\.2\.3.+?\r\n'
BELGIUM_MBUS4_DEVICE_TYPE = r'^\d-4:24\.1\.0.+?\r\n'
BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER = r'^\d-4:96\.1\.1.+?\r\n'
BELGIUM_MBUS4_VALVE_POSITION = r'^\d-4:24\.4\.0.+?\r\n'
BELGIUM_MBUS4_METER_READING1 = r'^\d-4:24\.2\.1.+?\r\n'
BELGIUM_MBUS4_METER_READING2 = r'^\d-4:24\.2\.3.+?\r\n'
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'^\d-\d:42\.0\.0.+?\r\n' # Logical device name LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'^\d-\d:42\.0\.0.+?\r\n' # Logical device name

View File

@ -430,11 +430,6 @@ V5 = {
'value_parser': CosemParser(ValueParser(str)), 'value_parser': CosemParser(ValueParser(str)),
'value_name': 'TEXT_MESSAGE' 'value_name': 'TEXT_MESSAGE'
}, },
{
'obis_reference': obis.DEVICE_TYPE,
'value_parser': CosemParser(ValueParser(int)),
'value_name': 'DEVICE_TYPE'
},
{ {
'obis_reference': obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE, 'obis_reference': obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE,
'value_parser': CosemParser(ValueParser(Decimal)), 'value_parser': CosemParser(ValueParser(Decimal)),
@ -466,17 +461,128 @@ V5 = {
'value_name': 'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE' 'value_name': 'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE'
}, },
{ {
'obis_reference': obis.EQUIPMENT_IDENTIFIER_GAS, 'obis_reference': obis.MBUS1_DEVICE_TYPE,
'value_parser': CosemParser(ValueParser(str)), 'value_parser': CosemParser(ValueParser(int)),
'value_name': 'EQUIPMENT_IDENTIFIER_GAS' 'value_name': 'MBUS1_DEVICE_TYPE'
}, },
{ {
'obis_reference': obis.HOURLY_GAS_METER_READING, 'obis_reference': obis.MBUS1_EQUIPMENT_IDENTIFIER,
'value_parser': MBusParser( 'value_parser': CosemParser(ValueParser(str)),
'value_name': 'MBUS1_EQUIPMENT_IDENTIFIER'
},
{
'obis_reference': obis.MBUS1_VALVE_POSITION,
'value_parser': CosemParser(ValueParser(int)),
'value_name': 'MBUS1_VALVE_POSITION'
},
{
'obis_reference': obis.MBUS1_METER_READING,
'value_parser': MBusParser(
ValueParser(timestamp), ValueParser(timestamp),
ValueParser(Decimal) ValueParser(Decimal)
), ),
'value_name': 'HOURLY_GAS_METER_READING' 'value_name': 'MBUS1_METER_READING'
},
{
'obis_reference': obis.MBUS1_METER_READING_ALT,
'value_parser': MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
'value_name': 'MBUS1_METER_READING_ALT'
},
{
'obis_reference': obis.MBUS2_DEVICE_TYPE,
'value_parser': CosemParser(ValueParser(int)),
'value_name': 'MBUS2_DEVICE_TYPE'
},
{
'obis_reference': obis.MBUS2_EQUIPMENT_IDENTIFIER,
'value_parser': CosemParser(ValueParser(str)),
'value_name': 'MBUS2_EQUIPMENT_IDENTIFIER'
},
{
'obis_reference': obis.MBUS2_VALVE_POSITION,
'value_parser': CosemParser(ValueParser(int)),
'value_name': 'MBUS2_VALVE_POSITION'
},
{
'obis_reference': obis.MBUS2_METER_READING,
'value_parser': MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
'value_name': 'MBUS2_METER_READING'
},
{
'obis_reference': obis.MBUS2_METER_READING_ALT,
'value_parser': MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
'value_name': 'MBUS2_METER_READING_ALT'
},
{
'obis_reference': obis.MBUS3_DEVICE_TYPE,
'value_parser': CosemParser(ValueParser(int)),
'value_name': 'MBUS3_DEVICE_TYPE'
},
{
'obis_reference': obis.MBUS3_EQUIPMENT_IDENTIFIER,
'value_parser': CosemParser(ValueParser(str)),
'value_name': 'MBUS3_EQUIPMENT_IDENTIFIER'
},
{
'obis_reference': obis.MBUS3_VALVE_POSITION,
'value_parser': CosemParser(ValueParser(int)),
'value_name': 'MBUS3_VALVE_POSITION'
},
{
'obis_reference': obis.MBUS3_METER_READING,
'value_parser': MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
'value_name': 'MBUS3_METER_READING'
},
{
'obis_reference': obis.MBUS3_METER_READING_ALT,
'value_parser': MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
'value_name': 'MBUS3_METER_READING_ALT'
},
{
'obis_reference': obis.MBUS4_DEVICE_TYPE,
'value_parser': CosemParser(ValueParser(int)),
'value_name': 'MBUS4_DEVICE_TYPE'
},
{
'obis_reference': obis.MBUS4_EQUIPMENT_IDENTIFIER,
'value_parser': CosemParser(ValueParser(str)),
'value_name': 'MBUS4_EQUIPMENT_IDENTIFIER'
},
{
'obis_reference': obis.MBUS4_VALVE_POSITION,
'value_parser': CosemParser(ValueParser(int)),
'value_name': 'MBUS4_VALVE_POSITION'
},
{
'obis_reference': obis.MBUS4_METER_READING,
'value_parser': MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
'value_name': 'MBUS4_METER_READING'
},
{
'obis_reference': obis.MBUS4_METER_READING_ALT,
'value_parser': MBusParser(
ValueParser(timestamp),
ValueParser(Decimal)
),
'value_name': 'MBUS4_METER_READING_ALT'
}, },
] ]
} }
@ -624,11 +730,6 @@ BELGIUM_FLUVIUS = {
'value_parser': CosemParser(ValueParser(Decimal)), 'value_parser': CosemParser(ValueParser(Decimal)),
