Change DSMR 5 and 5B to use DSMR devices
At least the BE and the NL DSMR devices use MBUS. Therefore we make the MBUS obis reference generic, and convert the V5 telegram to use MBUS values. Finally set self.maxDiff = None to have a full test output on some tests.
This commit is contained in:
parent
739419e3ee
commit
0e964def48
@ -69,8 +69,25 @@ ACTUAL_TRESHOLD_ELECTRICITY = r'^\d-\d:17\.0\.0.+?\r\n'
|
|||||||
ACTUAL_SWITCH_POSITION = r'^\d-\d:96\.3\.10.+?\r\n'
|
ACTUAL_SWITCH_POSITION = r'^\d-\d:96\.3\.10.+?\r\n'
|
||||||
VALVE_POSITION_GAS = r'^\d-\d:24\.4\.0.+?\r\n'
|
VALVE_POSITION_GAS = r'^\d-\d:24\.4\.0.+?\r\n'
|
||||||
|
|
||||||
|
# Multiple 'slaves' can be linked to the main device.
|
||||||
|
# The type is reported on 24.1.0
|
||||||
|
# Specifications are in EN 13757-3
|
||||||
|
# For example: Water mater = 7, Gas meter = 3
|
||||||
|
# Identifier is on 96.1.0 (in NL for ex) or
|
||||||
|
# on 96.1.1 (in BE for ex)
|
||||||
|
# The values are reported on 24.2.1
|
||||||
|
# With an exception in Belgium for the GAS meter
|
||||||
|
# Be aware that for the gas volume, another OBIS-code is published
|
||||||
|
# than the one listed in section 7 of DSMR P1.
|
||||||
|
# This is due to the fact that in Belgium the not-temperature
|
||||||
|
# corrected gas volume is used while in the Netherlands,
|
||||||
|
# the temperature corrected gas volume is used.
|
||||||
|
MBUS_DEVICE_TYPE = r'^\d-[1-9]:24\.1\.0.+?\r\n'
|
||||||
|
MBUS_EQUIPMENT_IDENTIFIER = r'^\d-[1-9]:96\.1\.[01].+?\r\n'
|
||||||
|
MBUS_VALVE_POSITION = r'^\d-[1-9]:24\.4\.0.+?\r\n'
|
||||||
|
MBUS_METER_READING = r'^\d-[1-9]:24\.2\.[13].+?\r\n'
|
||||||
|
|
||||||
# TODO 17.0.0
|
# TODO 17.0.0
|
||||||
# TODO 96.3.10
|
|
||||||
|
|
||||||
ELECTRICITY_USED_TARIFF_ALL = (
|
ELECTRICITY_USED_TARIFF_ALL = (
|
||||||
ELECTRICITY_USED_TARIFF_1,
|
ELECTRICITY_USED_TARIFF_1,
|
||||||
@ -92,36 +109,6 @@ BELGIUM_CURRENT_AVERAGE_DEMAND = r'^\d-\d:1\.4\.0.+?\r\n'
|
|||||||
BELGIUM_MAXIMUM_DEMAND_MONTH = r'^\d-\d:1\.6\.0.+?\r\n'
|
BELGIUM_MAXIMUM_DEMAND_MONTH = r'^\d-\d:1\.6\.0.+?\r\n'
|
||||||
BELGIUM_MAXIMUM_DEMAND_13_MONTHS = r'^\d-\d:98\.1\.0.+?\r\n'
|
BELGIUM_MAXIMUM_DEMAND_13_MONTHS = r'^\d-\d:98\.1\.0.+?\r\n'
|
||||||
|
|
||||||
# Multiple 'slaves' can be linked to the main device.
|
|
||||||
# Mostly MBUS1 = GAS METER with values on 24.2.3
|
|
||||||
# While WATER METER reports it's values on 24.2.1
|
|
||||||
# The GAS METER also reports its valve state on 24.4.0
|
|
||||||
# Dev type for gas = 7 and water = 8
|
|
||||||
BELGIUM_MBUS1_DEVICE_TYPE = r'^\d-1:24\.1\.0.+?\r\n'
|
|
||||||
BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER = r'^\d-1:96\.1\.1.+?\r\n'
|
|
||||||
BELGIUM_MBUS1_VALVE_POSITION = r'^\d-1:24\.4\.0.+?\r\n'
|
|
||||||
BELGIUM_MBUS1_METER_READING1 = r'^\d-1:24\.2\.1.+?\r\n'
|
|
||||||
BELGIUM_MBUS1_METER_READING2 = r'^\d-1:24\.2\.3.+?\r\n'
|
|
||||||
|
|
||||||
BELGIUM_MBUS2_DEVICE_TYPE = r'^\d-2:24\.1\.0.+?\r\n'
|
|
||||||
BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER = r'^\d-2:96\.1\.1.+?\r\n'
|
|
||||||
BELGIUM_MBUS2_VALVE_POSITION = r'^\d-2:24\.4\.0.+?\r\n'
|
|
||||||
BELGIUM_MBUS2_METER_READING1 = r'^\d-2:24\.2\.1.+?\r\n'
|
|
||||||
BELGIUM_MBUS2_METER_READING2 = r'^\d-2:24\.2\.3.+?\r\n'
|
|
||||||
|
|
||||||
BELGIUM_MBUS3_DEVICE_TYPE = r'^\d-3:24\.1\.0.+?\r\n'
|
|
||||||
BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER = r'^\d-3:96\.1\.1.+?\r\n'
|
|
||||||
BELGIUM_MBUS3_VALVE_POSITION = r'^\d-3:24\.4\.0.+?\r\n'
|
|
||||||
BELGIUM_MBUS3_METER_READING1 = r'^\d-3:24\.2\.1.+?\r\n'
|
|
||||||
BELGIUM_MBUS3_METER_READING2 = r'^\d-3:24\.2\.3.+?\r\n'
|
|
||||||
|
|
||||||
BELGIUM_MBUS4_DEVICE_TYPE = r'^\d-4:24\.1\.0.+?\r\n'
|
|
||||||
BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER = r'^\d-4:96\.1\.1.+?\r\n'
|
|
||||||
BELGIUM_MBUS4_VALVE_POSITION = r'^\d-4:24\.4\.0.+?\r\n'
|
|
||||||
BELGIUM_MBUS4_METER_READING1 = r'^\d-4:24\.2\.1.+?\r\n'
|
|
||||||
BELGIUM_MBUS4_METER_READING2 = r'^\d-4:24\.2\.3.+?\r\n'
|
|
||||||
|
|
||||||
|
|
||||||
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'^\d-\d:42\.0\.0.+?\r\n' # Logical device name
|
LUXEMBOURG_EQUIPMENT_IDENTIFIER = r'^\d-\d:42\.0\.0.+?\r\n' # Logical device name
|
||||||
|
|
||||||
Q3D_EQUIPMENT_IDENTIFIER = r'^\d-\d:0\.0\.0.+?\r\n' # Logical device name
|
Q3D_EQUIPMENT_IDENTIFIER = r'^\d-\d:0\.0\.0.+?\r\n' # Logical device name
|
||||||
|
@ -28,12 +28,12 @@ class Telegram(dict):
|
|||||||
def add(self, obis_reference, dsmr_object, obis_name):
|
def add(self, obis_reference, dsmr_object, obis_name):
|
||||||
# Update name mapping used to get value by attribute. Example: telegram.P1_MESSAGE_HEADER
|
# Update name mapping used to get value by attribute. Example: telegram.P1_MESSAGE_HEADER
|
||||||
setattr(self, obis_name, dsmr_object)
|
setattr(self, obis_name, dsmr_object)
|
||||||
if obis_name not in self._item_names: # TODO repeating obis references
|
|
||||||
self._item_names.append(obis_name)
|
|
||||||
|
|
||||||
# TODO isinstance check: MaxDemandParser (BELGIUM_MAXIMUM_DEMAND_13_MONTHS) returns a list
|
# TODO isinstance check: MaxDemandParser (BELGIUM_MAXIMUM_DEMAND_13_MONTHS) returns a list
|
||||||
if isinstance(dsmr_object, DSMRObject) and dsmr_object.is_mbus_reading:
|
if isinstance(dsmr_object, DSMRObject) and dsmr_object.is_mbus_reading:
|
||||||
self._add_mbus(obis_reference, dsmr_object, obis_name)
|
self._add_mbus(obis_reference, dsmr_object, obis_name)
|
||||||
|
elif obis_name not in self._item_names: # TODO repeating obis references
|
||||||
|
self._item_names.append(obis_name)
|
||||||
|
|
||||||
# Fill dict which is only used for backwards compatibility
|
# Fill dict which is only used for backwards compatibility
|
||||||
if obis_reference not in self:
|
if obis_reference not in self:
|
||||||
