diff --git a/dsmr_parser/obis_name_mapping.py b/dsmr_parser/obis_name_mapping.py
index 95f1016..f8a94e1 100644
--- a/dsmr_parser/obis_name_mapping.py
+++ b/dsmr_parser/obis_name_mapping.py
@@ -1,120 +1,122 @@
 from dsmr_parser import obis_references as obis
 
-"""
+'''
 dsmr_parser.obis_name_mapping
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
 This module contains a mapping of obis references to names.
-"""
+'''
 
 EN = {
-    obis.P1_MESSAGE_HEADER: 'P1_MESSAGE_HEADER',
-    obis.P1_MESSAGE_TIMESTAMP: 'P1_MESSAGE_TIMESTAMP',
-    obis.ELECTRICITY_IMPORTED_TOTAL: 'ELECTRICITY_IMPORTED_TOTAL',
-    obis.ELECTRICITY_REACTIVE_IMPORTED_TOTAL: 'ELECTRICITY_REACTIVE_IMPORTED_TOTAL',
-    obis.ELECTRICITY_USED_TARIFF_1: 'ELECTRICITY_USED_TARIFF_1',
-    obis.ELECTRICITY_USED_TARIFF_2: 'ELECTRICITY_USED_TARIFF_2',
-    obis.ELECTRICITY_EXPORTED_TOTAL: 'ELECTRICITY_EXPORTED_TOTAL',
-    obis.ELECTRICITY_REACTIVE_EXPORTED_TOTAL: 'ELECTRICITY_REACTIVE_EXPORTED_TOTAL',
-    obis.ELECTRICITY_DELIVERED_TARIFF_1: 'ELECTRICITY_DELIVERED_TARIFF_1',
-    obis.ELECTRICITY_DELIVERED_TARIFF_2: 'ELECTRICITY_DELIVERED_TARIFF_2',
-    obis.ELECTRICITY_ACTIVE_TARIFF: 'ELECTRICITY_ACTIVE_TARIFF',
-    obis.CURRENT_REACTIVE_EXPORTED: 'CURRENT_REACTIVE_EXPORTED',
-    obis.ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1: 'ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1',
-    obis.ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2: 'ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2',
-    obis.ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1: 'ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1',
-    obis.ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2: 'ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2',
-    obis.CURRENT_REACTIVE_IMPORTED: 'CURRENT_REACTIVE_IMPORTED',
-    obis.EQUIPMENT_IDENTIFIER: 'EQUIPMENT_IDENTIFIER',
-    obis.CURRENT_ELECTRICITY_USAGE: 'CURRENT_ELECTRICITY_USAGE',
-    obis.CURRENT_ELECTRICITY_DELIVERY: 'CURRENT_ELECTRICITY_DELIVERY',
-    obis.LONG_POWER_FAILURE_COUNT: 'LONG_POWER_FAILURE_COUNT',
-    obis.SHORT_POWER_FAILURE_COUNT: 'SHORT_POWER_FAILURE_COUNT',
-    obis.POWER_EVENT_FAILURE_LOG: 'POWER_EVENT_FAILURE_LOG',
-    obis.VOLTAGE_SAG_L1_COUNT: 'VOLTAGE_SAG_L1_COUNT',
-    obis.VOLTAGE_SAG_L2_COUNT: 'VOLTAGE_SAG_L2_COUNT',
-    obis.VOLTAGE_SAG_L3_COUNT: 'VOLTAGE_SAG_L3_COUNT',
-    obis.VOLTAGE_SWELL_L1_COUNT: 'VOLTAGE_SWELL_L1_COUNT',
-    obis.VOLTAGE_SWELL_L2_COUNT: 'VOLTAGE_SWELL_L2_COUNT',
-    obis.VOLTAGE_SWELL_L3_COUNT: 'VOLTAGE_SWELL_L3_COUNT',
-    obis.INSTANTANEOUS_VOLTAGE_L1: 'INSTANTANEOUS_VOLTAGE_L1',
-    obis.INSTANTANEOUS_VOLTAGE_L2: 'INSTANTANEOUS_VOLTAGE_L2',
-    obis.INSTANTANEOUS_VOLTAGE_L3: 'INSTANTANEOUS_VOLTAGE_L3',
-    obis.INSTANTANEOUS_CURRENT_L1: 'INSTANTANEOUS_CURRENT_L1',
-    obis.INSTANTANEOUS_CURRENT_L2: 'INSTANTANEOUS_CURRENT_L2',
-    obis.INSTANTANEOUS_CURRENT_L3: 'INSTANTANEOUS_CURRENT_L3',
-    obis.TEXT_MESSAGE_CODE: 'TEXT_MESSAGE_CODE',
-    obis.TEXT_MESSAGE: 'TEXT_MESSAGE',
-    obis.DEVICE_TYPE: 'DEVICE_TYPE',
-    obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: 'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE',