'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY' 'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY'
}, },
{
'obis_reference': obis.BELGIUM_MAX_POWER_PER_PHASE,
'value_parser': CosemParser(ValueParser(Decimal)),
'value_name': 'BELGIUM_MAX_POWER_PER_PHASE'
},
{ {
'obis_reference': obis.FUSE_THRESHOLD_L1, 'obis_reference': obis.FUSE_THRESHOLD_L1,
'value_parser': CosemParser(ValueParser(Decimal)), 'value_parser': CosemParser(ValueParser(Decimal)),
@ -640,128 +741,128 @@ BELGIUM_FLUVIUS = {
'value_name': 'TEXT_MESSAGE' 'value_name': 'TEXT_MESSAGE'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS1_DEVICE_TYPE, 'obis_reference': obis.MBUS1_DEVICE_TYPE,
'value_parser': CosemParser(ValueParser(int)), 'value_parser': CosemParser(ValueParser(int)),
'value_name': 'BELGIUM_MBUS1_DEVICE_TYPE' 'value_name': 'MBUS1_DEVICE_TYPE'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER, 'obis_reference': obis.MBUS1_EQUIPMENT_IDENTIFIER_ALT,
'value_parser': CosemParser(ValueParser(str)), 'value_parser': CosemParser(ValueParser(str)),
'value_name': 'BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER' 'value_name': 'MBUS1_EQUIPMENT_IDENTIFIER_ALT'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS1_VALVE_POSITION, 'obis_reference': obis.MBUS1_VALVE_POSITION,
'value_parser': CosemParser(ValueParser(int)), 'value_parser': CosemParser(ValueParser(int)),
'value_name': 'BELGIUM_MBUS1_VALVE_POSITION' 'value_name': 'MBUS1_VALVE_POSITION'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS1_METER_READING1, 'obis_reference': obis.MBUS1_METER_READING,
'value_parser': MBusParser( 'value_parser': MBusParser(
ValueParser(timestamp), ValueParser(timestamp),
ValueParser(Decimal) ValueParser(Decimal)
), ),
'value_name': 'BELGIUM_MBUS1_METER_READING1' 'value_name': 'MBUS1_METER_READING'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS1_METER_READING2, 'obis_reference': obis.MBUS1_METER_READING_ALT,
'value_parser': MBusParser( 'value_parser': MBusParser(
ValueParser(timestamp), ValueParser(timestamp),
ValueParser(Decimal) ValueParser(Decimal)
), ),
'value_name': 'BELGIUM_MBUS1_METER_READING2' 'value_name': 'MBUS1_METER_READING_ALT'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS2_DEVICE_TYPE, 'obis_reference': obis.MBUS2_DEVICE_TYPE,
'value_parser': CosemParser(ValueParser(int)), 'value_parser': CosemParser(ValueParser(int)),
'value_name': 'BELGIUM_MBUS2_DEVICE_TYPE' 'value_name': 'MBUS2_DEVICE_TYPE'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER, 'obis_reference': obis.MBUS2_EQUIPMENT_IDENTIFIER_ALT,
'value_parser': CosemParser(ValueParser(str)), 'value_parser': CosemParser(ValueParser(str)),
'value_name': 'BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER' 'value_name': 'MBUS2_EQUIPMENT_IDENTIFIER_ALT'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS2_VALVE_POSITION, 'obis_reference': obis.MBUS2_VALVE_POSITION,
'value_parser': CosemParser(ValueParser(int)), 'value_parser': CosemParser(ValueParser(int)),
'value_name': 'BELGIUM_MBUS2_VALVE_POSITION' 'value_name': 'MBUS2_VALVE_POSITION'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS2_METER_READING1, 'obis_reference': obis.MBUS2_METER_READING,
'value_parser': MBusParser( 'value_parser': MBusParser(
ValueParser(timestamp), ValueParser(timestamp),
ValueParser(Decimal) ValueParser(Decimal)
), ),
'value_name': 'BELGIUM_MBUS2_METER_READING1' 'value_name': 'MBUS2_METER_READING'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS2_METER_READING2, 'obis_reference': obis.MBUS2_METER_READING_ALT,
'value_parser': MBusParser( 'value_parser': MBusParser(
ValueParser(timestamp), ValueParser(timestamp),
ValueParser(Decimal) ValueParser(Decimal)
), ),
'value_name': 'BELGIUM_MBUS2_METER_READING2' 'value_name': 'MBUS2_METER_READING_ALT'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS3_DEVICE_TYPE, 'obis_reference': obis.MBUS3_DEVICE_TYPE,
'value_parser': CosemParser(ValueParser(int)), 'value_parser': CosemParser(ValueParser(int)),
'value_name': 'BELGIUM_MBUS3_DEVICE_TYPE' 'value_name': 'MBUS3_DEVICE_TYPE'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER, 'obis_reference': obis.MBUS3_EQUIPMENT_IDENTIFIER_ALT,
'value_parser': CosemParser(ValueParser(str)), 'value_parser': CosemParser(ValueParser(str)),
'value_name': 'BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER' 'value_name': 'MBUS3_EQUIPMENT_IDENTIFIER_ALT'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS3_VALVE_POSITION, 'obis_reference': obis.MBUS3_VALVE_POSITION,
'value_parser': CosemParser(ValueParser(int)), 'value_parser': CosemParser(ValueParser(int)),