|
@ -430,11 +430,6 @@ V5 = {
|
|||||||
'value_parser': CosemParser(ValueParser(str)),
|
'value_parser': CosemParser(ValueParser(str)),
|
||||||
'value_name': 'TEXT_MESSAGE'
|
'value_name': 'TEXT_MESSAGE'
|
||||||
},
|
},
|
||||||
{
|
|
||||||
'obis_reference': obis.DEVICE_TYPE,
|
|
||||||
'value_parser': CosemParser(ValueParser(int)),
|
|
||||||
'value_name': 'DEVICE_TYPE'
|
|
||||||
},
|
|
||||||
{
|
{
|
||||||
'obis_reference': obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE,
|
'obis_reference': obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE,
|
||||||
'value_parser': CosemParser(ValueParser(Decimal)),
|
'value_parser': CosemParser(ValueParser(Decimal)),
|
||||||
@ -466,17 +461,27 @@ V5 = {
|
|||||||
'value_name': 'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE'
|
'value_name': 'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE'
|
||||||
},
|
},
|
||||||
{
|
{
|
||||||
'obis_reference': obis.EQUIPMENT_IDENTIFIER_GAS,
|
'obis_reference': obis.MBUS_DEVICE_TYPE,
|
||||||
'value_parser': CosemParser(ValueParser(str)),
|
'value_parser': CosemParser(ValueParser(int)),
|
||||||
'value_name': 'EQUIPMENT_IDENTIFIER_GAS'
|
'value_name': 'MBUS_DEVICE_TYPE'
|
||||||
},
|
},
|
||||||
{
|
{
|
||||||
'obis_reference': obis.HOURLY_GAS_METER_READING,
|
'obis_reference': obis.MBUS_EQUIPMENT_IDENTIFIER,
|
||||||
'value_parser': MBusParser(
|
'value_parser': CosemParser(ValueParser(str)),
|
||||||
|
'value_name': 'MBUS_EQUIPMENT_IDENTIFIER'
|
||||||
|
},
|
||||||
|
{
|
||||||
|
'obis_reference': obis.MBUS_VALVE_POSITION,
|
||||||
|
'value_parser': CosemParser(ValueParser(int)),
|
||||||
|
'value_name': 'MBUS_VALVE_POSITION'
|
||||||
|
},
|
||||||
|
{
|
||||||
|
'obis_reference': obis.MBUS_METER_READING,
|
||||||
|
'value_parser': MBusParser(
|
||||||
ValueParser(timestamp),
|
ValueParser(timestamp),
|
||||||
ValueParser(Decimal)
|
ValueParser(Decimal)
|
||||||
),
|
),
|
||||||
'value_name': 'HOURLY_GAS_METER_READING'
|
'value_name': 'MBUS_METER_READING'
|
||||||
},
|
},
|
||||||
]
|
]
|
||||||
}
|
}
|
||||||
@ -624,11 +629,6 @@ BELGIUM_FLUVIUS = {
|
|||||||
'value_parser': CosemParser(ValueParser(Decimal)),
|
'value_parser': CosemParser(ValueParser(Decimal)),
|
||||||
'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY'
|
'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY'
|
||||||
},
|
},
|
||||||
{
|
|
||||||
'obis_reference': obis.ACTUAL_TRESHOLD_ELECTRICITY,
|
|
||||||
'value_parser': CosemParser(ValueParser(Decimal)),
|
|
||||||
'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY'
|
|
||||||
},
|
|
||||||
{
|
{
|
||||||
'obis_reference': obis.FUSE_THRESHOLD_L1,
|
'obis_reference': obis.FUSE_THRESHOLD_L1,
|
||||||
'value_parser': CosemParser(ValueParser(Decimal)),
|
'value_parser': CosemParser(ValueParser(Decimal)),
|
||||||
@ -640,128 +640,27 @@ BELGIUM_FLUVIUS = {
|
|||||||
'value_name': 'TEXT_MESSAGE'
|
'value_name': 'TEXT_MESSAGE'
|
||||||
},
|
},
|
||||||
{
|
{
|
||||||
'obis_reference': obis.BELGIUM_MBUS1_DEVICE_TYPE,
|
'obis_reference': obis.MBUS_DEVICE_TYPE,
|
||||||
'value_parser': CosemParser(ValueParser(int)),
|
'value_parser': CosemParser(ValueParser(int)),
|
||||||
'value_name': 'BELGIUM_MBUS1_DEVICE_TYPE'
|
'value_name': 'MBUS_DEVICE_TYPE'
|
||||||
},
|
},
|
||||||
{
|
{
|
||||||
'obis_reference': obis.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER,
|
'obis_reference': obis.MBUS_EQUIPMENT_IDENTIFIER,
|
||||||
'value_parser': CosemParser(ValueParser(str)),
|
'value_parser': CosemParser(ValueParser(str)),
|
||||||
'value_name': 'BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER'
|
'value_name': 'MBUS_EQUIPMENT_IDENTIFIER'
|
||||||
},
|
},
|
||||||
{
|
{
|
||||||
'obis_reference': obis.BELGIUM_MBUS1_VALVE_POSITION,
|
'obis_reference': obis.MBUS_VALVE_POSITION,
|
||||||
'value_parser': CosemParser(ValueParser(int)),
|
'value_parser': CosemParser(ValueParser(int)),
|
||||||
'value_name': 'BELGIUM_MBUS1_VALVE_POSITION'
|
'value_name': 'MBUS_VALVE_POSITION'
|
||||||
},
|
},
|
||||||
{
|
{
|
||||||
'obis_reference': obis.BELGIUM_MBUS1_METER_READING1,
|
'obis_reference': obis.MBUS_METER_READING,
|
||||||
'value_parser': MBusParser(
|
'value_parser': MBusParser(
|
||||||
ValueParser(timestamp),
|
ValueParser(timestamp),
|
||||||
ValueParser(Decimal)
|
ValueParser(Decimal)
|
||||||
),
|
),
|
||||||
'value_name': 'BELGIUM_MBUS1_METER_READING1'
|
'value_name': 'MBUS_METER_READING'
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS1_METER_READING2,
|
|
||||||
'value_parser': MBusParser(
|
|
||||||
ValueParser(timestamp),
|
|
||||||
ValueParser(Decimal)
|
|
||||||
),
|
|
||||||
'value_name': 'BELGIUM_MBUS1_METER_READING2'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS2_DEVICE_TYPE,
|
|
||||||
'value_parser': CosemParser(ValueParser(int)),
|
|
||||||
'value_name': 'BELGIUM_MBUS2_DEVICE_TYPE'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER,
|
|
||||||
'value_parser': CosemParser(ValueParser(str)),
|
|
||||||
'value_name': 'BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS2_VALVE_POSITION,
|
|
||||||
'value_parser': CosemParser(ValueParser(int)),
|
|
||||||
'value_name': 'BELGIUM_MBUS2_VALVE_POSITION'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS2_METER_READING1,
|
|
||||||
'value_parser': MBusParser(
|
|
||||||
ValueParser(timestamp),
|
|
||||||
ValueParser(Decimal)
|
|
||||||
),
|
|
||||||
'value_name': 'BELGIUM_MBUS2_METER_READING1'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS2_METER_READING2,
|
|
||||||
'value_parser': MBusParser(
|
|
||||||
ValueParser(timestamp),
|
|
||||||
ValueParser(Decimal)
|
|
||||||
),
|
|
||||||
'value_name': 'BELGIUM_MBUS2_METER_READING2'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS3_DEVICE_TYPE,
|
|
||||||
'value_parser': CosemParser(ValueParser(int)),
