added basic config for DSMR v5 specification; added DSMR v5 example telegram for testing;
This commit is contained in:
parent
7a4c204850
commit
45ee8dbb32
@ -34,8 +34,9 @@ INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE = r'\d-\d:22\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE = r'\d-\d:42\.7\.0.+?\r\n'
|
||||
INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE = r'\d-\d:62\.7\.0.+?\r\n'
|
||||
EQUIPMENT_IDENTIFIER_GAS = r'\d-\d:96\.1\.0.+?\r\n'
|
||||
# TODO
|
||||
HOURLY_GAS_METER_READING = r'\d-\d:24\.2\.1.+?\r\n'
|
||||
GAS_METER_READING = r'\d-\d:24\.3\.0.+?\r\n.+?\r\n'
|
||||
GAS_METER_READING = r'(\d-\d:24\.3\.0.+?\r\n.+?\r\n)'
|
||||
ACTUAL_TRESHOLD_ELECTRICITY = r'\d-\d:17\.0\.0.+?\r\n'
|
||||
ACTUAL_SWITCH_POSITION = r'\d-\d:96\.3\.10.+?\r\n'
|
||||
VALVE_POSITION_GAS = r'\d-\d:24\.4\.0.+?\r\n'
|
||||
|
@ -15,7 +15,7 @@ how the telegram lines are parsed.
|
||||
|
||||
V2_2 = {
|
||||
'checksum_support': False,
|
||||
'objects': {
|
||||
'object_signatures': {
|
||||
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
||||
@ -47,12 +47,12 @@ V4 = {
|
||||
'objects': {
|
||||
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
||||
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
||||
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
|
||||
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
||||
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
||||
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
|
||||
@ -73,7 +73,46 @@ V4 = {
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
|
||||
obis.HOURLY_GAS_METER_READING: MBusParser(ValueParser(timestamp),
|
||||
ValueParser(Decimal))
|
||||
obis.HOURLY_GAS_METER_READING: MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
)
|
||||
}
|
||||
}
|
||||
|
||||
V5 = {
|
||||
'checksum_support': True,
|
||||
'objects': {
|
||||
obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
|
||||
obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
|
||||
obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||
obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
|
||||
obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
|
||||
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
||||
obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
|
||||
obis.LONG_POWER_FAILURE_COUNT: CosemParser(ValueParser(int)),
|
||||
# POWER_EVENT_FAILURE_LOG: ProfileGenericParser(), TODO
|
||||
obis.VOLTAGE_SAG_L1_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SAG_L2_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SAG_L3_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SWELL_L1_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SWELL_L2_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.VOLTAGE_SWELL_L3_COUNT: CosemParser(ValueParser(int)),
|
||||
obis.TEXT_MESSAGE: CosemParser(ValueParser(str)),
|
||||
obis.DEVICE_TYPE: CosemParser(ValueParser(int)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: CosemParser(ValueParser(Decimal)),
|
||||
obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)),
|
||||
obis.HOURLY_GAS_METER_READING: MBusParser(
|
||||
ValueParser(timestamp),
|
||||
ValueParser(Decimal)
|
||||
)
|
||||
}
|
||||
}
|
||||
|
@ -60,3 +60,46 @@ TELEGRAM_V4_2 = (
|
||||
'0-1:24.2.1(161129200000W)(00981.443*m3)\r\n'
|
||||
'!6796\r\n'
|
||||
)
|
||||
|
||||
TELEGRAM_V5 = (
|
||||
'/ISk5\2MT382-1000\r\n'
|
||||
'\r\n'
|
||||
'1-3:0.2.8(50)\r\n'
|
||||
'0-0:1.0.0(170102192002W)\r\n'
|
||||
'0-0:96.1.1(4B384547303034303436333935353037)\r\n'
|
||||
'1-0:1.8.1(000004.426*kWh)\r\n'
|
||||
'1-0:1.8.2(000002.399*kWh)\r\n'
|
||||
'1-0:2.8.1(000002.444*kWh)\r\n'
|
||||
'1-0:2.8.2(000000.000*kWh)\r\n'
|
||||
'0-0:96.14.0(0002)\r\n'
|
||||
'1-0:1.7.0(00.244*kW)\r\n'
|
||||
'1-0:2.7.0(00.000*kW)\r\n'
|
||||
'0-0:96.7.21(00013)\r\n'
|
||||
'0-0:96.7.9(00000)\r\n'
|
||||
'1-0:99.97.0(0)(0-0:96.7.19)\r\n'
|
||||
'1-0:32.32.0(00000)\r\n'
|
||||
'1-0:52.32.0(00000)\r\n'
|
||||
'1-0:72.32.0(00000)\r\n'
|
||||
'1-0:32.36.0(00000)\r\n'
|
||||
'1-0:52.36.0(00000)\r\n'
|
||||
'1-0:72.36.0(00000)\r\n'
|
||||
'0-0:96.13.0()\r\n'
|
||||
'1-0:32.7.0(0230.0*V)\r\n'
|
||||
'1-0:52.7.0(0230.0*V)\r\n'
|
||||
'1-0:72.7.0(0229.0*V)\r\n'
|
||||
'1-0:31.7.0(0.48*A)\r\n'
|
||||
'1-0:51.7.0(0.44*A)\r\n'
|
||||
'1-0:71.7.0(0.86*A)\r\n'
|
||||
'1-0:21.7.0(00.070*kW)\r\n'
|
||||
'1-0:41.7.0(00.032*kW)\r\n'
|
||||
'1-0:61.7.0(00.142*kW)\r\n'
|
||||
'1-0:22.7.0(00.000*kW)\r\n'
|
||||
'1-0:42.7.0(00.000*kW)\r\n'
|
||||
'1-0:62.7.0(00.000*kW)\r\n'
|
||||
'0-1:24.1.0(003)\r\n'
|
||||
'0-1:96.1.0(3232323241424344313233343536373839)\r\n'
|
||||
'0-1:24.2.1(170102161005W)(00000.107*m3)\r\n'
|
||||
'0-2:24.1.0(003)\r\n'
|
||||
'0-2:96.1.0()\r\n'
|
||||
'!87B3\r\n'
|
||||
)
|
||||
|
21
test/test_parse_v5.py
Normal file
21
test/test_parse_v5.py
Normal file
@ -0,0 +1,21 @@
|
||||
import unittest
|
||||
|
||||
from dsmr_parser import obis_references as obis
|
||||
from dsmr_parser import telegram_specifications
|
||||
from dsmr_parser.objects import CosemObject
|
||||
from dsmr_parser.parsers import TelegramParser
|
||||
from test.example_telegrams import TELEGRAM_V5
|
||||
|
||||
|
||||
class TelegramParserV5Test(unittest.TestCase):
|
||||
""" Test parsing of a DSMR v5.x telegram. """
|
||||
|
||||
def test_parse(self):
|
||||
parser = TelegramParser(telegram_specifications.V5)
|
||||
result = parser.parse(TELEGRAM_V5)
|
||||
|
||||
# P1_MESSAGE_HEADER (1-3:0.2.8)
|
||||
assert isinstance(result[obis.P1_MESSAGE_HEADER], CosemObject)
|
||||
assert result[obis.P1_MESSAGE_HEADER].unit is None
|
||||
assert isinstance(result[obis.P1_MESSAGE_HEADER].value, str)
|
||||
assert result[obis.P1_MESSAGE_HEADER].value == '50'
|