'value_name': 'BELGIUM_MBUS3_VALVE_POSITION' 'value_name': 'MBUS3_VALVE_POSITION'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS3_METER_READING1, 'obis_reference': obis.MBUS3_METER_READING,
'value_parser': MBusParser( 'value_parser': MBusParser(
ValueParser(timestamp), ValueParser(timestamp),
ValueParser(Decimal) ValueParser(Decimal)
), ),
'value_name': 'BELGIUM_MBUS3_METER_READING1' 'value_name': 'MBUS3_METER_READING'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS3_METER_READING2, 'obis_reference': obis.MBUS3_METER_READING_ALT,
'value_parser': MBusParser( 'value_parser': MBusParser(
ValueParser(timestamp), ValueParser(timestamp),
ValueParser(Decimal) ValueParser(Decimal)
), ),
'value_name': 'BELGIUM_MBUS3_METER_READING2' 'value_name': 'MBUS3_METER_READING_ALT'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS4_DEVICE_TYPE, 'obis_reference': obis.MBUS4_DEVICE_TYPE,
'value_parser': CosemParser(ValueParser(int)), 'value_parser': CosemParser(ValueParser(int)),
'value_name': 'BELGIUM_MBUS4_DEVICE_TYPE' 'value_name': 'MBUS4_DEVICE_TYPE'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER, 'obis_reference': obis.MBUS4_EQUIPMENT_IDENTIFIER_ALT,
'value_parser': CosemParser(ValueParser(str)), 'value_parser': CosemParser(ValueParser(str)),
'value_name': 'BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER' 'value_name': 'MBUS4_EQUIPMENT_IDENTIFIER_ALT'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS4_VALVE_POSITION, 'obis_reference': obis.MBUS4_VALVE_POSITION,
'value_parser': CosemParser(ValueParser(int)), 'value_parser': CosemParser(ValueParser(int)),
'value_name': 'BELGIUM_MBUS4_VALVE_POSITION' 'value_name': 'MBUS4_VALVE_POSITION'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS4_METER_READING1, 'obis_reference': obis.MBUS4_METER_READING,
'value_parser': MBusParser( 'value_parser': MBusParser(
ValueParser(timestamp), ValueParser(timestamp),
ValueParser(Decimal) ValueParser(Decimal)
), ),
'value_name': 'BELGIUM_MBUS4_METER_READING1' 'value_name': 'MBUS4_METER_READING'
}, },
{ {
'obis_reference': obis.BELGIUM_MBUS4_METER_READING2, 'obis_reference': obis.MBUS4_METER_READING_ALT,
'value_parser': MBusParser( 'value_parser': MBusParser(
ValueParser(timestamp), ValueParser(timestamp),
ValueParser(Decimal) ValueParser(Decimal)
), ),
'value_name': 'BELGIUM_MBUS4_METER_READING2' 'value_name': 'MBUS4_METER_READING_ALT'
}, },
] ]
} }
@ -1233,7 +1334,7 @@ EON_HUNGARY = {
# This seems to be wrong in documentation, it's not 0-0:96.50.68, but 0-0:96.3.10 # This seems to be wrong in documentation, it's not 0-0:96.50.68, but 0-0:96.3.10
}, },
{ {
'obis_reference': obis.BELGIUM_MAX_POWER_PER_PHASE, 'obis_reference': obis.ACTUAL_TRESHOLD_ELECTRICITY,
'value_parser': CosemParser(ValueParser(Decimal)), 'value_parser': CosemParser(ValueParser(Decimal)),
'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY' 'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY'
}, },

View File

@ -15,59 +15,59 @@ class MbusDeviceTest(unittest.TestCase):
device_type_parser = [ device_type_parser = [
object["value_parser"] object["value_parser"]
for object in v5_objects for object in v5_objects
if object["obis_reference"] == obis_references.DEVICE_TYPE if object["obis_reference"] == obis_references.MBUS2_DEVICE_TYPE
][0] ][0]
device_type = device_type_parser.parse('0-2:24.1.0(003)\r\n') device_type = device_type_parser.parse('0-2:24.1.0(003)\r\n')
equipment_parser = [ equipment_parser = [
object["value_parser"] object["value_parser"]
for object in v5_objects for object in v5_objects
if object["obis_reference"] == obis_references.EQUIPMENT_IDENTIFIER_GAS if object["obis_reference"] == obis_references.MBUS2_EQUIPMENT_IDENTIFIER
][0] ][0]
equipment = equipment_parser.parse('0-2:96.1.0(4730303339303031393336393930363139)\r\n') equipment = equipment_parser.parse('0-2:96.1.0(4730303339303031393336393930363139)\r\n')
gas_reading_parser = [ gas_reading_parser = [
object["value_parser"] object["value_parser"]
for object in v5_objects for object in v5_objects
if object["obis_reference"] == obis_references.HOURLY_GAS_METER_READING if object["obis_reference"] == obis_references.MBUS2_METER_READING
][0] ][0]
gas_reading = gas_reading_parser.parse('0-2:24.2.1(200426223001S)(00246.138*m3)\r\n') gas_reading = gas_reading_parser.parse('0-2:24.2.1(200426223001S)(00246.138*m3)\r\n')
mbus_device = MbusDevice(channel_id=1) mbus_device = MbusDevice(channel_id=2)
mbus_device.add(obis_references.DEVICE_TYPE, device_type, "DEVICE_TYPE") mbus_device.add(obis_references.MBUS2_DEVICE_TYPE, device_type, "MBUS2_DEVICE_TYPE")