|
|
||||||
'value_name': 'BELGIUM_MBUS3_DEVICE_TYPE'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER,
|
|
||||||
'value_parser': CosemParser(ValueParser(str)),
|
|
||||||
'value_name': 'BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS3_VALVE_POSITION,
|
|
||||||
'value_parser': CosemParser(ValueParser(int)),
|
|
||||||
'value_name': 'BELGIUM_MBUS3_VALVE_POSITION'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS3_METER_READING1,
|
|
||||||
'value_parser': MBusParser(
|
|
||||||
ValueParser(timestamp),
|
|
||||||
ValueParser(Decimal)
|
|
||||||
),
|
|
||||||
'value_name': 'BELGIUM_MBUS3_METER_READING1'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS3_METER_READING2,
|
|
||||||
'value_parser': MBusParser(
|
|
||||||
ValueParser(timestamp),
|
|
||||||
ValueParser(Decimal)
|
|
||||||
),
|
|
||||||
'value_name': 'BELGIUM_MBUS3_METER_READING2'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS4_DEVICE_TYPE,
|
|
||||||
'value_parser': CosemParser(ValueParser(int)),
|
|
||||||
'value_name': 'BELGIUM_MBUS4_DEVICE_TYPE'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER,
|
|
||||||
'value_parser': CosemParser(ValueParser(str)),
|
|
||||||
'value_name': 'BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS4_VALVE_POSITION,
|
|
||||||
'value_parser': CosemParser(ValueParser(int)),
|
|
||||||
'value_name': 'BELGIUM_MBUS4_VALVE_POSITION'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS4_METER_READING1,
|
|
||||||
'value_parser': MBusParser(
|
|
||||||
ValueParser(timestamp),
|
|
||||||
ValueParser(Decimal)
|
|
||||||
),
|
|
||||||
'value_name': 'BELGIUM_MBUS4_METER_READING1'
|
|
||||||
},
|
|
||||||
{
|
|
||||||
'obis_reference': obis.BELGIUM_MBUS4_METER_READING2,
|
|
||||||
'value_parser': MBusParser(
|
|
||||||
ValueParser(timestamp),
|
|
||||||
ValueParser(Decimal)
|
|
||||||
),
|
|
||||||
'value_name': 'BELGIUM_MBUS4_METER_READING2'
|
|
||||||
},
|
},
|
||||||
]
|
]
|
||||||
}
|
}
|
||||||
|
@ -15,59 +15,59 @@ class MbusDeviceTest(unittest.TestCase):
|
|||||||
device_type_parser = [
|
device_type_parser = [
|
||||||
object["value_parser"]
|
object["value_parser"]
|
||||||
for object in v5_objects
|
for object in v5_objects
|
||||||
if object["obis_reference"] == obis_references.DEVICE_TYPE
|
if object["obis_reference"] == obis_references.MBUS_DEVICE_TYPE
|
||||||
][0]
|
][0]
|
||||||
device_type = device_type_parser.parse('0-2:24.1.0(003)\r\n')
|
device_type = device_type_parser.parse('0-2:24.1.0(003)\r\n')
|
||||||
|
|
||||||
equipment_parser = [
|
equipment_parser = [
|
||||||
object["value_parser"]
|
object["value_parser"]
|
||||||
for object in v5_objects
|
for object in v5_objects
|
||||||
if object["obis_reference"] == obis_references.EQUIPMENT_IDENTIFIER_GAS
|
if object["obis_reference"] == obis_references.MBUS_EQUIPMENT_IDENTIFIER
|
||||||
][0]
|
][0]
|
||||||
equipment = equipment_parser.parse('0-2:96.1.0(4730303339303031393336393930363139)\r\n')
|
equipment = equipment_parser.parse('0-2:96.1.0(4730303339303031393336393930363139)\r\n')
|
||||||
|
|
||||||
gas_reading_parser = [
|
gas_reading_parser = [
|
||||||
object["value_parser"]
|
object["value_parser"]
|
||||||
for object in v5_objects
|
for object in v5_objects
|
||||||
if object["obis_reference"] == obis_references.HOURLY_GAS_METER_READING
|
if object["obis_reference"] == obis_references.MBUS_METER_READING
|
||||||
][0]
|
][0]
|
||||||
gas_reading = gas_reading_parser.parse('0-2:24.2.1(200426223001S)(00246.138*m3)\r\n')
|
gas_reading = gas_reading_parser.parse('0-2:24.2.1(200426223001S)(00246.138*m3)\r\n')
|
||||||
|
|
||||||
mbus_device = MbusDevice(channel_id=1)
|
mbus_device = MbusDevice(channel_id=2)
|
||||||
mbus_device.add(obis_references.DEVICE_TYPE, device_type, "DEVICE_TYPE")
|
mbus_device.add(obis_references.MBUS_DEVICE_TYPE, device_type, "MBUS_DEVICE_TYPE")
|
||||||
mbus_device.add(obis_references.EQUIPMENT_IDENTIFIER_GAS, equipment, "EQUIPMENT_IDENTIFIER_GAS")
|
mbus_device.add(obis_references.MBUS_EQUIPMENT_IDENTIFIER, equipment, "MBUS_EQUIPMENT_IDENTIFIER")
|
||||||
mbus_device.add(obis_references.HOURLY_GAS_METER_READING, gas_reading, "HOURLY_GAS_METER_READING")
|
mbus_device.add(obis_references.MBUS_METER_READING, gas_reading, "MBUS_METER_READING")
|
||||||
|
|
||||||
self.mbus_device = mbus_device
|
self.mbus_device = mbus_device
|
||||||
|
|
||||||
def test_attributes(self):
|
def test_attributes(self):
|
||||||
self.assertEqual(self.mbus_device.DEVICE_TYPE.value, 3)
|
self.assertEqual(self.mbus_device.MBUS_DEVICE_TYPE.value, 3)
|
||||||
self.assertEqual(self.mbus_device.DEVICE_TYPE.unit, None)
|
self.assertEqual(self.mbus_device.MBUS_DEVICE_TYPE.unit, None)
|
||||||
|
|
||||||
self.assertEqual(self.mbus_device.EQUIPMENT_IDENTIFIER_GAS.value,
|
self.assertEqual(self.mbus_device.MBUS_EQUIPMENT_IDENTIFIER.value,
|
||||||
'4730303339303031393336393930363139')
|
'4730303339303031393336393930363139')
|
||||||
self.assertEqual(self.mbus_device.EQUIPMENT_IDENTIFIER_GAS.unit, None)
|
self.assertEqual(self.mbus_device.MBUS_EQUIPMENT_IDENTIFIER.unit, None)
|
||||||
|
|
||||||
self.assertEqual(self.mbus_device.HOURLY_GAS_METER_READING.value, Decimal('246.138'))
|
self.assertEqual(self.mbus_device.MBUS_METER_READING.value, Decimal('246.138'))
|
||||||
self.assertEqual(self.mbus_device.HOURLY_GAS_METER_READING.unit, 'm3')
|
self.assertEqual(self.mbus_device.MBUS_METER_READING.unit, 'm3')
|
||||||
|
|
||||||
def test_to_json(self):
|
def test_to_json(self):
|
||||||
self.assertEqual(
|
self.assertEqual(
|
||||||
json.loads(self.mbus_device.to_json()),
|
json.loads(self.mbus_device.to_json()),
|
||||||
{
|
{
|
||||||
'CHANNEL_ID': 1,
|
'CHANNEL_ID': 2,
|
||||||
'DEVICE_TYPE': {'value': 3, 'unit': None},
|
'MBUS_DEVICE_TYPE': {'value': 3, 'unit': None},
|
||||||
