Merge pull request #30 from jk-5/sagemcom-t210-d

Added missing values for 3-phase sagemcom TD210-D meter
This commit is contained in:
Nigel Dokter 2018-09-12 23:45:29 +02:00 committed by GitHub
commit 8582395017
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
3 changed files with 56 additions and 0 deletions

View File

@ -17,6 +17,7 @@ EQUIPMENT_IDENTIFIER = r'\d-\d:96\.1\.1.+?\r\n'
CURRENT_ELECTRICITY_USAGE = r'\d-\d:1\.7\.0.+?\r\n'
CURRENT_ELECTRICITY_DELIVERY = r'\d-\d:2\.7\.0.+?\r\n'
LONG_POWER_FAILURE_COUNT = r'96\.7\.9.+?\r\n'
SHORT_POWER_FAILURE_COUNT = r'96\.7\.21.+?\r\n'
POWER_EVENT_FAILURE_LOG = r'99\.97\.0.+?\r\n'
VOLTAGE_SAG_L1_COUNT = r'\d-\d:32\.32\.0.+?\r\n'
VOLTAGE_SAG_L2_COUNT = r'\d-\d:52\.32\.0.+?\r\n'
@ -24,6 +25,12 @@ VOLTAGE_SAG_L3_COUNT = r'\d-\d:72\.32\.0.+?\r\n'
VOLTAGE_SWELL_L1_COUNT = r'\d-\d:32\.36\.0.+?\r\n'
VOLTAGE_SWELL_L2_COUNT = r'\d-\d:52\.36\.0.+?\r\n'
VOLTAGE_SWELL_L3_COUNT = r'\d-\d:72\.36\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L1 = r'\d-\d:32\.7\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L2 = r'\d-\d:52\.7\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L3 = r'\d-\d:72\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L1 = r'\d-\d:31\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L2 = r'\d-\d:51\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L3 = r'\d-\d:71\.7\.0.+?\r\n'
TEXT_MESSAGE_CODE = r'\d-\d:96\.13\.1.+?\r\n'
TEXT_MESSAGE = r'\d-\d:96\.13\.0.+?\r\n'
DEVICE_TYPE = r'\d-\d:24\.1\.0.+?\r\n'

View File

@ -96,6 +96,7 @@ V5 = {
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
obis.SHORT_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
# POWER_EVENT_FAILURE_LOG: ProfileGenericParser(), TODO
obis.VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
@ -103,6 +104,12 @@ V5 = {
obis.VOLTAGE_SWELL_L1_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SWELL_L2_COUNT: CosemParser(ValueParser(int)),
obis.VOLTAGE_SWELL_L3_COUNT: CosemParser(ValueParser(int)),
obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)),
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
obis.DEVICE_TYPE: CosemParser(ValueParser(int)),
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),

View File

@ -87,6 +87,12 @@ class TelegramParserV5Test(unittest.TestCase):
assert isinstance(result[obis.LONG_POWER_FAILURE_COUNT].value, int)
assert result[obis.LONG_POWER_FAILURE_COUNT].value == 0
# SHORT_POWER_FAILURE_COUNT (1-0:96.7.21)
assert isinstance(result[obis.SHORT_POWER_FAILURE_COUNT], CosemObject)
assert result[obis.SHORT_POWER_FAILURE_COUNT].unit is None
assert isinstance(result[obis.SHORT_POWER_FAILURE_COUNT].value, int)
assert result[obis.SHORT_POWER_FAILURE_COUNT].value == 13
# VOLTAGE_SAG_L1_COUNT (1-0:32.32.0)
assert isinstance(result[obis.VOLTAGE_SAG_L1_COUNT], CosemObject)
assert result[obis.VOLTAGE_SAG_L1_COUNT].unit is None
@ -123,6 +129,42 @@ class TelegramParserV5Test(unittest.TestCase):
assert isinstance(result[obis.VOLTAGE_SWELL_L3_COUNT].value, int)
assert result[obis.VOLTAGE_SWELL_L3_COUNT].value == 0
# INSTANTANEOUS_VOLTAGE_L1 (1-0:32.7.0)
assert isinstance(result[obis.INSTANTANEOUS_VOLTAGE_L1], CosemObject)
assert result[obis.INSTANTANEOUS_VOLTAGE_L1].unit == 'V'
assert isinstance(result[obis.INSTANTANEOUS_VOLTAGE_L1].value, Decimal)
assert result[obis.INSTANTANEOUS_VOLTAGE_L1].value == Decimal('230.0')
# INSTANTANEOUS_VOLTAGE_L2 (1-0:52.7.0)
assert isinstance(result[obis.INSTANTANEOUS_VOLTAGE_L2], CosemObject)
assert result[obis.INSTANTANEOUS_VOLTAGE_L2].unit == 'V'
assert isinstance(result[obis.INSTANTANEOUS_VOLTAGE_L2].value, Decimal)
assert result[obis.INSTANTANEOUS_VOLTAGE_L2].value == Decimal('230.0')
# INSTANTANEOUS_VOLTAGE_L3 (1-0:72.7.0)
assert isinstance(result[obis.INSTANTANEOUS_VOLTAGE_L3], CosemObject)
assert result[obis.INSTANTANEOUS_VOLTAGE_L3].unit == 'V'
assert isinstance(result[obis.INSTANTANEOUS_VOLTAGE_L3].value, Decimal)
assert result[obis.INSTANTANEOUS_VOLTAGE_L3].value == Decimal('229.0')
# INSTANTANEOUS_CURRENT_L1 (1-0:31.7.0)
assert isinstance(result[obis.INSTANTANEOUS_CURRENT_L1], CosemObject)
assert result[obis.INSTANTANEOUS_CURRENT_L1].unit == 'A'
assert isinstance(result[obis.INSTANTANEOUS_CURRENT_L1].value, Decimal)
assert result[obis.INSTANTANEOUS_CURRENT_L1].value == Decimal('0.48')
# INSTANTANEOUS_CURRENT_L2 (1-0:51.7.0)
assert isinstance(result[obis.INSTANTANEOUS_CURRENT_L2], CosemObject)
assert result[obis.INSTANTANEOUS_CURRENT_L2].unit == 'A'
assert isinstance(result[obis.INSTANTANEOUS_CURRENT_L2].value, Decimal)
assert result[obis.INSTANTANEOUS_CURRENT_L2].value == Decimal('0.44')
# INSTANTANEOUS_CURRENT_L3 (1-0:71.7.0)
assert isinstance(result[obis.INSTANTANEOUS_CURRENT_L3], CosemObject)
assert result[obis.INSTANTANEOUS_CURRENT_L3].unit == 'A'
assert isinstance(result[obis.INSTANTANEOUS_CURRENT_L3].value, Decimal)
assert result[obis.INSTANTANEOUS_CURRENT_L3].value == Decimal('0.86')
# TEXT_MESSAGE (0-0:96.13.0)
assert isinstance(result[obis.TEXT_MESSAGE], CosemObject)
assert result[obis.TEXT_MESSAGE].unit is None