mbus_device.add(obis_references.EQUIPMENT_IDENTIFIER_GAS, equipment, "EQUIPMENT_IDENTIFIER_GAS") mbus_device.add(obis_references.MBUS2_EQUIPMENT_IDENTIFIER, equipment, "MBUS2_EQUIPMENT_IDENTIFIER")
mbus_device.add(obis_references.HOURLY_GAS_METER_READING, gas_reading, "HOURLY_GAS_METER_READING") mbus_device.add(obis_references.MBUS2_METER_READING, gas_reading, "MBUS2_METER_READING")
self.mbus_device = mbus_device self.mbus_device = mbus_device
def test_attributes(self): def test_attributes(self):
self.assertEqual(self.mbus_device.DEVICE_TYPE.value, 3) self.assertEqual(self.mbus_device.MBUS2_DEVICE_TYPE.value, 3)
self.assertEqual(self.mbus_device.DEVICE_TYPE.unit, None) self.assertEqual(self.mbus_device.MBUS2_DEVICE_TYPE.unit, None)
self.assertEqual(self.mbus_device.EQUIPMENT_IDENTIFIER_GAS.value, self.assertEqual(self.mbus_device.MBUS2_EQUIPMENT_IDENTIFIER.value,
'4730303339303031393336393930363139') '4730303339303031393336393930363139')
self.assertEqual(self.mbus_device.EQUIPMENT_IDENTIFIER_GAS.unit, None) self.assertEqual(self.mbus_device.MBUS2_EQUIPMENT_IDENTIFIER.unit, None)
self.assertEqual(self.mbus_device.HOURLY_GAS_METER_READING.value, Decimal('246.138')) self.assertEqual(self.mbus_device.MBUS2_METER_READING.value, Decimal('246.138'))
self.assertEqual(self.mbus_device.HOURLY_GAS_METER_READING.unit, 'm3') self.assertEqual(self.mbus_device.MBUS2_METER_READING.unit, 'm3')
def test_to_json(self): def test_to_json(self):
self.assertEqual( self.assertEqual(
json.loads(self.mbus_device.to_json()), json.loads(self.mbus_device.to_json()),
{ {
'CHANNEL_ID': 1, 'CHANNEL_ID': 2,
'DEVICE_TYPE': {'value': 3, 'unit': None}, 'MBUS2_DEVICE_TYPE': {'value': 3, 'unit': None},
'EQUIPMENT_IDENTIFIER_GAS': {'value': '4730303339303031393336393930363139', 'unit': None}, 'MBUS2_EQUIPMENT_IDENTIFIER': {'value': '4730303339303031393336393930363139', 'unit': None},
'HOURLY_GAS_METER_READING': {'datetime': '2020-04-26T20:30:01+00:00', 'value': 246.138, 'unit': 'm3'}} 'MBUS2_METER_READING': {'datetime': '2020-04-26T20:30:01+00:00', 'value': 246.138, 'unit': 'm3'}}
) )
def test_str(self): def test_str(self):
self.assertEqual( self.assertEqual(
str(self.mbus_device), str(self.mbus_device),
( (
'MBUS DEVICE (channel 1)\n' 'MBUS DEVICE (channel 2)\n'
'\tDEVICE_TYPE: 3 [None]\n' '\tMBUS2_DEVICE_TYPE: 3 [None]\n'
'\tEQUIPMENT_IDENTIFIER_GAS: 4730303339303031393336393930363139 [None]\n' '\tMBUS2_EQUIPMENT_IDENTIFIER: 4730303339303031393336393930363139 [None]\n'
'\tHOURLY_GAS_METER_READING: 246.138 [m3] at 2020-04-26T20:30:01+00:00\n' '\tMBUS2_METER_READING: 246.138 [m3] at 2020-04-26T20:30:01+00:00\n'
) )
) )

View File

@ -216,14 +216,6 @@ class TelegramTest(unittest.TestCase):
value_type=Decimal, value_type=Decimal,
value_val=Decimal('2')) value_val=Decimal('2'))
# DEVICE_TYPE (0-x:24.1.0)
self.verify_telegram_item(telegram,
'DEVICE_TYPE',
object_type=CosemObject,
unit_val=None,
value_type=int,
value_val=3)
# INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE (1-0:21.7.0) # INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE (1-0:21.7.0)
self.verify_telegram_item(telegram, self.verify_telegram_item(telegram,
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE', 'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE',
@ -272,7 +264,15 @@ class TelegramTest(unittest.TestCase):
value_type=Decimal, value_type=Decimal,
value_val=Decimal('0')) value_val=Decimal('0'))
# EQUIPMENT_IDENTIFIER_GAS (0-x:96.1.0) # DEVICE_TYPE (0-1:24.1.0)
self.verify_telegram_item(telegram,
'DEVICE_TYPE',
object_type=CosemObject,
unit_val=None,
value_type=int,
value_val=3)
# EQUIPMENT_IDENTIFIER_GAS (0-1:96.1.0)
self.verify_telegram_item(telegram, self.verify_telegram_item(telegram,
'EQUIPMENT_IDENTIFIER_GAS', 'EQUIPMENT_IDENTIFIER_GAS',
object_type=CosemObject, object_type=CosemObject,
@ -340,28 +340,28 @@ class TelegramTest(unittest.TestCase):
self.assertEqual(len(mbus_devices), 2) self.assertEqual(len(mbus_devices), 2)
mbus_device_1 = mbus_devices[0] mbus_device_1 = mbus_devices[0]
self.assertEqual(mbus_device_1.DEVICE_TYPE.value, 3) self.assertEqual(mbus_device_1.MBUS1_DEVICE_TYPE.value, 3)
self.assertEqual(mbus_device_1.EQUIPMENT_IDENTIFIER_GAS.value, None) self.assertEqual(mbus_device_1.MBUS1_EQUIPMENT_IDENTIFIER.value, None)
self.assertEqual(mbus_device_1.HOURLY_GAS_METER_READING.value, Decimal('0')) self.assertEqual(mbus_device_1.MBUS1_METER_READING.value, Decimal('0'))
mbus_device_2 = mbus_devices[1] mbus_device_2 = mbus_devices[1]
self.assertEqual(mbus_device_2.DEVICE_TYPE.value, 3) self.assertEqual(mbus_device_2.MBUS2_DEVICE_TYPE.value, 3)
self.assertEqual(mbus_device_2.EQUIPMENT_IDENTIFIER_GAS.value, '4730303339303031393336393930363139') self.assertEqual(mbus_device_2.MBUS2_EQUIPMENT_IDENTIFIER.value, '4730303339303031393336393930363139')