'EQUIPMENT_IDENTIFIER_GAS': {'value': '4730303339303031393336393930363139', 'unit': None},
|
'MBUS_EQUIPMENT_IDENTIFIER': {'value': '4730303339303031393336393930363139', 'unit': None},
|
||||||
'HOURLY_GAS_METER_READING': {'datetime': '2020-04-26T20:30:01+00:00', 'value': 246.138, 'unit': 'm3'}}
|
'MBUS_METER_READING': {'datetime': '2020-04-26T20:30:01+00:00', 'value': 246.138, 'unit': 'm3'}}
|
||||||
)
|
)
|
||||||
|
|
||||||
def test_str(self):
|
def test_str(self):
|
||||||
self.assertEqual(
|
self.assertEqual(
|
||||||
str(self.mbus_device),
|
str(self.mbus_device),
|
||||||
(
|
(
|
||||||
'MBUS DEVICE (channel 1)\n'
|
'MBUS DEVICE (channel 2)\n'
|
||||||
'\tDEVICE_TYPE: 3 [None]\n'
|
'\tMBUS_DEVICE_TYPE: 3 [None]\n'
|
||||||
'\tEQUIPMENT_IDENTIFIER_GAS: 4730303339303031393336393930363139 [None]\n'
|
'\tMBUS_EQUIPMENT_IDENTIFIER: 4730303339303031393336393930363139 [None]\n'
|
||||||
'\tHOURLY_GAS_METER_READING: 246.138 [m3] at 2020-04-26T20:30:01+00:00\n'
|
'\tMBUS_METER_READING: 246.138 [m3] at 2020-04-26T20:30:01+00:00\n'
|
||||||
)
|
)
|
||||||
)
|
)
|
||||||
|
@ -216,14 +216,6 @@ class TelegramTest(unittest.TestCase):
|
|||||||
value_type=Decimal,
|
value_type=Decimal,
|
||||||
value_val=Decimal('2'))
|
value_val=Decimal('2'))
|
||||||
|
|
||||||
# DEVICE_TYPE (0-x:24.1.0)
|
|
||||||
self.verify_telegram_item(telegram,
|
|
||||||
'DEVICE_TYPE',
|
|
||||||
object_type=CosemObject,
|
|
||||||
unit_val=None,
|
|
||||||
value_type=int,
|
|
||||||
value_val=3)
|
|
||||||
|
|
||||||
# INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE (1-0:21.7.0)
|
# INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE (1-0:21.7.0)
|
||||||
self.verify_telegram_item(telegram,
|
self.verify_telegram_item(telegram,
|
||||||
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE',
|
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE',
|
||||||
@ -272,7 +264,15 @@ class TelegramTest(unittest.TestCase):
|
|||||||
value_type=Decimal,
|
value_type=Decimal,
|
||||||
value_val=Decimal('0'))
|
value_val=Decimal('0'))
|
||||||
|
|
||||||
# EQUIPMENT_IDENTIFIER_GAS (0-x:96.1.0)
|
# DEVICE_TYPE (0-1:24.1.0)
|
||||||
|
self.verify_telegram_item(telegram,
|
||||||
|
'DEVICE_TYPE',
|
||||||
|
object_type=CosemObject,
|
||||||
|
unit_val=None,
|
||||||
|
value_type=int,
|
||||||
|
value_val=3)
|
||||||
|
|
||||||
|
# EQUIPMENT_IDENTIFIER_GAS (0-1:96.1.0)
|
||||||
self.verify_telegram_item(telegram,
|
self.verify_telegram_item(telegram,
|
||||||
'EQUIPMENT_IDENTIFIER_GAS',
|
'EQUIPMENT_IDENTIFIER_GAS',
|
||||||
object_type=CosemObject,
|
object_type=CosemObject,
|
||||||
@ -340,28 +340,28 @@ class TelegramTest(unittest.TestCase):
|
|||||||
self.assertEqual(len(mbus_devices), 2)
|
self.assertEqual(len(mbus_devices), 2)
|
||||||
|
|
||||||
mbus_device_1 = mbus_devices[0]
|
mbus_device_1 = mbus_devices[0]
|
||||||
self.assertEqual(mbus_device_1.DEVICE_TYPE.value, 3)
|
self.assertEqual(mbus_device_1.MBUS_DEVICE_TYPE.value, 3)
|
||||||
self.assertEqual(mbus_device_1.EQUIPMENT_IDENTIFIER_GAS.value, None)
|
self.assertEqual(mbus_device_1.MBUS_EQUIPMENT_IDENTIFIER.value, None)
|
||||||
self.assertEqual(mbus_device_1.HOURLY_GAS_METER_READING.value, Decimal('0'))
|
self.assertEqual(mbus_device_1.MBUS_METER_READING.value, Decimal('0'))
|
||||||
|
|
||||||
mbus_device_2 = mbus_devices[1]
|
mbus_device_2 = mbus_devices[1]
|
||||||
self.assertEqual(mbus_device_2.DEVICE_TYPE.value, 3)
|
self.assertEqual(mbus_device_2.MBUS_DEVICE_TYPE.value, 3)
|
||||||
self.assertEqual(mbus_device_2.EQUIPMENT_IDENTIFIER_GAS.value, '4730303339303031393336393930363139')
|
self.assertEqual(mbus_device_2.MBUS_EQUIPMENT_IDENTIFIER.value, '4730303339303031393336393930363139')
|
||||||
self.assertEqual(mbus_device_2.HOURLY_GAS_METER_READING.value, Decimal('246.138'))
|
self.assertEqual(mbus_device_2.MBUS_METER_READING.value, Decimal('246.138'))
|
||||||
|
|
||||||
def test_get_mbus_device_by_channel(self):
|
def test_get_mbus_device_by_channel(self):
|
||||||
parser = TelegramParser(telegram_specifications.V5)
|
parser = TelegramParser(telegram_specifications.V5)
|
||||||
telegram = parser.parse(TELEGRAM_V5_TWO_MBUS)
|
telegram = parser.parse(TELEGRAM_V5_TWO_MBUS)
|
||||||
|
|
||||||
mbus_device_1 = telegram.get_mbus_device_by_channel(1)
|
mbus_device_1 = telegram.get_mbus_device_by_channel(1)
|
||||||
self.assertEqual(mbus_device_1.DEVICE_TYPE.value, 3)
|
self.assertEqual(mbus_device_1.MBUS_DEVICE_TYPE.value, 3)
|
||||||
self.assertEqual(mbus_device_1.EQUIPMENT_IDENTIFIER_GAS.value, None)
|
self.assertEqual(mbus_device_1.MBUS_EQUIPMENT_IDENTIFIER.value, None)
|
||||||
self.assertEqual(mbus_device_1.HOURLY_GAS_METER_READING.value, Decimal('0'))
|
self.assertEqual(mbus_device_1.MBUS_METER_READING.value, Decimal('0'))
|
||||||
|
|
||||||
mbus_device_2 = telegram.get_mbus_device_by_channel(2)
|
mbus_device_2 = telegram.get_mbus_device_by_channel(2)
|
||||||
self.assertEqual(mbus_device_2.DEVICE_TYPE.value, 3)
|
self.assertEqual(mbus_device_2.MBUS_DEVICE_TYPE.value, 3)
|
||||||
self.assertEqual(mbus_device_2.EQUIPMENT_IDENTIFIER_GAS.value, '4730303339303031393336393930363139')
|
self.assertEqual(mbus_device_2.MBUS_EQUIPMENT_IDENTIFIER.value, '4730303339303031393336393930363139')
|
||||||
self.assertEqual(mbus_device_2.HOURLY_GAS_METER_READING.value, Decimal('246.138'))
|
self.assertEqual(mbus_device_2.MBUS_METER_READING.value, Decimal('246.138'))
|
||||||
|
|
||||||
def test_without_mbus_devices(self):
|
def test_without_mbus_devices(self):
|
||||||
parser = TelegramParser(telegram_specifications.V5, apply_checksum_validation=False)
|
parser = TelegramParser(telegram_specifications.V5, apply_checksum_validation=False)
|
||||||
@ -375,11 +375,12 @@ class TelegramTest(unittest.TestCase):
|
|||||||
telegram = parser.parse(TELEGRAM_V5)
|
telegram = parser.parse(TELEGRAM_V5)