-    obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: 'INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE',
-    obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: 'INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE',
-    obis.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE: 'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE',
-    obis.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE: 'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE',
-    obis.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE: 'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE',
-    obis.INSTANTANEOUS_REACTIVE_POWER_L1_POSITIVE: 'INSTANTANEOUS_REACTIVE_POWER_L1_POSITIVE',
-    obis.INSTANTANEOUS_REACTIVE_POWER_L1_NEGATIVE: 'INSTANTANEOUS_REACTIVE_POWER_L1_NEGATIVE',
-    obis.INSTANTANEOUS_REACTIVE_POWER_L2_POSITIVE: 'INSTANTANEOUS_REACTIVE_POWER_L2_POSITIVE',
-    obis.INSTANTANEOUS_REACTIVE_POWER_L2_NEGATIVE: 'INSTANTANEOUS_REACTIVE_POWER_L2_NEGATIVE',
-    obis.INSTANTANEOUS_REACTIVE_POWER_L3_POSITIVE: 'INSTANTANEOUS_REACTIVE_POWER_L3_POSITIVE',
-    obis.INSTANTANEOUS_REACTIVE_POWER_L3_NEGATIVE: 'INSTANTANEOUS_REACTIVE_POWER_L3_NEGATIVE',
-    obis.EQUIPMENT_IDENTIFIER_GAS: 'EQUIPMENT_IDENTIFIER_GAS',
-    obis.HOURLY_GAS_METER_READING: 'HOURLY_GAS_METER_READING',
-    obis.GAS_METER_READING: 'GAS_METER_READING',
-    obis.ACTUAL_TRESHOLD_ELECTRICITY: 'ACTUAL_TRESHOLD_ELECTRICITY',
-    obis.ACTUAL_SWITCH_POSITION: 'ACTUAL_SWITCH_POSITION',
-    obis.VALVE_POSITION_GAS: 'VALVE_POSITION_GAS',
-    obis.BELGIUM_VERSION_INFORMATION: 'BELGIUM_VERSION_INFORMATION',
-    obis.BELGIUM_EQUIPMENT_IDENTIFIER: 'BELGIUM_EQUIPMENT_IDENTIFIER',
-    obis.BELGIUM_CURRENT_AVERAGE_DEMAND: 'BELGIUM_CURRENT_AVERAGE_DEMAND',
-    obis.BELGIUM_MAXIMUM_DEMAND_MONTH: 'BELGIUM_MAXIMUM_DEMAND_MONTH',
-    obis.BELGIUM_MAXIMUM_DEMAND_13_MONTHS: 'BELGIUM_MAXIMUM_DEMAND_13_MONTHS',
-    obis.BELGIUM_MAX_POWER_PER_PHASE: 'BELGIUM_MAX_POWER_PER_PHASE',
-    obis.BELGIUM_MAX_CURRENT_PER_PHASE: 'BELGIUM_MAX_CURRENT_PER_PHASE',
-    obis.BELGIUM_MBUS1_DEVICE_TYPE: 'BELGIUM_MBUS1_DEVICE_TYPE',
-    obis.BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER: 'BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER',
-    obis.BELGIUM_MBUS1_VALVE_POSITION: 'BELGIUM_MBUS1_VALVE_POSITION',
-    obis.BELGIUM_MBUS1_METER_READING1: 'BELGIUM_MBUS1_METER_READING1',
-    obis.BELGIUM_MBUS1_METER_READING2: 'BELGIUM_MBUS1_METER_READING2',
-    obis.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER: 'BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER',
-    obis.BELGIUM_MBUS2_VALVE_POSITION: 'BELGIUM_MBUS2_VALVE_POSITION',
-    obis.BELGIUM_MBUS2_METER_READING1: 'BELGIUM_MBUS2_METER_READING1',
-    obis.BELGIUM_MBUS2_METER_READING2: 'BELGIUM_MBUS2_METER_READING2',
-    obis.BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER: 'BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER',
-    obis.BELGIUM_MBUS3_VALVE_POSITION: 'BELGIUM_MBUS3_VALVE_POSITION',
-    obis.BELGIUM_MBUS3_METER_READING1: 'BELGIUM_MBUS3_METER_READING1',
-    obis.BELGIUM_MBUS3_METER_READING2: 'BELGIUM_MBUS3_METER_READING2',