self.assertEqual(mbus_device_2.HOURLY_GAS_METER_READING.value, Decimal('246.138')) self.assertEqual(mbus_device_2.MBUS2_METER_READING.value, Decimal('246.138'))
def test_get_mbus_device_by_channel(self): def test_get_mbus_device_by_channel(self):
parser = TelegramParser(telegram_specifications.V5) parser = TelegramParser(telegram_specifications.V5)
telegram = parser.parse(TELEGRAM_V5_TWO_MBUS) telegram = parser.parse(TELEGRAM_V5_TWO_MBUS)
mbus_device_1 = telegram.get_mbus_device_by_channel(1) mbus_device_1 = telegram.get_mbus_device_by_channel(1)
self.assertEqual(mbus_device_1.DEVICE_TYPE.value, 3) self.assertEqual(mbus_device_1.MBUS1_DEVICE_TYPE.value, 3)
self.assertEqual(mbus_device_1.EQUIPMENT_IDENTIFIER_GAS.value, None) self.assertEqual(mbus_device_1.MBUS1_EQUIPMENT_IDENTIFIER.value, None)
self.assertEqual(mbus_device_1.HOURLY_GAS_METER_READING.value, Decimal('0')) self.assertEqual(mbus_device_1.MBUS1_METER_READING.value, Decimal('0'))
mbus_device_2 = telegram.get_mbus_device_by_channel(2) mbus_device_2 = telegram.get_mbus_device_by_channel(2)
self.assertEqual(mbus_device_2.DEVICE_TYPE.value, 3) self.assertEqual(mbus_device_2.MBUS2_DEVICE_TYPE.value, 3)
self.assertEqual(mbus_device_2.EQUIPMENT_IDENTIFIER_GAS.value, '4730303339303031393336393930363139') self.assertEqual(mbus_device_2.MBUS2_EQUIPMENT_IDENTIFIER.value, '4730303339303031393336393930363139')
self.assertEqual(mbus_device_2.HOURLY_GAS_METER_READING.value, Decimal('246.138')) self.assertEqual(mbus_device_2.MBUS2_METER_READING.value, Decimal('246.138'))
def test_without_mbus_devices(self): def test_without_mbus_devices(self):
parser = TelegramParser(telegram_specifications.V5, apply_checksum_validation=False) parser = TelegramParser(telegram_specifications.V5, apply_checksum_validation=False)
@ -375,11 +375,12 @@ class TelegramTest(unittest.TestCase):
telegram = parser.parse(TELEGRAM_V5) telegram = parser.parse(TELEGRAM_V5)
json_data = json.loads(telegram.to_json()) json_data = json.loads(telegram.to_json())
self.maxDiff = None
self.assertEqual( self.assertEqual(
json_data, json_data,
{'CURRENT_ELECTRICITY_DELIVERY': {'unit': 'kW', 'value': 0.0}, {'CURRENT_ELECTRICITY_DELIVERY': {'unit': 'kW', 'value': 0.0},
'CURRENT_ELECTRICITY_USAGE': {'unit': 'kW', 'value': 0.244}, 'CURRENT_ELECTRICITY_USAGE': {'unit': 'kW', 'value': 0.244},
'DEVICE_TYPE': {'unit': None, 'value': 3},
'ELECTRICITY_ACTIVE_TARIFF': {'unit': None, 'value': '0002'}, 'ELECTRICITY_ACTIVE_TARIFF': {'unit': None, 'value': '0002'},
'ELECTRICITY_DELIVERED_TARIFF_1': {'unit': 'kWh', 'value': 2.444}, 'ELECTRICITY_DELIVERED_TARIFF_1': {'unit': 'kWh', 'value': 2.444},
'ELECTRICITY_DELIVERED_TARIFF_2': {'unit': 'kWh', 'value': 0.0}, 'ELECTRICITY_DELIVERED_TARIFF_2': {'unit': 'kWh', 'value': 0.0},
@ -387,10 +388,6 @@ class TelegramTest(unittest.TestCase):
'ELECTRICITY_USED_TARIFF_2': {'unit': 'kWh', 'value': 2.399}, 'ELECTRICITY_USED_TARIFF_2': {'unit': 'kWh', 'value': 2.399},
'EQUIPMENT_IDENTIFIER': {'unit': None, 'EQUIPMENT_IDENTIFIER': {'unit': None,
'value': '4B384547303034303436333935353037'}, 'value': '4B384547303034303436333935353037'},
'EQUIPMENT_IDENTIFIER_GAS': {'unit': None, 'value': None},
'HOURLY_GAS_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00',
'unit': 'm3',
'value': 0.107},
'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE': {'unit': 'kW', 'value': 0.0}, 'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE': {'unit': 'kW', 'value': 0.0},
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE': {'unit': 'kW', 'value': 0.07}, 'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE': {'unit': 'kW', 'value': 0.07},
'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE': {'unit': 'kW', 'value': 0.0}, 'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE': {'unit': 'kW', 'value': 0.0},
@ -404,16 +401,25 @@ class TelegramTest(unittest.TestCase):
'INSTANTANEOUS_VOLTAGE_L2': {'unit': 'V', 'value': 230.0}, 'INSTANTANEOUS_VOLTAGE_L2': {'unit': 'V', 'value': 230.0},
'INSTANTANEOUS_VOLTAGE_L3': {'unit': 'V', 'value': 229.0}, 'INSTANTANEOUS_VOLTAGE_L3': {'unit': 'V', 'value': 229.0},
'LONG_POWER_FAILURE_COUNT': {'unit': None, 'value': 0}, 'LONG_POWER_FAILURE_COUNT': {'unit': None, 'value': 0},
'MBUS1_DEVICE_TYPE': {'unit': None, 'value': 3},
'MBUS1_EQUIPMENT_IDENTIFIER': {'unit': None,
'value': '3232323241424344313233343536373839'},
'MBUS1_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00',
'unit': 'm3',
'value': 0.107},
'MBUS2_DEVICE_TYPE': {'unit': None, 'value': 3},
'MBUS2_EQUIPMENT_IDENTIFIER': {'unit': None, 'value': None},