|
||||||
json_data = json.loads(telegram.to_json())
|
json_data = json.loads(telegram.to_json())
|
||||||
|
|
||||||
|
self.maxDiff = None
|
||||||
|
|
||||||
self.assertEqual(
|
self.assertEqual(
|
||||||
json_data,
|
json_data,
|
||||||
{'CURRENT_ELECTRICITY_DELIVERY': {'unit': 'kW', 'value': 0.0},
|
{'CURRENT_ELECTRICITY_DELIVERY': {'unit': 'kW', 'value': 0.0},
|
||||||
'CURRENT_ELECTRICITY_USAGE': {'unit': 'kW', 'value': 0.244},
|
'CURRENT_ELECTRICITY_USAGE': {'unit': 'kW', 'value': 0.244},
|
||||||
'DEVICE_TYPE': {'unit': None, 'value': 3},
|
|
||||||
'ELECTRICITY_ACTIVE_TARIFF': {'unit': None, 'value': '0002'},
|
'ELECTRICITY_ACTIVE_TARIFF': {'unit': None, 'value': '0002'},
|
||||||
'ELECTRICITY_DELIVERED_TARIFF_1': {'unit': 'kWh', 'value': 2.444},
|
'ELECTRICITY_DELIVERED_TARIFF_1': {'unit': 'kWh', 'value': 2.444},
|
||||||
'ELECTRICITY_DELIVERED_TARIFF_2': {'unit': 'kWh', 'value': 0.0},
|
'ELECTRICITY_DELIVERED_TARIFF_2': {'unit': 'kWh', 'value': 0.0},
|
||||||
@ -387,10 +388,6 @@ class TelegramTest(unittest.TestCase):
|
|||||||
'ELECTRICITY_USED_TARIFF_2': {'unit': 'kWh', 'value': 2.399},
|
'ELECTRICITY_USED_TARIFF_2': {'unit': 'kWh', 'value': 2.399},
|
||||||
'EQUIPMENT_IDENTIFIER': {'unit': None,
|
'EQUIPMENT_IDENTIFIER': {'unit': None,
|
||||||
'value': '4B384547303034303436333935353037'},
|
'value': '4B384547303034303436333935353037'},
|
||||||
'EQUIPMENT_IDENTIFIER_GAS': {'unit': None, 'value': None},
|
|
||||||
'HOURLY_GAS_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00',
|
|
||||||
'unit': 'm3',
|
|
||||||
'value': 0.107},
|
|
||||||
'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE': {'unit': 'kW', 'value': 0.0},
|
'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE': {'unit': 'kW', 'value': 0.0},
|
||||||
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE': {'unit': 'kW', 'value': 0.07},
|
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE': {'unit': 'kW', 'value': 0.07},
|
||||||
'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE': {'unit': 'kW', 'value': 0.0},
|
'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE': {'unit': 'kW', 'value': 0.0},
|
||||||
@ -405,15 +402,16 @@ class TelegramTest(unittest.TestCase):
|
|||||||
'INSTANTANEOUS_VOLTAGE_L3': {'unit': 'V', 'value': 229.0},
|
'INSTANTANEOUS_VOLTAGE_L3': {'unit': 'V', 'value': 229.0},
|
||||||
'LONG_POWER_FAILURE_COUNT': {'unit': None, 'value': 0},
|
'LONG_POWER_FAILURE_COUNT': {'unit': None, 'value': 0},
|
||||||
'MBUS_DEVICES': [{'CHANNEL_ID': 1,
|
'MBUS_DEVICES': [{'CHANNEL_ID': 1,
|
||||||
'DEVICE_TYPE': {'unit': None, 'value': 3},
|
'MBUS_DEVICE_TYPE': {'unit': None, 'value': 3},
|
||||||
'EQUIPMENT_IDENTIFIER_GAS': {'unit': None,
|
'MBUS_EQUIPMENT_IDENTIFIER': {'unit': None,
|
||||||
'value': '3232323241424344313233343536373839'},
|
'value': '3232323241424344313233343536373839'},
|
||||||
'HOURLY_GAS_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00',
|
'MBUS_METER_READING': {'datetime': '2017-01-02T15:10:05+00:00',
|
||||||
'unit': 'm3',
|
'unit': 'm3',
|
||||||
'value': 0.107}},
|
'value': 0.107}},
|
||||||
{'CHANNEL_ID': 2,
|
{'CHANNEL_ID': 2,
|
||||||
'DEVICE_TYPE': {'unit': None, 'value': 3},
|
'MBUS_DEVICE_TYPE': {'unit': None, 'value': 3},
|
||||||
'EQUIPMENT_IDENTIFIER_GAS': {'unit': None, 'value': None}}],
|
'MBUS_EQUIPMENT_IDENTIFIER': {'unit': None,
|
||||||
|
'value': None}}],
|
||||||
'P1_MESSAGE_HEADER': {'unit': None, 'value': '50'},
|
'P1_MESSAGE_HEADER': {'unit': None, 'value': '50'},
|
||||||
'P1_MESSAGE_TIMESTAMP': {'unit': None, 'value': '2017-01-02T18:20:02+00:00'},
|
'P1_MESSAGE_TIMESTAMP': {'unit': None, 'value': '2017-01-02T18:20:02+00:00'},
|
||||||
'POWER_EVENT_FAILURE_LOG': {'buffer': [],
|
'POWER_EVENT_FAILURE_LOG': {'buffer': [],
|
||||||
@ -433,6 +431,8 @@ class TelegramTest(unittest.TestCase):
|
|||||||
parser = TelegramParser(telegram_specifications.V5)
|
parser = TelegramParser(telegram_specifications.V5)
|
||||||
telegram = parser.parse(TELEGRAM_V5)
|
telegram = parser.parse(TELEGRAM_V5)
|
||||||
|
|
||||||
|
self.maxDiff = None
|
||||||
|
|
||||||
self.assertEqual(
|
self.assertEqual(
|
||||||
str(telegram),
|
str(telegram),
|
||||||
(
|
(
|
||||||
@ -463,22 +463,19 @@ class TelegramTest(unittest.TestCase):
|
|||||||
'INSTANTANEOUS_CURRENT_L2: 0.44 [A]\n'
|
'INSTANTANEOUS_CURRENT_L2: 0.44 [A]\n'
|
||||||
'INSTANTANEOUS_CURRENT_L3: 0.86 [A]\n'
|
'INSTANTANEOUS_CURRENT_L3: 0.86 [A]\n'
|
||||||
'TEXT_MESSAGE: None [None]\n'
|
'TEXT_MESSAGE: None [None]\n'
|
||||||
'DEVICE_TYPE: 3 [None]\n'
|
|
||||||
'MBUS DEVICE (channel 1)\n'
|
|
||||||
' DEVICE_TYPE: 3 [None]\n'
|
|
||||||
' EQUIPMENT_IDENTIFIER_GAS: 3232323241424344313233343536373839 [None]\n'
|
|
||||||
' HOURLY_GAS_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n'
|
|
||||||
'MBUS DEVICE (channel 2)\n'
|
|
||||||
' DEVICE_TYPE: 3 [None]\n'
|
|
||||||
' EQUIPMENT_IDENTIFIER_GAS: None [None]\n'
|
|
||||||
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: 0.070 [kW]\n'
|
'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: 0.070 [kW]\n'
|
||||||
'INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: 0.032 [kW]\n'
|
'INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: 0.032 [kW]\n'
|
||||||
'INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: 0.142 [kW]\n'
|
'INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: 0.142 [kW]\n'
|
||||||
'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: 0.000 [kW]\n'
|
'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: 0.000 [kW]\n'
|
||||||
'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: 0.000 [kW]\n'
|
'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: 0.000 [kW]\n'
|
||||||
'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: 0.000 [kW]\n'
|