-    obis.BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER: 'BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER',
-    obis.BELGIUM_MBUS4_VALVE_POSITION: 'BELGIUM_MBUS4_VALVE_POSITION',
-    obis.BELGIUM_MBUS4_METER_READING1: 'BELGIUM_MBUS4_METER_READING1',
-    obis.BELGIUM_MBUS4_METER_READING2: 'BELGIUM_MBUS4_METER_READING2',
-    obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: 'LUXEMBOURG_EQUIPMENT_IDENTIFIER',
-    obis.Q3D_EQUIPMENT_IDENTIFIER: 'Q3D_EQUIPMENT_IDENTIFIER',
-    obis.Q3D_EQUIPMENT_STATE: 'Q3D_EQUIPMENT_STATE',
-    obis.Q3D_EQUIPMENT_SERIALNUMBER: 'Q3D_EQUIPMENT_SERIALNUMBER',
-    obis.BELGIUM_MBUS2_DEVICE_TYPE: 'BELGIUM_MBUS2_DEVICE_TYPE',
-    obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_3: 'EON_HU_ELECTRICITY_DELIVERED_TARIFF_3',
-    obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_4: 'EON_HU_ELECTRICITY_DELIVERED_TARIFF_4',
-    obis.EON_HU_ELECTRICITY_USED_TARIFF_3: 'EON_HU_ELECTRICITY_USED_TARIFF_3',
-    obis.EON_HU_ELECTRICITY_USED_TARIFF_4: 'EON_HU_ELECTRICITY_USED_TARIFF_4',
-    obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q1: 'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q1',
-    obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q2: 'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q2',
-    obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q3: 'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q3',
-    obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q4: 'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q4',
-    obis.EON_HU_ELECTRICITY_COMBINED: 'EON_HU_ELECTRICITY_COMBINED',
-    obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_TOTAL: 'EON_HU_INSTANTANEOUS_POWER_FACTOR_TOTAL',
-    obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L1: 'EON_HU_INSTANTANEOUS_POWER_FACTOR_L1',
-    obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L2: 'EON_HU_INSTANTANEOUS_POWER_FACTOR_L2',
-    obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L3: 'EON_HU_INSTANTANEOUS_POWER_FACTOR_L3',
-    obis.EON_HU_FREQUENCY: 'EON_HU_FREQUENCY',
-    obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q1: 'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q1',
-    obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q2: 'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q2',
-    obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3: 'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3',
-    obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4: 'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4',
-    obis.EON_HU_MAX_POWER_ON_L1: 'EON_HU_MAX_POWER_ON_L1',
-    obis.EON_HU_MAX_POWER_ON_L2: 'EON_HU_MAX_POWER_ON_L2',
-    obis.EON_HU_MAX_POWER_ON_L3: 'EON_HU_MAX_POWER_ON_L3',
-    obis.EON_HU_LAST_MONTH_DATA: 'EON_HU_LAST_MONTH_DATA'
+    'P1_MESSAGE_HEADER': 'P1_MESSAGE_HEADER',
+    'P1_MESSAGE_TIMESTAMP': 'P1_MESSAGE_TIMESTAMP',
+    'ELECTRICITY_IMPORTED_TOTAL': 'ELECTRICITY_IMPORTED_TOTAL',
+    'ELECTRICITY_REACTIVE_IMPORTED_TOTAL': 'ELECTRICITY_REACTIVE_IMPORTED_TOTAL',
+    'ELECTRICITY_USED_TARIFF_1': 'ELECTRICITY_USED_TARIFF_1',