'MBUS_DEVICES': [{'CHANNEL_ID': 1, 'MBUS_DEVICES': [{'CHANNEL_ID': 1,
'DEVICE_TYPE': {'unit': None, 'value': 3}, 'MBUS1_DEVICE_TYPE': {'unit': None, 'value': 3},
'EQUIPMENT_IDENTIFIER_GAS': {'unit': None, 'MBUS1_EQUIPMENT_IDENTIFIER': {'unit': None,
'value': '3232323241424344313233343536373839'}, 'value': '3232323241424344313233343536373839'},
'HOURLY_GAS_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00', 'MBUS1_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00',
'unit': 'm3', 'unit': 'm3',
'value': 0.107}}, 'value': 0.107}},
{'CHANNEL_ID': 2, {'CHANNEL_ID': 2,
'DEVICE_TYPE': {'unit': None, 'value': 3}, 'MBUS2_DEVICE_TYPE': {'unit': None, 'value': 3},
'EQUIPMENT_IDENTIFIER_GAS': {'unit': None, 'value': None}}], 'MBUS2_EQUIPMENT_IDENTIFIER': {'unit': None,
'value': None}}],
'P1_MESSAGE_HEADER': {'unit': None, 'value': '50'}, 'P1_MESSAGE_HEADER': {'unit': None, 'value': '50'},
'P1_MESSAGE_TIMESTAMP': {'unit': None, 'value': '2017-01-02T18:20:02+00:00'}, 'P1_MESSAGE_TIMESTAMP': {'unit': None, 'value': '2017-01-02T18:20:02+00:00'},
'POWER_EVENT_FAILURE_LOG': {'buffer': [], 'POWER_EVENT_FAILURE_LOG': {'buffer': [],
@ -433,6 +439,8 @@ class TelegramTest(unittest.TestCase):
parser = TelegramParser(telegram_specifications.V5) parser = TelegramParser(telegram_specifications.V5)
telegram = parser.parse(TELEGRAM_V5) telegram = parser.parse(TELEGRAM_V5)
self.maxDiff = None
self.assertEqual( self.assertEqual(
str(telegram), str(telegram),
( (
@ -463,22 +471,24 @@ class TelegramTest(unittest.TestCase):
'INSTANTANEOUS_CURRENT_L2: 0.44 [A]\n' 'INSTANTANEOUS_CURRENT_L2: 0.44 [A]\n'
'INSTANTANEOUS_CURRENT_L3: 0.86 [A]\n' 'INSTANTANEOUS_CURRENT_L3: 0.86 [A]\n'
'TEXT_MESSAGE: None [None]\n' 'TEXT_MESSAGE: None [None]\n'
'DEVICE_TYPE: 3 [None]\n'
'MBUS DEVICE (channel 1)\n'
' DEVICE_TYPE: 3 [None]\n'
' EQUIPMENT_IDENTIFIER_GAS: 3232323241424344313233343536373839 [None]\n'
' HOURLY_GAS_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n'
'MBUS DEVICE (channel 2)\n'
' DEVICE_TYPE: 3 [None]\n'
' EQUIPMENT_IDENTIFIER_GAS: None [None]\n'
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: 0.070 [kW]\n' 'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: 0.070 [kW]\n'
'INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: 0.032 [kW]\n' 'INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: 0.032 [kW]\n'
'INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: 0.142 [kW]\n' 'INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: 0.142 [kW]\n'
'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: 0.000 [kW]\n' 'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: 0.000 [kW]\n'
'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: 0.000 [kW]\n' 'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: 0.000 [kW]\n'
'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: 0.000 [kW]\n' 'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: 0.000 [kW]\n'
'EQUIPMENT_IDENTIFIER_GAS: None [None]\n' 'MBUS1_DEVICE_TYPE: 3 [None]\n'
'HOURLY_GAS_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n' 'MBUS DEVICE (channel 1)\n'
' MBUS1_DEVICE_TYPE: 3 [None]\n'
' MBUS1_EQUIPMENT_IDENTIFIER: 3232323241424344313233343536373839 [None]\n'
' MBUS1_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n'
'MBUS DEVICE (channel 2)\n'
' MBUS2_DEVICE_TYPE: 3 [None]\n'
' MBUS2_EQUIPMENT_IDENTIFIER: None [None]\n'
'MBUS1_EQUIPMENT_IDENTIFIER: 3232323241424344313233343536373839 [None]\n'
'MBUS1_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n'
'MBUS2_DEVICE_TYPE: 3 [None]\n'
'MBUS2_EQUIPMENT_IDENTIFIER: None [None]\n'
) )
) )

View File

@ -210,11 +210,11 @@ class TelegramParserFluviusTest(unittest.TestCase):
assert isinstance(result.ACTUAL_SWITCH_POSITION.value, int) assert isinstance(result.ACTUAL_SWITCH_POSITION.value, int)
assert result.ACTUAL_SWITCH_POSITION.value == 1 assert result.ACTUAL_SWITCH_POSITION.value == 1
# BELGIUM_MAX_POWER_PER_PHASE (0-0:17.0.0) # ACTUAL_TRESHOLD_ELECTRICITY (0-0:17.0.0)
assert isinstance(result.BELGIUM_MAX_POWER_PER_PHASE, CosemObject) assert isinstance(result.ACTUAL_TRESHOLD_ELECTRICITY, CosemObject)
assert result.BELGIUM_MAX_POWER_PER_PHASE.unit == 'kW' assert result.ACTUAL_TRESHOLD_ELECTRICITY.unit == 'kW'
assert isinstance(result.BELGIUM_MAX_POWER_PER_PHASE.value, Decimal) assert isinstance(result.ACTUAL_TRESHOLD_ELECTRICITY.value, Decimal)
assert result.BELGIUM_MAX_POWER_PER_PHASE.value == Decimal('999.9') assert result.ACTUAL_TRESHOLD_ELECTRICITY.value == Decimal('999.9')
# FUSE_THRESHOLD_L1 (1-0:31.4.0) # FUSE_THRESHOLD_L1 (1-0:31.4.0)
assert isinstance(result.FUSE_THRESHOLD_L1, CosemObject) assert isinstance(result.FUSE_THRESHOLD_L1, CosemObject)