'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: 0.000 [kW]\n'
|
||||||
'EQUIPMENT_IDENTIFIER_GAS: None [None]\n'
|
'MBUS DEVICE (channel 1)\n'
|
||||||
'HOURLY_GAS_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n'
|
' MBUS_DEVICE_TYPE: 3 [None]\n'
|
||||||
|
' MBUS_EQUIPMENT_IDENTIFIER: 3232323241424344313233343536373839 [None]\n'
|
||||||
|
' MBUS_METER_READING: 0.107 [m3] at 2017-01-02T15:10:05+00:00\n'
|
||||||
|
'MBUS DEVICE (channel 2)\n'
|
||||||
|
' MBUS_DEVICE_TYPE: 3 [None]\n'
|
||||||
|
' MBUS_EQUIPMENT_IDENTIFIER: None [None]\n'
|
||||||
)
|
)
|
||||||
)
|
)
|
||||||
|
|
||||||
|
@ -228,47 +228,53 @@ class TelegramParserFluviusTest(unittest.TestCase):
|
|||||||
assert result.TEXT_MESSAGE.unit is None
|
assert result.TEXT_MESSAGE.unit is None
|
||||||
assert result.TEXT_MESSAGE.value is None
|
assert result.TEXT_MESSAGE.value is None
|
||||||
|
|
||||||
# BELGIUM_MBUS1_DEVICE_TYPE (0-1:24.1.0)
|
# MBUS DEVICE 1
|
||||||
assert isinstance(result.BELGIUM_MBUS1_DEVICE_TYPE, CosemObject)
|
mbus1 = result.get_mbus_device_by_channel(1)
|
||||||
assert result.BELGIUM_MBUS1_DEVICE_TYPE.unit is None
|
|
||||||
assert isinstance(result.BELGIUM_MBUS1_DEVICE_TYPE.value, int)
|
|
||||||
assert result.BELGIUM_MBUS1_DEVICE_TYPE.value == 3
|
|
||||||
|
|
||||||
# BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER (0-1:96.1.1)
|
# MBUS_DEVICE_TYPE (0-1:24.1.0)
|
||||||
assert isinstance(result.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER, CosemObject)
|
assert isinstance(mbus1.MBUS_DEVICE_TYPE, CosemObject)
|
||||||
assert result.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER.unit is None
|
assert mbus1.MBUS_DEVICE_TYPE.unit is None
|
||||||
assert isinstance(result.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER.value, str)
|
assert isinstance(mbus1.MBUS_DEVICE_TYPE.value, int)
|
||||||
assert result.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER.value == '37464C4F32313139303333373333'
|
assert mbus1.MBUS_DEVICE_TYPE.value == 3
|
||||||
|
|
||||||
# BELGIUM_MBUS1_VALVE_POSITION (0-1:24.4.0)
|
# MBUS_EQUIPMENT_IDENTIFIER (0-1:96.1.1)
|
||||||
assert isinstance(result.BELGIUM_MBUS1_VALVE_POSITION, CosemObject)
|
assert isinstance(mbus1.MBUS_EQUIPMENT_IDENTIFIER, CosemObject)
|
||||||
assert result.BELGIUM_MBUS1_VALVE_POSITION.unit is None
|
assert mbus1.MBUS_EQUIPMENT_IDENTIFIER.unit is None
|
||||||
assert isinstance(result.BELGIUM_MBUS1_VALVE_POSITION.value, int)
|
assert isinstance(mbus1.MBUS_EQUIPMENT_IDENTIFIER.value, str)
|
||||||
assert result.BELGIUM_MBUS1_VALVE_POSITION.value == 1
|
assert mbus1.MBUS_EQUIPMENT_IDENTIFIER.value == '37464C4F32313139303333373333'
|
||||||
|
|
||||||
# BELGIUM_MBUS1_METER_READING2 (0-1:24.2.3)
|
# MBUS_VALVE_POSITION (0-1:24.4.0)
|
||||||
assert isinstance(result.BELGIUM_MBUS1_METER_READING2, MBusObject)
|
assert isinstance(result.MBUS_VALVE_POSITION, CosemObject)
|
||||||
assert result.BELGIUM_MBUS1_METER_READING2.unit == 'm3'
|
assert result.MBUS_VALVE_POSITION.unit is None
|
||||||
assert isinstance(result.BELGIUM_MBUS1_METER_READING2.value, Decimal)
|
assert isinstance(result.MBUS_VALVE_POSITION.value, int)
|
||||||
assert result.BELGIUM_MBUS1_METER_READING2.value == Decimal('112.384')
|
assert result.MBUS_VALVE_POSITION.value == 1
|
||||||
|
|
||||||
# BELGIUM_MBUS2_DEVICE_TYPE (0-2:24.1.0)
|
# MBUS_METER_READING (0-1:24.2.3)
|
||||||
assert isinstance(result.BELGIUM_MBUS2_DEVICE_TYPE, CosemObject)
|
assert isinstance(mbus1.MBUS_METER_READING, MBusObject)
|
||||||
assert result.BELGIUM_MBUS2_DEVICE_TYPE.unit is None
|
assert mbus1.MBUS_METER_READING.unit == 'm3'
|
||||||
assert isinstance(result.BELGIUM_MBUS2_DEVICE_TYPE.value, int)
|
assert isinstance(mbus1.MBUS_METER_READING.value, Decimal)
|
||||||
assert result.BELGIUM_MBUS2_DEVICE_TYPE.value == 7
|
assert mbus1.MBUS_METER_READING.value == Decimal('112.384')
|
||||||
|
|
||||||
# BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER (0-2:96.1.1)
|
# MBUS DEVICE 2
|
||||||
assert isinstance(result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER, CosemObject)
|
mbus2 = result.get_mbus_device_by_channel(2)
|
||||||
assert result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER.unit is None
|
|
||||||
assert isinstance(result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER.value, str)
|
|
||||||
assert result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER.value == '3853414731323334353637383930'
|
|
||||||
|
|
||||||
# BELGIUM_MBUS2_METER_READING1 (0-1:24.2.1)
|
# MBUS_DEVICE_TYPE (0-2:24.1.0)
|
||||||
assert isinstance(result.BELGIUM_MBUS2_METER_READING1, MBusObject)
|
assert isinstance(mbus2.MBUS_DEVICE_TYPE, CosemObject)
|
||||||
assert result.BELGIUM_MBUS2_METER_READING1.unit == 'm3'
|
assert mbus2.MBUS_DEVICE_TYPE.unit is None
|
||||||
assert isinstance(result.BELGIUM_MBUS2_METER_READING1.value, Decimal)
|
assert isinstance(mbus2.MBUS_DEVICE_TYPE.value, int)
|
||||||
assert result.BELGIUM_MBUS2_METER_READING1.value == Decimal('872.234')
|
assert mbus2.MBUS_DEVICE_TYPE.value == 7
|
||||||
|
|
||||||
|
# MBUS_EQUIPMENT_IDENTIFIER (0-2:96.1.1)
|
||||||
|
assert isinstance(mbus2.MBUS_EQUIPMENT_IDENTIFIER, CosemObject)
|
||||||
|
assert mbus2.MBUS_EQUIPMENT_IDENTIFIER.unit is None
|
||||||
|
assert isinstance(mbus2.MBUS_EQUIPMENT_IDENTIFIER.value, str)
|
||||||
|
assert mbus2.MBUS_EQUIPMENT_IDENTIFIER.value == '3853414731323334353637383930'
|
||||||
|
|
||||||
|
# MBUS_METER_READING (0-1:24.2.1)
|
||||||
|
assert isinstance(mbus2.MBUS_METER_READING, MBusObject)
|
||||||
|
assert mbus2.MBUS_METER_READING.unit == 'm3'
|
||||||
|
assert isinstance(mbus2.MBUS_METER_READING.value, Decimal)
|
||||||
|
assert mbus2.MBUS_METER_READING.value == Decimal('872.234')
|
||||||
|
|
||||||
def test_checksum_valid(self):
|
def test_checksum_valid(self):
