Fix parsing tests and line start matching (#132)

* Raise parsing exception and check it in tests

* use multiline regex and match everything at the line start
This commit is contained in:
dupondje 2023-04-14 16:51:01 +02:00 committed by GitHub
parent ae8a2baaab
commit 84973872af
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
8 changed files with 119 additions and 96 deletions

View File

@ -6,61 +6,61 @@ refactored to full line signatures to maintain backwards compatibility.
Might be refactored in a backwards incompatible way as soon as proper telegram
objects are introduced.
"""
P1_MESSAGE_HEADER = r'\d-\d:0\.2\.8.+?\r\n'
P1_MESSAGE_TIMESTAMP = r'\d-\d:1\.0\.0.+?\r\n'
ELECTRICITY_USED_TARIFF_1 = r'\d-\d:1\.8\.1.+?\r\n'
ELECTRICITY_USED_TARIFF_2 = r'\d-\d:1\.8\.2.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_1 = r'\d-\d:2\.8\.1.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_2 = r'\d-\d:2\.8\.2.+?\r\n'
CURRENT_REACTIVE_IMPORTED = r'\d-\d:3\.7\.0.+?\r\n'
ELECTRICITY_REACTIVE_IMPORTED_TOTAL = r'\d-\d:3\.8\.0.+?\r\n'
ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1 = r'\d-\d:3\.8\.1.+?\r\n'
ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2 = r'\d-\d:3\.8\.2.+?\r\n'
CURRENT_REACTIVE_EXPORTED = r'\d-\d:4\.7\.0.+?\r\n'
ELECTRICITY_REACTIVE_EXPORTED_TOTAL = r'\d-\d:4\.8\.0.+?\r\n'
ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1 = r'\d-\d:4\.8\.1.+?\r\n'
ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2 = r'\d-\d:4\.8\.2.+?\r\n'
ELECTRICITY_ACTIVE_TARIFF = r'\d-\d:96\.14\.0.+?\r\n'
EQUIPMENT_IDENTIFIER = r'\d-\d:96\.1\.1.+?\r\n'
CURRENT_ELECTRICITY_USAGE = r'\d-\d:1\.7\.0.+?\r\n'
CURRENT_ELECTRICITY_DELIVERY = r'\d-\d:2\.7\.0.+?\r\n'
LONG_POWER_FAILURE_COUNT = r'\d-\d:96\.7\.9.+?\r\n'
SHORT_POWER_FAILURE_COUNT = r'\d-\d:96\.7\.21.+?\r\n'
POWER_EVENT_FAILURE_LOG = r'\d-\d:99\.97\.0.+?\r\n'
VOLTAGE_SAG_L1_COUNT = r'\d-\d:32\.32\.0.+?\r\n'
VOLTAGE_SAG_L2_COUNT = r'\d-\d:52\.32\.0.+?\r\n'
VOLTAGE_SAG_L3_COUNT = r'\d-\d:72\.32\.0.+?\r\n'
VOLTAGE_SWELL_L1_COUNT = r'\d-\d:32\.36\.0.+?\r\n'
VOLTAGE_SWELL_L2_COUNT = r'\d-\d:52\.36\.0.+?\r\n'
VOLTAGE_SWELL_L3_COUNT = r'\d-\d:72\.36\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L1 = r'\d-\d:32\.7\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L2 = r'\d-\d:52\.7\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L3 = r'\d-\d:72\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L1 = r'\d-\d:31\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L2 = r'\d-\d:51\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L3 = r'\d-\d:71\.7\.0.+?\r\n'
TEXT_MESSAGE_CODE = r'\d-\d:96\.13\.1.+?\r\n'
TEXT_MESSAGE = r'\d-\d:96\.13\.0.+?\r\n'