@ -227,47 +227,47 @@ class TelegramParserFluviusTest(unittest.TestCase):
assert result.TEXT_MESSAGE.unit is None assert result.TEXT_MESSAGE.unit is None
assert result.TEXT_MESSAGE.value is None assert result.TEXT_MESSAGE.value is None
# BELGIUM_MBUS1_DEVICE_TYPE (0-1:24.1.0) # MBUS1_DEVICE_TYPE (0-1:24.1.0)
assert isinstance(result.BELGIUM_MBUS1_DEVICE_TYPE, CosemObject) assert isinstance(result.MBUS1_DEVICE_TYPE, CosemObject)
assert result.BELGIUM_MBUS1_DEVICE_TYPE.unit is None assert result.MBUS1_DEVICE_TYPE.unit is None
assert isinstance(result.BELGIUM_MBUS1_DEVICE_TYPE.value, int) assert isinstance(result.MBUS1_DEVICE_TYPE.value, int)
assert result.BELGIUM_MBUS1_DEVICE_TYPE.value == 3 assert result.MBUS1_DEVICE_TYPE.value == 3
# BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER (0-1:96.1.1) # MBUS1_EQUIPMENT_IDENTIFIER_ALT (0-1:96.1.1)
assert isinstance(result.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER, CosemObject) assert isinstance(result.MBUS1_EQUIPMENT_IDENTIFIER_ALT, CosemObject)
assert result.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER.unit is None assert result.MBUS1_EQUIPMENT_IDENTIFIER_ALT.unit is None
assert isinstance(result.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER.value, str) assert isinstance(result.MBUS1_EQUIPMENT_IDENTIFIER_ALT.value, str)
assert result.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER.value == '37464C4F32313139303333373333' assert result.MBUS1_EQUIPMENT_IDENTIFIER_ALT.value == '37464C4F32313139303333373333'
# BELGIUM_MBUS1_VALVE_POSITION (0-1:24.4.0) # MBUS1_VALVE_POSITION (0-1:24.4.0)
assert isinstance(result.BELGIUM_MBUS1_VALVE_POSITION, CosemObject) assert isinstance(result.MBUS1_VALVE_POSITION, CosemObject)
assert result.BELGIUM_MBUS1_VALVE_POSITION.unit is None assert result.MBUS1_VALVE_POSITION.unit is None
assert isinstance(result.BELGIUM_MBUS1_VALVE_POSITION.value, int) assert isinstance(result.MBUS1_VALVE_POSITION.value, int)
assert result.BELGIUM_MBUS1_VALVE_POSITION.value == 1 assert result.MBUS1_VALVE_POSITION.value == 1
# BELGIUM_MBUS1_METER_READING2 (0-1:24.2.3) # MBUS1_METER_READING_ALT (0-1:24.2.3)
assert isinstance(result.BELGIUM_MBUS1_METER_READING2, MBusObject) assert isinstance(result.MBUS1_METER_READING_ALT, MBusObject)
assert result.BELGIUM_MBUS1_METER_READING2.unit == 'm3' assert result.MBUS1_METER_READING_ALT.unit == 'm3'
assert isinstance(result.BELGIUM_MBUS1_METER_READING2.value, Decimal) assert isinstance(result.MBUS1_METER_READING_ALT.value, Decimal)
assert result.BELGIUM_MBUS1_METER_READING2.value == Decimal('112.384') assert result.MBUS1_METER_READING_ALT.value == Decimal('112.384')
# BELGIUM_MBUS2_DEVICE_TYPE (0-2:24.1.0) # MBUS2_DEVICE_TYPE (0-2:24.1.0)
assert isinstance(result.BELGIUM_MBUS2_DEVICE_TYPE, CosemObject) assert isinstance(result.MBUS2_DEVICE_TYPE, CosemObject)
assert result.BELGIUM_MBUS2_DEVICE_TYPE.unit is None assert result.MBUS2_DEVICE_TYPE.unit is None
assert isinstance(result.BELGIUM_MBUS2_DEVICE_TYPE.value, int) assert isinstance(result.MBUS2_DEVICE_TYPE.value, int)
assert result.BELGIUM_MBUS2_DEVICE_TYPE.value == 7 assert result.MBUS2_DEVICE_TYPE.value == 7
# BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER (0-2:96.1.1) # MBUS2_EQUIPMENT_IDENTIFIER_ALT (0-2:96.1.1)
assert isinstance(result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER, CosemObject) assert isinstance(result.MBUS2_EQUIPMENT_IDENTIFIER_ALT, CosemObject)
assert result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER.unit is None assert result.MBUS2_EQUIPMENT_IDENTIFIER_ALT.unit is None
assert isinstance(result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER.value, str) assert isinstance(result.MBUS2_EQUIPMENT_IDENTIFIER_ALT.value, str)
assert result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER.value == '3853414731323334353637383930' assert result.MBUS2_EQUIPMENT_IDENTIFIER_ALT.value == '3853414731323334353637383930'
# BELGIUM_MBUS2_METER_READING1 (0-1:24.2.1) # MBUS2_METER_READING (0-1:24.2.1)
assert isinstance(result.BELGIUM_MBUS2_METER_READING1, MBusObject) assert isinstance(result.MBUS2_METER_READING, MBusObject)
assert result.BELGIUM_MBUS2_METER_READING1.unit == 'm3' assert result.MBUS2_METER_READING.unit == 'm3'
assert isinstance(result.BELGIUM_MBUS2_METER_READING1.value, Decimal) assert isinstance(result.MBUS2_METER_READING.value, Decimal)
assert result.BELGIUM_MBUS2_METER_READING1.value == Decimal('872.234') assert result.MBUS2_METER_READING.value == Decimal('872.234')
def test_checksum_valid(self): def test_checksum_valid(self):