|
||||||
# No exception is raised.
|
# No exception is raised.
|
||||||
@ -296,6 +302,8 @@ class TelegramParserFluviusTest(unittest.TestCase):
|
|||||||
telegram = parser.parse(TELEGRAM_FLUVIUS_V171_ALT)
|
telegram = parser.parse(TELEGRAM_FLUVIUS_V171_ALT)
|
||||||
json_data = json.loads(telegram.to_json())
|
json_data = json.loads(telegram.to_json())
|
||||||
|
|
||||||
|
self.maxDiff = None
|
||||||
|
|
||||||
self.assertEqual(
|
self.assertEqual(
|
||||||
json_data,
|
json_data,
|
||||||
{'BELGIUM_VERSION_INFORMATION': {'value': '50217', 'unit': None},
|
{'BELGIUM_VERSION_INFORMATION': {'value': '50217', 'unit': None},
|
||||||
@ -338,26 +346,19 @@ class TelegramParserFluviusTest(unittest.TestCase):
|
|||||||
'ACTUAL_TRESHOLD_ELECTRICITY': {'value': 999.9, 'unit': 'kW'},
|
'ACTUAL_TRESHOLD_ELECTRICITY': {'value': 999.9, 'unit': 'kW'},
|
||||||
'FUSE_THRESHOLD_L1': {'value': 999.0, 'unit': 'A'},
|
'FUSE_THRESHOLD_L1': {'value': 999.0, 'unit': 'A'},
|
||||||
'TEXT_MESSAGE': {'value': None, 'unit': None},
|
'TEXT_MESSAGE': {'value': None, 'unit': None},
|
||||||
'BELGIUM_MBUS1_DEVICE_TYPE': {'value': 3, 'unit': None},
|
'MBUS_DEVICES': [{'MBUS_DEVICE_TYPE': {'value': 3, 'unit': None},
|
||||||
'MBUS_DEVICES': [{'BELGIUM_MBUS1_DEVICE_TYPE': {'value': 3, 'unit': None},
|
'MBUS_EQUIPMENT_IDENTIFIER': {'value': '37464C4F32313233303838303237',
|
||||||
'BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER': {'value': '37464C4F32313233303838303237',
|
|
||||||
'unit': None},
|
'unit': None},
|
||||||
'BELGIUM_MBUS1_VALVE_POSITION': {'value': 1, 'unit': None},
|
'MBUS_VALVE_POSITION': {'value': 1, 'unit': None},
|
||||||
'BELGIUM_MBUS1_METER_READING2': {'datetime': '2023-11-02T11:10:02+00:00',
|
'MBUS_METER_READING': {'datetime': '2023-11-02T11:10:02+00:00',
|
||||||
'value': 92.287, 'unit': 'm3'},
|
'value': 92.287, 'unit': 'm3'},
|
||||||
'CHANNEL_ID': 1},
|
'CHANNEL_ID': 1},
|
||||||
{'BELGIUM_MBUS2_DEVICE_TYPE': {'value': 7, 'unit': None},
|
{'MBUS_DEVICE_TYPE': {'value': 7, 'unit': None},
|
||||||
'BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER': {'value': '3853455430303030393631313733',
|
'MBUS_EQUIPMENT_IDENTIFIER': {'value': '3853455430303030393631313733',
|
||||||
'unit': None},
|
'unit': None},
|
||||||
'BELGIUM_MBUS2_METER_READING1': {'datetime': '2023-11-02T11:15:32+00:00',
|
'MBUS_METER_READING': {'datetime': '2023-11-02T11:15:32+00:00',
|
||||||
'value': 8.579, 'unit': 'm3'},
|
'value': 8.579, 'unit': 'm3'},
|
||||||
'CHANNEL_ID': 2}],
|
'CHANNEL_ID': 2}]}
|
||||||
'BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER': {'value': '37464C4F32313233303838303237', 'unit': None},
|
|
||||||
'BELGIUM_MBUS1_VALVE_POSITION': {'value': 1, 'unit': None},
|
|
||||||
'BELGIUM_MBUS1_METER_READING2': {'datetime': '2023-11-02T11:10:02+00:00', 'value': 92.287, 'unit': 'm3'},
|
|
||||||
'BELGIUM_MBUS2_DEVICE_TYPE': {'value': 7, 'unit': None},
|
|
||||||
'BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER': {'value': '3853455430303030393631313733', 'unit': None},
|
|
||||||
'BELGIUM_MBUS2_METER_READING1': {'datetime': '2023-11-02T11:15:32+00:00', 'value': 8.579, 'unit': 'm3'}}
|
|
||||||
)
|
)
|
||||||
|
|
||||||
def test_to_str(self):
|
def test_to_str(self):
|
||||||
@ -399,21 +400,14 @@ class TelegramParserFluviusTest(unittest.TestCase):
|
|||||||
'ACTUAL_TRESHOLD_ELECTRICITY: 999.9 [kW]\n'
|
'ACTUAL_TRESHOLD_ELECTRICITY: 999.9 [kW]\n'
|
||||||
'FUSE_THRESHOLD_L1: 999 [A]\n'
|
'FUSE_THRESHOLD_L1: 999 [A]\n'
|
||||||
'TEXT_MESSAGE: None [None]\n'
|
'TEXT_MESSAGE: None [None]\n'
|
||||||
'BELGIUM_MBUS1_DEVICE_TYPE: 3 [None]\n'
|
|
||||||
'MBUS DEVICE (channel 1)\n'
|
'MBUS DEVICE (channel 1)\n'
|
||||||
' BELGIUM_MBUS1_DEVICE_TYPE: 3 [None]\n'
|
' MBUS_DEVICE_TYPE: 3 [None]\n'
|
||||||
' BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER: 37464C4F32313233303838303237 [None]\n'
|
' MBUS_EQUIPMENT_IDENTIFIER: 37464C4F32313233303838303237 [None]\n'
|
||||||
' BELGIUM_MBUS1_VALVE_POSITION: 1 [None]\n'
|
' MBUS_VALVE_POSITION: 1 [None]\n'
|
||||||
' BELGIUM_MBUS1_METER_READING2: 92.287 [m3] at 2023-11-02T11:10:02+00:00\n'
|
' MBUS_METER_READING: 92.287 [m3] at 2023-11-02T11:10:02+00:00\n'
|
||||||
'MBUS DEVICE (channel 2)\n'
|
'MBUS DEVICE (channel 2)\n'
|
||||||
' BELGIUM_MBUS2_DEVICE_TYPE: 7 [None]\n'
|
' MBUS_DEVICE_TYPE: 7 [None]\n'
|
||||||
' BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER: 3853455430303030393631313733 [None]\n'
|
' MBUS_EQUIPMENT_IDENTIFIER: 3853455430303030393631313733 [None]\n'
|
||||||
' BELGIUM_MBUS2_METER_READING1: 8.579 [m3] at 2023-11-02T11:15:32+00:00\n'
|
' MBUS_METER_READING: 8.579 [m3] at 2023-11-02T11:15:32+00:00\n'
|
||||||
'BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER: 37464C4F32313233303838303237 [None]\n'
|
|
||||||
'BELGIUM_MBUS1_VALVE_POSITION: 1 [None]\n'
|
|
||||||
'BELGIUM_MBUS1_METER_READING2: 92.287 [m3] at 2023-11-02T11:10:02+00:00\n'
|
|
||||||
'BELGIUM_MBUS2_DEVICE_TYPE: 7 [None]\n'
|
|
||||||
'BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER: 3853455430303030393631313733 [None]\n'
|
|
||||||