DEVICE_TYPE = r'\d-\d:24\.1\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE = r'\d-\d:21\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE = r'\d-\d:41\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE = r'\d-\d:61\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r'\d-\d:22\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r'\d-\d:42\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r'\d-\d:62\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L1_POSITIVE = r'\d-\d:23\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L1_NEGATIVE = r'\d-\d:24\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L2_POSITIVE = r'\d-\d:43\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L2_NEGATIVE = r'\d-\d:44\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L3_POSITIVE = r'\d-\d:63\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L3_NEGATIVE = r'\d-\d:64\.7\.0.+?\r\n'
EQUIPMENT_IDENTIFIER_GAS = r'\d-\d:96\.1\.0.+?\r\n'
P1_MESSAGE_HEADER = r'^\d-\d:0\.2\.8.+?\r\n'
P1_MESSAGE_TIMESTAMP = r'^\d-\d:1\.0\.0.+?\r\n'
ELECTRICITY_USED_TARIFF_1 = r'^\d-\d:1\.8\.1.+?\r\n'
ELECTRICITY_USED_TARIFF_2 = r'^\d-\d:1\.8\.2.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_1 = r'^\d-\d:2\.8\.1.+?\r\n'
ELECTRICITY_DELIVERED_TARIFF_2 = r'^\d-\d:2\.8\.2.+?\r\n'
CURRENT_REACTIVE_IMPORTED = r'^\d-\d:3\.7\.0.+?\r\n'
ELECTRICITY_REACTIVE_IMPORTED_TOTAL = r'^\d-\d:3\.8\.0.+?\r\n'
ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1 = r'^\d-\d:3\.8\.1.+?\r\n'
ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2 = r'^\d-\d:3\.8\.2.+?\r\n'
CURRENT_REACTIVE_EXPORTED = r'^\d-\d:4\.7\.0.+?\r\n'
ELECTRICITY_REACTIVE_EXPORTED_TOTAL = r'^\d-\d:4\.8\.0.+?\r\n'
ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1 = r'^\d-\d:4\.8\.1.+?\r\n'
ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2 = r'^\d-\d:4\.8\.2.+?\r\n'
ELECTRICITY_ACTIVE_TARIFF = r'^\d-\d:96\.14\.0.+?\r\n'
EQUIPMENT_IDENTIFIER = r'^\d-\d:96\.1\.1.+?\r\n'
CURRENT_ELECTRICITY_USAGE = r'^\d-\d:1\.7\.0.+?\r\n'
CURRENT_ELECTRICITY_DELIVERY = r'^\d-\d:2\.7\.0.+?\r\n'
LONG_POWER_FAILURE_COUNT = r'^\d-\d:96\.7\.9.+?\r\n'
SHORT_POWER_FAILURE_COUNT = r'^\d-\d:96\.7\.21.+?\r\n'
POWER_EVENT_FAILURE_LOG = r'^\d-\d:99\.97\.0.+?\r\n'
VOLTAGE_SAG_L1_COUNT = r'^\d-\d:32\.32\.0.+?\r\n'
VOLTAGE_SAG_L2_COUNT = r'^\d-\d:52\.32\.0.+?\r\n'
VOLTAGE_SAG_L3_COUNT = r'^\d-\d:72\.32\.0.+?\r\n'
VOLTAGE_SWELL_L1_COUNT = r'^\d-\d:32\.36\.0.+?\r\n'
VOLTAGE_SWELL_L2_COUNT = r'^\d-\d:52\.36\.0.+?\r\n'
VOLTAGE_SWELL_L3_COUNT = r'^\d-\d:72\.36\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L1 = r'^\d-\d:32\.7\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L2 = r'^\d-\d:52\.7\.0.+?\r\n'
INSTANTANEOUS_VOLTAGE_L3 = r'^\d-\d:72\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L1 = r'^\d-\d:31\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L2 = r'^\d-\d:51\.7\.0.+?\r\n'
INSTANTANEOUS_CURRENT_L3 = r'^\d-\d:71\.7\.0.+?\r\n'
TEXT_MESSAGE_CODE = r'^\d-\d:96\.13\.1.+?\r\n'
TEXT_MESSAGE = r'^\d-\d:96\.13\.0.+?\r\n'
DEVICE_TYPE = r'^\d-\d:24\.1\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE = r'^\d-\d:21\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE = r'^\d-\d:41\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE = r'^\d-\d:61\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r'^\d-\d:22\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r'^\d-\d:42\.7\.0.+?\r\n'