+    'ELECTRICITY_USED_TARIFF_2': 'ELECTRICITY_USED_TARIFF_2',
+    'ELECTRICITY_EXPORTED_TOTAL': 'ELECTRICITY_EXPORTED_TOTAL',
+    'ELECTRICITY_REACTIVE_EXPORTED_TOTAL': 'ELECTRICITY_REACTIVE_EXPORTED_TOTAL',
+    'ELECTRICITY_DELIVERED_TARIFF_1': 'ELECTRICITY_DELIVERED_TARIFF_1',
+    'ELECTRICITY_DELIVERED_TARIFF_2': 'ELECTRICITY_DELIVERED_TARIFF_2',
+    'ELECTRICITY_ACTIVE_TARIFF': 'ELECTRICITY_ACTIVE_TARIFF',
+    'CURRENT_REACTIVE_EXPORTED': 'CURRENT_REACTIVE_EXPORTED',
+    'ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1': 'ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1',
+    'ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2': 'ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2',
+    'ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1': 'ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1',
+    'ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2': 'ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2',
+    'CURRENT_REACTIVE_IMPORTED': 'CURRENT_REACTIVE_IMPORTED',
+    'EQUIPMENT_IDENTIFIER': 'EQUIPMENT_IDENTIFIER',
+    'CURRENT_ELECTRICITY_USAGE': 'CURRENT_ELECTRICITY_USAGE',
+    'CURRENT_ELECTRICITY_DELIVERY': 'CURRENT_ELECTRICITY_DELIVERY',
+    'LONG_POWER_FAILURE_COUNT': 'LONG_POWER_FAILURE_COUNT',
+    'SHORT_POWER_FAILURE_COUNT': 'SHORT_POWER_FAILURE_COUNT',
+    'POWER_EVENT_FAILURE_LOG': 'POWER_EVENT_FAILURE_LOG',
+    'VOLTAGE_SAG_L1_COUNT': 'VOLTAGE_SAG_L1_COUNT',
+    'VOLTAGE_SAG_L2_COUNT': 'VOLTAGE_SAG_L2_COUNT',
+    'VOLTAGE_SAG_L3_COUNT': 'VOLTAGE_SAG_L3_COUNT',
+    'VOLTAGE_SWELL_L1_COUNT': 'VOLTAGE_SWELL_L1_COUNT',
+    'VOLTAGE_SWELL_L2_COUNT': 'VOLTAGE_SWELL_L2_COUNT',
+    'VOLTAGE_SWELL_L3_COUNT': 'VOLTAGE_SWELL_L3_COUNT',
+    'INSTANTANEOUS_VOLTAGE_L1': 'INSTANTANEOUS_VOLTAGE_L1',
+    'INSTANTANEOUS_VOLTAGE_L2': 'INSTANTANEOUS_VOLTAGE_L2',
+    'INSTANTANEOUS_VOLTAGE_L3': 'INSTANTANEOUS_VOLTAGE_L3',
+    'INSTANTANEOUS_CURRENT_L1': 'INSTANTANEOUS_CURRENT_L1',
+    'INSTANTANEOUS_CURRENT_L2': 'INSTANTANEOUS_CURRENT_L2',
+    'INSTANTANEOUS_CURRENT_L3': 'INSTANTANEOUS_CURRENT_L3',
+    'TEXT_MESSAGE_CODE': 'TEXT_MESSAGE_CODE',
+    'TEXT_MESSAGE': 'TEXT_MESSAGE',
+    'DEVICE_TYPE': 'DEVICE_TYPE',
+    'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE': 'INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE',
+    'INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE': 'INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE',
+    'INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE': 'INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE',
+    'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE': 'INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE',
+    'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE': 'INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE',
+    'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE': 'INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE',
+    'INSTANTANEOUS_REACTIVE_POWER_L1_POSITIVE': 'INSTANTANEOUS_REACTIVE_POWER_L1_POSITIVE',
+    'INSTANTANEOUS_REACTIVE_POWER_L1_NEGATIVE': 'INSTANTANEOUS_REACTIVE_POWER_L1_NEGATIVE',
+    'INSTANTANEOUS_REACTIVE_POWER_L2_POSITIVE': 'INSTANTANEOUS_REACTIVE_POWER_L2_POSITIVE',