'BELGIUM_MBUS2_METER_READING1: 8.579 [m3] at 2023-11-02T11:15:32+00:00\n'
|
|
||||||
)
|
)
|
||||||
)
|
)
|
||||||
|
@ -172,12 +172,6 @@ class TelegramParserV5Test(unittest.TestCase):
|
|||||||
assert telegram.TEXT_MESSAGE.unit is None
|
assert telegram.TEXT_MESSAGE.unit is None
|
||||||
assert telegram.TEXT_MESSAGE.value is None
|
assert telegram.TEXT_MESSAGE.value is None
|
||||||
|
|
||||||
# DEVICE_TYPE (0-x:24.1.0)
|
|
||||||
assert isinstance(telegram.DEVICE_TYPE, CosemObject)
|
|
||||||
assert telegram.DEVICE_TYPE.unit is None
|
|
||||||
assert isinstance(telegram.DEVICE_TYPE.value, int)
|
|
||||||
assert telegram.DEVICE_TYPE.value == 3
|
|
||||||
|
|
||||||
# INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE (1-0:21.7.0)
|
# INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE (1-0:21.7.0)
|
||||||
assert isinstance(telegram.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE, CosemObject)
|
assert isinstance(telegram.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE, CosemObject)
|
||||||
assert telegram.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE.unit == 'kW'
|
assert telegram.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE.unit == 'kW'
|
||||||
@ -215,27 +209,27 @@ class TelegramParserV5Test(unittest.TestCase):
|
|||||||
assert telegram.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE.value == Decimal('0')
|
assert telegram.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE.value == Decimal('0')
|
||||||
|
|
||||||
# There's only one Mbus device (gas meter) in this case. Alternatively
|
# There's only one Mbus device (gas meter) in this case. Alternatively
|
||||||
# use get_mbget_mbus_device_by_channel
|
# use get_mbus_device_by_channel
|
||||||
gas_meter_devices = telegram.MBUS_DEVICES
|
gas_meter_devices = telegram.MBUS_DEVICES
|
||||||
gas_meter_device = gas_meter_devices[0]
|
gas_meter_device = gas_meter_devices[0]
|
||||||
|
|
||||||
# EQUIPMENT_IDENTIFIER_GAS (0-x:96.1.0)
|
# MBUS_DEVICE_TYPE (0-1:96.1.0)
|
||||||
assert isinstance(gas_meter_device.DEVICE_TYPE, CosemObject)
|
assert isinstance(gas_meter_device.MBUS_DEVICE_TYPE, CosemObject)
|
||||||
assert gas_meter_device.DEVICE_TYPE.unit is None
|
assert gas_meter_device.MBUS_DEVICE_TYPE.unit is None
|
||||||
assert isinstance(gas_meter_device.DEVICE_TYPE.value, int)
|
assert isinstance(gas_meter_device.MBUS_DEVICE_TYPE.value, int)
|
||||||
assert gas_meter_device.DEVICE_TYPE.value == 3
|
assert gas_meter_device.MBUS_DEVICE_TYPE.value == 3
|
||||||
|
|
||||||
# EQUIPMENT_IDENTIFIER_GAS (0-x:96.1.0)
|
# MBUS_EQUIPMENT_IDENTIFIER (0-1:96.1.0)
|
||||||
assert isinstance(gas_meter_device.EQUIPMENT_IDENTIFIER_GAS, CosemObject)
|
assert isinstance(gas_meter_device.MBUS_EQUIPMENT_IDENTIFIER, CosemObject)
|
||||||
assert gas_meter_device.EQUIPMENT_IDENTIFIER_GAS.unit is None
|
assert gas_meter_device.MBUS_EQUIPMENT_IDENTIFIER.unit is None
|
||||||
assert isinstance(gas_meter_device.EQUIPMENT_IDENTIFIER_GAS.value, str)
|
assert isinstance(gas_meter_device.MBUS_EQUIPMENT_IDENTIFIER.value, str)
|
||||||
assert gas_meter_device.EQUIPMENT_IDENTIFIER_GAS.value == '3232323241424344313233343536373839'
|
assert gas_meter_device.MBUS_EQUIPMENT_IDENTIFIER.value == '3232323241424344313233343536373839'
|
||||||
|
|
||||||
# HOURLY_GAS_METER_READING (0-1:24.2.1)
|
# MBUS_METER_READING (0-1:24.2.1)
|
||||||
assert isinstance(gas_meter_device.HOURLY_GAS_METER_READING, MBusObject)
|
assert isinstance(gas_meter_device.MBUS_METER_READING, MBusObject)
|
||||||
assert gas_meter_device.HOURLY_GAS_METER_READING.unit == 'm3'
|
assert gas_meter_device.MBUS_METER_READING.unit == 'm3'
|
||||||
assert isinstance(telegram.HOURLY_GAS_METER_READING.value, Decimal)
|
assert isinstance(telegram.MBUS_METER_READING.value, Decimal)
|
||||||
assert gas_meter_device.HOURLY_GAS_METER_READING.value == Decimal('0.107')
|
assert gas_meter_device.MBUS_METER_READING.value == Decimal('0.107')
|
||||||
|
|
||||||
def test_checksum_valid(self):
|
def test_checksum_valid(self):
|
||||||
# No exception is raised.
|
# No exception is raised.
|
||||||
@ -270,8 +264,11 @@ class TelegramParserV5Test(unittest.TestCase):
|
|||||||
parser = TelegramParser(telegram_specifications.V5)
|
parser = TelegramParser(telegram_specifications.V5)
|
||||||
telegram = parser.parse(invalid_date_telegram)
|
telegram = parser.parse(invalid_date_telegram)
|
||||||
|
|
||||||
# HOURLY_GAS_METER_READING (0-1:24.2.1)
|
# MBUS DEVICE 1
|
||||||
assert isinstance(telegram.HOURLY_GAS_METER_READING, MBusObject)
|
mbus1 = telegram.get_mbus_device_by_channel(1)
|
||||||
assert telegram.HOURLY_GAS_METER_READING.unit is None
|
|
||||||
assert isinstance(telegram.HOURLY_GAS_METER_READING.value, Decimal)
|
# MBUS_METER_READING (0-1:24.2.1)
|
||||||
assert telegram.HOURLY_GAS_METER_READING.value == Decimal('0.000')
|
assert isinstance(mbus1.MBUS_METER_READING, MBusObject)
|
||||||
|
assert mbus1.MBUS_METER_READING.unit is None
|
||||||
|
assert isinstance(mbus1.MBUS_METER_READING.value, Decimal)
|
||||||
|
assert mbus1.MBUS_METER_READING.value == Decimal('0.000')
|
||||||
|
Loading…
Reference in New Issue
Block a user