Remove BELGIUM_MAX_POWER_PER_PHASE (#144)
This commit removes BELGIUM_MAX_POWER_PER_PHASE and uses ACTUAL_TRESHOLD_ELECTRICITY as this has same regex. So useless to keep the BELIUM variant.
This commit is contained in:
parent
d2ff6f4bb9
commit
739419e3ee
@ -91,7 +91,6 @@ BELGIUM_EQUIPMENT_IDENTIFIER = r'^\d-0:96\.1\.1.+?\r\n'
|
||||
BELGIUM_CURRENT_AVERAGE_DEMAND = r'^\d-\d:1\.4\.0.+?\r\n'
|
||||
BELGIUM_MAXIMUM_DEMAND_MONTH = r'^\d-\d:1\.6\.0.+?\r\n'
|
||||
BELGIUM_MAXIMUM_DEMAND_13_MONTHS = r'^\d-\d:98\.1\.0.+?\r\n'
|
||||
BELGIUM_MAX_POWER_PER_PHASE = r'^\d-\d:17\.0\.0.+?\r\n' # Applicable when power limitation is active
|
||||
|
||||
# Multiple 'slaves' can be linked to the main device.
|
||||
# Mostly MBUS1 = GAS METER with values on 24.2.3
|
||||
|
@ -625,9 +625,9 @@ BELGIUM_FLUVIUS = {
|
||||
'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MAX_POWER_PER_PHASE,
|
||||
'obis_reference': obis.ACTUAL_TRESHOLD_ELECTRICITY,
|
||||
'value_parser': CosemParser(ValueParser(Decimal)),
|
||||
'value_name': 'BELGIUM_MAX_POWER_PER_PHASE'
|
||||
'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY'
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.FUSE_THRESHOLD_L1,
|
||||
@ -1233,7 +1233,7 @@ EON_HUNGARY = {
|
||||
# This seems to be wrong in documentation, it's not 0-0:96.50.68, but 0-0:96.3.10
|
||||
},
|
||||
{
|
||||
'obis_reference': obis.BELGIUM_MAX_POWER_PER_PHASE,
|
||||
'obis_reference': obis.ACTUAL_TRESHOLD_ELECTRICITY,
|
||||
'value_parser': CosemParser(ValueParser(Decimal)),
|
||||
'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY'
|
||||
},
|
||||
|
@ -211,11 +211,11 @@ class TelegramParserFluviusTest(unittest.TestCase):
|
||||
assert isinstance(result.ACTUAL_SWITCH_POSITION.value, int)
|
||||
assert result.ACTUAL_SWITCH_POSITION.value == 1
|
||||
|
||||
# BELGIUM_MAX_POWER_PER_PHASE (0-0:17.0.0)
|
||||
assert isinstance(result.BELGIUM_MAX_POWER_PER_PHASE, CosemObject)
|
||||
assert result.BELGIUM_MAX_POWER_PER_PHASE.unit == 'kW'
|
||||
assert isinstance(result.BELGIUM_MAX_POWER_PER_PHASE.value, Decimal)
|
||||
assert result.BELGIUM_MAX_POWER_PER_PHASE.value == Decimal('999.9')
|
||||
# ACTUAL_TRESHOLD_ELECTRICITY (0-0:17.0.0)
|
||||
assert isinstance(result.ACTUAL_TRESHOLD_ELECTRICITY, CosemObject)
|
||||
assert result.ACTUAL_TRESHOLD_ELECTRICITY.unit == 'kW'
|
||||
assert isinstance(result.ACTUAL_TRESHOLD_ELECTRICITY.value, Decimal)
|
||||
assert result.ACTUAL_TRESHOLD_ELECTRICITY.value == Decimal('999.9')
|
||||
|
||||
# FUSE_THRESHOLD_L1 (1-0:31.4.0)
|
||||
assert isinstance(result.FUSE_THRESHOLD_L1, CosemObject)
|
||||
@ -336,7 +336,6 @@ class TelegramParserFluviusTest(unittest.TestCase):
|
||||
'INSTANTANEOUS_CURRENT_L3': {'value': 0.52, 'unit': 'A'},
|
||||
'ACTUAL_SWITCH_POSITION': {'value': 1, 'unit': None},
|
||||
'ACTUAL_TRESHOLD_ELECTRICITY': {'value': 999.9, 'unit': 'kW'},
|
||||
'BELGIUM_MAX_POWER_PER_PHASE': {'value': 999.9, 'unit': 'kW'},
|
||||
'FUSE_THRESHOLD_L1': {'value': 999.0, 'unit': 'A'},
|
||||
'TEXT_MESSAGE': {'value': None, 'unit': None},
|
||||
'BELGIUM_MBUS1_DEVICE_TYPE': {'value': 3, 'unit': None},
|
||||
@ -398,7 +397,6 @@ class TelegramParserFluviusTest(unittest.TestCase):
|
||||
'INSTANTANEOUS_CURRENT_L3: 0.52 [A]\n'
|
||||
'ACTUAL_SWITCH_POSITION: 1 [None]\n'
|
||||
'ACTUAL_TRESHOLD_ELECTRICITY: 999.9 [kW]\n'
|
||||
'BELGIUM_MAX_POWER_PER_PHASE: 999.9 [kW]\n'
|
||||
'FUSE_THRESHOLD_L1: 999 [A]\n'
|
||||
'TEXT_MESSAGE: None [None]\n'
|
||||
'BELGIUM_MBUS1_DEVICE_TYPE: 3 [None]\n'
|
||||
|