+    'INSTANTANEOUS_REACTIVE_POWER_L2_NEGATIVE': 'INSTANTANEOUS_REACTIVE_POWER_L2_NEGATIVE',
+    'INSTANTANEOUS_REACTIVE_POWER_L3_POSITIVE': 'INSTANTANEOUS_REACTIVE_POWER_L3_POSITIVE',
+    'INSTANTANEOUS_REACTIVE_POWER_L3_NEGATIVE': 'INSTANTANEOUS_REACTIVE_POWER_L3_NEGATIVE',
+    'EQUIPMENT_IDENTIFIER_GAS': 'EQUIPMENT_IDENTIFIER_GAS',
+    'HOURLY_GAS_METER_READING': 'HOURLY_GAS_METER_READING',
+    'GAS_METER_READING': 'GAS_METER_READING',
+    'ACTUAL_TRESHOLD_ELECTRICITY': 'ACTUAL_TRESHOLD_ELECTRICITY',
+    'ACTUAL_SWITCH_POSITION': 'ACTUAL_SWITCH_POSITION',
+    'VALVE_POSITION_GAS': 'VALVE_POSITION_GAS',
+    'BELGIUM_VERSION_INFORMATION': 'BELGIUM_VERSION_INFORMATION',
+    'BELGIUM_EQUIPMENT_IDENTIFIER': 'BELGIUM_EQUIPMENT_IDENTIFIER',
+    'BELGIUM_CURRENT_AVERAGE_DEMAND': 'BELGIUM_CURRENT_AVERAGE_DEMAND',
+    'BELGIUM_MAXIMUM_DEMAND_MONTH': 'BELGIUM_MAXIMUM_DEMAND_MONTH',
+    'BELGIUM_MAXIMUM_DEMAND_13_MONTHS': 'BELGIUM_MAXIMUM_DEMAND_13_MONTHS',
+    'BELGIUM_MAX_POWER_PER_PHASE': 'BELGIUM_MAX_POWER_PER_PHASE',
+    'BELGIUM_MAX_CURRENT_PER_PHASE': 'BELGIUM_MAX_CURRENT_PER_PHASE',
+    'BELGIUM_MBUS1_DEVICE_TYPE': 'BELGIUM_MBUS1_DEVICE_TYPE',
+    'BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER': 'BELGIUM_MBUS1_EQUIPMENT_IDENTIFIER',
+    'BELGIUM_MBUS1_VALVE_POSITION': 'BELGIUM_MBUS1_VALVE_POSITION',
+    'BELGIUM_MBUS1_METER_READING1': 'BELGIUM_MBUS1_METER_READING1',
+    'BELGIUM_MBUS1_METER_READING2': 'BELGIUM_MBUS1_METER_READING2',
+    'BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER': 'BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER',
+    'BELGIUM_MBUS2_VALVE_POSITION': 'BELGIUM_MBUS2_VALVE_POSITION',
+    'BELGIUM_MBUS2_METER_READING1': 'BELGIUM_MBUS2_METER_READING1',
+    'BELGIUM_MBUS2_METER_READING2': 'BELGIUM_MBUS2_METER_READING2',
+    'BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER': 'BELGIUM_MBUS3_EQUIPMENT_IDENTIFIER',
+    'BELGIUM_MBUS3_VALVE_POSITION': 'BELGIUM_MBUS3_VALVE_POSITION',
+    'BELGIUM_MBUS3_METER_READING1': 'BELGIUM_MBUS3_METER_READING1',
+    'BELGIUM_MBUS3_METER_READING2': 'BELGIUM_MBUS3_METER_READING2',
+    'BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER': 'BELGIUM_MBUS4_EQUIPMENT_IDENTIFIER',
+    'BELGIUM_MBUS4_VALVE_POSITION': 'BELGIUM_MBUS4_VALVE_POSITION',
+    'BELGIUM_MBUS4_METER_READING1': 'BELGIUM_MBUS4_METER_READING1',
+    'BELGIUM_MBUS4_METER_READING2': 'BELGIUM_MBUS4_METER_READING2',
+    'LUXEMBOURG_EQUIPMENT_IDENTIFIER': 'LUXEMBOURG_EQUIPMENT_IDENTIFIER',
+    'Q3D_EQUIPMENT_IDENTIFIER': 'Q3D_EQUIPMENT_IDENTIFIER',
+    'Q3D_EQUIPMENT_STATE': 'Q3D_EQUIPMENT_STATE',
+    'Q3D_EQUIPMENT_SERIALNUMBER': 'Q3D_EQUIPMENT_SERIALNUMBER',
+    'BELGIUM_MBUS2_DEVICE_TYPE': 'BELGIUM_MBUS2_DEVICE_TYPE',
+	'EON_HU_COSEM_LOGICAL_DEVICE_NAME': 'COSEM_LOGICAL_DEVICE_NAME',
+	'EON_HU_EQUIPMENT_SERIAL_NUMBER': 'EQUIPMENT_SERIAL_NUMBER',
+    'EON_HU_ELECTRICITY_DELIVERED_TARIFF_3': 'ELECTRICITY_DELIVERED_TARIFF_3',
+    'EON_HU_ELECTRICITY_DELIVERED_TARIFF_4': 'ELECTRICITY_DELIVERED_TARIFF_4',
+    'EON_HU_ELECTRICITY_USED_TARIFF_3': 'ELECTRICITY_USED_TARIFF_3',