# No exception is raised. # No exception is raised.

View File

@ -172,12 +172,6 @@ class TelegramParserV5Test(unittest.TestCase):
assert telegram.TEXT_MESSAGE.unit is None assert telegram.TEXT_MESSAGE.unit is None
assert telegram.TEXT_MESSAGE.value is None assert telegram.TEXT_MESSAGE.value is None
# DEVICE_TYPE (0-x:24.1.0)
assert isinstance(telegram.DEVICE_TYPE, CosemObject)
assert telegram.DEVICE_TYPE.unit is None
assert isinstance(telegram.DEVICE_TYPE.value, int)
assert telegram.DEVICE_TYPE.value == 3
# INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE (1-0:21.7.0) # INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE (1-0:21.7.0)
assert isinstance(telegram.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE, CosemObject) assert isinstance(telegram.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE, CosemObject)
assert telegram.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE.unit == 'kW' assert telegram.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE.unit == 'kW'
@ -219,23 +213,23 @@ class TelegramParserV5Test(unittest.TestCase):
gas_meter_devices = telegram.MBUS_DEVICES gas_meter_devices = telegram.MBUS_DEVICES
gas_meter_device = gas_meter_devices[0] gas_meter_device = gas_meter_devices[0]
# EQUIPMENT_IDENTIFIER_GAS (0-x:96.1.0) # MBUS1_DEVICE_TYPE (0-1:96.1.0)
assert isinstance(gas_meter_device.DEVICE_TYPE, CosemObject) assert isinstance(gas_meter_device.MBUS1_DEVICE_TYPE, CosemObject)
assert gas_meter_device.DEVICE_TYPE.unit is None assert gas_meter_device.MBUS1_DEVICE_TYPE.unit is None
assert isinstance(gas_meter_device.DEVICE_TYPE.value, int) assert isinstance(gas_meter_device.MBUS1_DEVICE_TYPE.value, int)
assert gas_meter_device.DEVICE_TYPE.value == 3 assert gas_meter_device.MBUS1_DEVICE_TYPE.value == 3
# EQUIPMENT_IDENTIFIER_GAS (0-x:96.1.0) # MBUS1_EQUIPMENT_IDENTIFIER (0-1:96.1.0)
assert isinstance(gas_meter_device.EQUIPMENT_IDENTIFIER_GAS, CosemObject) assert isinstance(gas_meter_device.MBUS1_EQUIPMENT_IDENTIFIER, CosemObject)
assert gas_meter_device.EQUIPMENT_IDENTIFIER_GAS.unit is None assert gas_meter_device.MBUS1_EQUIPMENT_IDENTIFIER.unit is None
assert isinstance(gas_meter_device.EQUIPMENT_IDENTIFIER_GAS.value, str) assert isinstance(gas_meter_device.MBUS1_EQUIPMENT_IDENTIFIER.value, str)
assert gas_meter_device.EQUIPMENT_IDENTIFIER_GAS.value == '3232323241424344313233343536373839' assert gas_meter_device.MBUS1_EQUIPMENT_IDENTIFIER.value == '3232323241424344313233343536373839'
# HOURLY_GAS_METER_READING (0-1:24.2.1) # MBUS1_METER_READING (0-1:24.2.1)
assert isinstance(gas_meter_device.HOURLY_GAS_METER_READING, MBusObject) assert isinstance(gas_meter_device.MBUS1_METER_READING, MBusObject)
assert gas_meter_device.HOURLY_GAS_METER_READING.unit == 'm3' assert gas_meter_device.MBUS1_METER_READING.unit == 'm3'
assert isinstance(telegram.HOURLY_GAS_METER_READING.value, Decimal) assert isinstance(telegram.MBUS1_METER_READING.value, Decimal)
assert gas_meter_device.HOURLY_GAS_METER_READING.value == Decimal('0.107') assert gas_meter_device.MBUS1_METER_READING.value == Decimal('0.107')
def test_checksum_valid(self): def test_checksum_valid(self):
# No exception is raised. # No exception is raised.
@ -270,8 +264,8 @@ class TelegramParserV5Test(unittest.TestCase):
parser = TelegramParser(telegram_specifications.V5) parser = TelegramParser(telegram_specifications.V5)
telegram = parser.parse(invalid_date_telegram) telegram = parser.parse(invalid_date_telegram)
# HOURLY_GAS_METER_READING (0-1:24.2.1) # MBUS1_METER_READING (0-1:24.2.1)
assert isinstance(telegram.HOURLY_GAS_METER_READING, MBusObject) assert isinstance(telegram.MBUS1_METER_READING, MBusObject)
assert telegram.HOURLY_GAS_METER_READING.unit is None assert telegram.MBUS1_METER_READING.unit is None
assert isinstance(telegram.HOURLY_GAS_METER_READING.value, Decimal) assert isinstance(telegram.MBUS1_METER_READING.value, Decimal)
assert telegram.HOURLY_GAS_METER_READING.value == Decimal('0.000') assert telegram.MBUS1_METER_READING.value == Decimal('0.000')