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r'^\d-\d:62\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L1_POSITIVE = r'^\d-\d:23\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L1_NEGATIVE = r'^\d-\d:24\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L2_POSITIVE = r'^\d-\d:43\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L2_NEGATIVE = r'^\d-\d:44\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L3_POSITIVE = r'^\d-\d:63\.7\.0.+?\r\n'
INSTANTANEOUS_REACTIVE_POWER_L3_NEGATIVE = r'^\d-\d:64\.7\.0.+?\r\n'
EQUIPMENT_IDENTIFIER_GAS = r'^\d-\d:96\.1\.0.+?\r\n'
# TODO differences between gas meter readings in v3 and lower and v4 and up
HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.1.+?\r\n'
GAS_METER_READING = r'\d-\d:24\.3\.0.+?\r\n.+?\r\n'
ACTUAL_TRESHOLD_ELECTRICITY = r'\d-\d:17\.0\.0.+?\r\n'
ACTUAL_SWITCH_POSITION = r'\d-\d:96\.3\.10.+?\r\n'
VALVE_POSITION_GAS = r'\d-\d:24\.4\.0.+?\r\n'
HOURLY_GAS_METER_READING = r'^\d-\d:24\.2\.1.+?\r\n'
GAS_METER_READING = r'^\d-\d:24\.3\.0.+?\r\n.+?\r\n'
ACTUAL_TRESHOLD_ELECTRICITY = r'^\d-\d:17\.0\.0.+?\r\n'
ACTUAL_SWITCH_POSITION = r'^\d-\d:96\.3\.10.+?\r\n'
VALVE_POSITION_GAS = r'^\d-\d:24\.4\.0.+?\r\n'
# TODO 17.0.0
# TODO 96.3.10
@ -75,50 +75,50 @@ ELECTRICITY_DELIVERED_TARIFF_ALL = (
)
# International generalized additions
ELECTRICITY_IMPORTED_TOTAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
ELECTRICITY_EXPORTED_TOTAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
ELECTRICITY_IMPORTED_TOTAL = r'^\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
ELECTRICITY_EXPORTED_TOTAL = r'^\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
# International non generalized additions (country specific) / risk for necessary refactoring
BELGIUM_VERSION_INFORMATION = r'\d-\d:96\.1\.4.+?\r\n'
BELGIUM_EQUIPMENT_IDENTIFIER = r'\d-0:96\.1\.1.+?\r\n'
BELGIUM_CURRENT_AVERAGE_DEMAND = r'\d-\d:1\.4\.0.+?\r\n'
BELGIUM_MAXIMUM_DEMAND_MONTH = r'\d-\d:1\.6\.0.+?\r\n'
BELGIUM_MAXIMUM_DEMAND_13_MONTHS = r'\d-\d:98\.1\.0.+?\r\n'
BELGIUM_MAX_POWER_PER_PHASE = r'\d-\d:17\.0\.0.+?\r\n' # Applicable when power limitation is active
BELGIUM_MAX_CURRENT_PER_PHASE = r'\d-\d:31\.4\.0.+?\r\n' # Applicable when current limitation is active
BELGIUM_VERSION_INFORMATION = r'^\d-\d:96\.1\.4.+?\r\n'
BELGIUM_EQUIPMENT_IDENTIFIER = r'^\d-0:96\.1\.1.+?\r\n'
BELGIUM_CURRENT_AVERAGE_DEMAND = r'^\d-\d:1\.4\.0.+?\r\n'
BELGIUM_MAXIMUM_DEMAND_MONTH = r'^\d-\d:1\.6\.0.+?\r\n'
BELGIUM_MAXIMUM_DEMAND_13_MONTHS = r'^\d-\d:98\.1\.0.+?\r\n'
BELGIUM_MAX_POWER_PER_PHASE = r'^\d-\d:17\.0\.0.+?\r\n' # Applicable when power limitation is active
BELGIUM_MAX_CURRENT_PER_PHASE = r'^\d-\d:31\.4\.0.+?\r\n' # Applicable when current limitation is active
# Multiple 'slaves' can be linked to the main device.
# Mostly MBUS1 = GAS METER with values on 24.2.3
# While WATER METER reports it's values on 24.2.1
# The GAS METER also reports its valve state on 24.4.0
# Dev type for gas = 7 and water = 8
BELGIUM_MBUS1_DEVICE_TYPE = r'\d-1:24\.1\.0.+?\r\n'
BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER = r'\d-1:96\.1\.1.+?\r\n'
BELGIUM_MBUS1_VALVE_POSITION = r'\d-1:24\.4\.0.+?\r\n'
BELGIUM_MBUS1_METER_READING1 = r'\d-1:24\.2\.1.+?\r\n'
BELGIUM_MBUS1_METER_READING2 = r'\d-1:24\.2\.3.+?\r\n'
BELGIUM_MBUS1_DEVICE_TYPE = r'^\d-1:24\.1\.0.+?\r\n'
BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER = r'^\d-1:96\.1\.1.+?\r\n'
BELGIUM_MBUS1_VALVE_POSITION = r'^\d-1:24\.4\.0.+?\r\n'
BELGIUM_MBUS1_METER_READING1 = r'^\d-1:24\.2\.1.+?\r\n'
BELGIUM_MBUS1_METER_READING2 = r'^\d-1:24\.2\.3.+?\r\n'
BELGIUM_MBUS2_DEVICE_TYPE = r'\d-2:24\.1\.0.+?\r\n'
BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER = r'\d-2:96\.1\.1.+?\r\n'
BELGIUM_MBUS2_VALVE_POSITION = r'\d-2:24\.4\.0.+?\r\n'
BELGIUM_MBUS2_METER_READING1 = r'\d-2:24\.2\.1.+?\r\n'
BELGIUM_MBUS2_METER_READING2 = r'\d-2:24\.2\.3.+?\r\n'
BELGIUM_MBUS2_DEVICE_TYPE = r'^\d-2:24\.1\.0.+?\r\n'
BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER = r'^\d-2:96\.1\.1.+?\r\n'
BELGIUM_MBUS2_VALVE_POSITION = r'^\d-2:24\.4\.0.+?\r\n'
BELGIUM_MBUS2_METER_READING1 = r'^\d-2:24\.2\.1.+?\r\n'
BELGIUM_MBUS2_METER_READING2 = r'^\d-2:24\.2\.3.+?\r\n'
BELGIUM_MBUS3_DEVICE_TYPE = r'\d-3:24\.1\.0.+?\r\n'
BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER = r'\d-3:96\.1\.1.+?\r\n'
BELGIUM_MBUS3_VALVE_POSITION = r'\d-3:24\.4\.0.+?\r\n'
BELGIUM_MBUS3_METER_READING1 = r'\d-3:24\.2\.1.+?\r\n'
BELGIUM_MBUS3_METER_READING2 = r'\d-3:24\.2\.3.+?\r\n'
BELGIUM_MBUS3_DEVICE_TYPE = r'^\d-3:24\.1\.0.+?\r\n'
BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER = r'^\d-3:96\.1\.1.+?\r\n'
BELGIUM_MBUS3_VALVE_POSITION = r'^\d-3:24\.4\.0.+?\r\n'
BELGIUM_MBUS3_METER_READING1 = r'^\d-3:24\.2\.1.+?\r\n'
BELGIUM_MBUS3_METER_READING2 = r'^\d-3:24\.2\.3.+?\r\n'
BELGIUM_MBUS4_DEVICE_TYPE = r'\d-4:24\.1\.0.+?\r\n'
BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER = r'\d-4:96\.1\.1.+?\r\n'
BELGIUM_MBUS4_VALVE_POSITION = r'\d-4:24\.4\.0.+?\r\n'
BELGIUM_MBUS4_METER_READING1 = r'\d-4:24\.2\.1.+?\r\n'
BELGIUM_MBUS4_METER_READING2 = r'\d-4:24\.2\.3.+?\r\n'
BELGIUM_MBUS4_DEVICE_TYPE = r'^\d-4:24\.1\.0.+?\r\n'
BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER = r'^\d-4:96\.1\.1.+?\r\n'
BELGIUM_MBUS4_VALVE_POSITION = r'^\d-4:24\.4\.0.+?\r\n'
BELGIUM_MBUS4_METER_READING1 = r'^\d-4:24\.2\.1.+?\r\n'
BELGIUM_MBUS4_METER_READING2 = r'^\d-4:24\.2\.3.+?\r\n'
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'\d-\d:42\.0\.0.+?\r\n' # Logical device name
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'^\d-\d:42\.0\.0.+?\r\n' # Logical device name
Q3D_EQUIPMENT_IDENTIFIER = r'\d-\d:0\.0\.0.+?\r\n' # Logical device name
Q3D_EQUIPMENT_STATE = r'\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal)
Q3D_EQUIPMENT_SERIALNUMBER = r'\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber
Q3D_EQUIPMENT_IDENTIFIER = r'^\d-\d:0\.0\.0.+?\r\n' # Logical device name
Q3D_EQUIPMENT_STATE = r'^\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal)
Q3D_EQUIPMENT_SERIALNUMBER = r'^\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber

View File

@ -29,11 +29,11 @@ class TelegramParser(object):
self.telegram_specification = telegram_specification
# Regexes are compiled once to improve performance
self.telegram_specification_regexes = {
signature: re.compile(signature, re.DOTALL)
signature: re.compile(signature, re.DOTALL | re.MULTILINE)
for signature in self.telegram_specification['objects'].keys()
}
def parse(self, telegram_data, encryption_key="", authentication_key=""): # noqa: C901
def parse(self, telegram_data, encryption_key="", authentication_key="", throw_ex=False): # noqa: C901
"""
Parse telegram from string to dict.
The telegram str type makes python 2.x integration easier.
@ -93,9 +93,14 @@ class TelegramParser(object):
for match in matches:
try:
dsmr_object = parser.parse(match)
except Exception:
except ParseError:
logger.error("ignore line with signature {}, because parsing failed.".format(signature),
exc_info=True)
if throw_ex:
raise
except Exception as err:
logger.error("Unexpected {}: {}".format(type(err), err))
raise
else:
telegram.add(obis_reference=signature, dsmr_object=dsmr_object)

View File

@ -18,7 +18,10 @@ class TelegramParserFluviusTest(unittest.TestCase):
def test_parse(self):
parser = TelegramParser(telegram_specifications.BELGIUM_FLUVIUS)
result = parser.parse(TELEGRAM_FLUVIUS_V171)
try:
result = parser.parse(TELEGRAM_FLUVIUS_V171, throw_ex=True)
except Exception as ex:
assert False, f"parse trigged an exception {ex}"
# BELGIUM_VERSION_INFORMATION (0-0:96.1.4)
assert isinstance(result[obis.BELGIUM_VERSION_INFORMATION], CosemObject)

View File

@ -15,7 +15,10 @@ class TelegramParserIskraIETest(unittest.TestCase):
def test_parse(self):
parser = TelegramParser(telegram_specifications.ISKRA_IE)
result = parser.parse(TELEGRAM_ISKRA_IE)
try:
result = parser.parse(TELEGRAM_ISKRA_IE, throw_ex=True)
except Exception as ex:
assert False, f"parse trigged an exception {ex}"
# EQUIPMENT_IDENTIFIER_GAS (0-0:96.1.0)
assert isinstance(result[obis.EQUIPMENT_IDENTIFIER_GAS], CosemObject)

View File

@ -14,7 +14,10 @@ class TelegramParserV2_2Test(unittest.TestCase):
def test_parse(self):
parser = TelegramParser(telegram_specifications.V2_2)
result = parser.parse(TELEGRAM_V2_2)
try:
result = parser.parse(TELEGRAM_V2_2, throw_ex=True)
except Exception as ex:
assert False, f"parse trigged an exception {ex}"
# ELECTRICITY_USED_TARIFF_1 (1-0:1.8.1)
assert isinstance(result[obis.ELECTRICITY_USED_TARIFF_1], CosemObject)

View File

@ -14,7 +14,10 @@ class TelegramParserV3Test(unittest.TestCase):
def test_parse(self):
parser = TelegramParser(telegram_specifications.V3)
result = parser.parse(TELEGRAM_V3)
try:
result = parser.parse(TELEGRAM_V3, throw_ex=True)
except Exception as ex:
assert False, f"parse trigged an exception {ex}"
# ELECTRICITY_USED_TARIFF_1 (1-0:1.8.1)
assert isinstance(result[obis.ELECTRICITY_USED_TARIFF_1], CosemObject)

View File

@ -17,7 +17,10 @@ class TelegramParserV4_2Test(unittest.TestCase):
def test_parse(self):
parser = TelegramParser(telegram_specifications.V4)
result = parser.parse(TELEGRAM_V4_2)
try:
result = parser.parse(TELEGRAM_V4_2, throw_ex=True)
except Exception as ex:
assert False, f"parse trigged an exception {ex}"
# P1_MESSAGE_HEADER (1-3:0.2.8)
assert isinstance(result[obis.P1_MESSAGE_HEADER], CosemObject)

View File

@ -17,7 +17,10 @@ class TelegramParserV5Test(unittest.TestCase):
def test_parse(self):
parser = TelegramParser(telegram_specifications.V5)
telegram = parser.parse(TELEGRAM_V5)
try:
telegram = parser.parse(TELEGRAM_V5, throw_ex=True)
except Exception as ex:
assert False, f"parse trigged an exception {ex}"
# P1_MESSAGE_HEADER (1-3:0.2.8)
assert isinstance(telegram.P1_MESSAGE_HEADER, CosemObject)