+    'EON_HU_ELECTRICITY_USED_TARIFF_4': 'ELECTRICITY_USED_TARIFF_4',
+    'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q1': 'ELECTRICITY_REACTIVE_TOTAL_Q1',
+    'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q2': 'ELECTRICITY_REACTIVE_TOTAL_Q2',
+    'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q3': 'ELECTRICITY_REACTIVE_TOTAL_Q3',
+    'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q4': 'ELECTRICITY_REACTIVE_TOTAL_Q4',
+    'EON_HU_ELECTRICITY_COMBINED': 'ELECTRICITY_COMBINED',
+    'EON_HU_INSTANTANEOUS_POWER_FACTOR_TOTAL': 'INSTANTANEOUS_POWER_FACTOR_TOTAL',
+    'EON_HU_INSTANTANEOUS_POWER_FACTOR_L1': 'INSTANTANEOUS_POWER_FACTOR_L1',
+    'EON_HU_INSTANTANEOUS_POWER_FACTOR_L2': 'INSTANTANEOUS_POWER_FACTOR_L2',
+    'EON_HU_INSTANTANEOUS_POWER_FACTOR_L3': 'INSTANTANEOUS_POWER_FACTOR_L3',
+    'EON_HU_FREQUENCY': 'FREQUENCY',
+    'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q1': 'INSTANTANEOUS_REACTIVE_POWER_Q1',
+    'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q2': 'INSTANTANEOUS_REACTIVE_POWER_Q2',
+    'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3': 'INSTANTANEOUS_REACTIVE_POWER_Q3',
+    'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4': 'INSTANTANEOUS_REACTIVE_POWER_Q4',
+    'EON_HU_MAX_POWER_ON_L1': 'MAX_POWER_ON_L1',
+    'EON_HU_MAX_POWER_ON_L2': 'MAX_POWER_ON_L2',
+    'EON_HU_MAX_POWER_ON_L3': 'MAX_POWER_ON_L3',
+    'EON_HU_LAST_MONTH_DATA': 'LAST_MONTH_DATA'
 }
 
 REVERSE_EN = dict([(v, k) for k, v in EN.items()])
diff --git a/dsmr_parser/parsers.py b/dsmr_parser/parsers.py
index 3b48cfa..ed7dd30 100644
--- a/dsmr_parser/parsers.py
+++ b/dsmr_parser/parsers.py
@@ -29,8 +29,8 @@ class TelegramParser(object):
         self.telegram_specification = telegram_specification
         # Regexes are compiled once to improve performance
         self.telegram_specification_regexes = {
-            signature: re.compile(signature, re.DOTALL | re.MULTILINE)
-            for signature in self.telegram_specification['objects'].keys()
+            object["obis_reference"]: re.compile(object["obis_reference"], re.DOTALL | re.MULTILINE)
+            for object in self.telegram_specification['objects']
         }
 
     def parse(self, telegram_data, encryption_key="", authentication_key="", throw_ex=False):  # noqa: C901
@@ -84,17 +84,17 @@ class TelegramParser(object):
 
         telegram = Telegram()
 
-        for signature, parser in self.telegram_specification['objects'].items():
-            pattern = self.telegram_specification_regexes[signature]
+        for object in self.telegram_specification['objects']:
+            pattern = self.telegram_specification_regexes[object["obis_reference"]]
             matches = pattern.findall(telegram_data)
 
             # Some signatures are optional and may not be present,
             # so only parse lines that match
             for match in matches:
                 try:
-                    dsmr_object = parser.parse(match)
+                    dsmr_object = object["value_parser"].parse(match)
                 except ParseError:
-                    logger.error("ignore line with signature {}, because parsing failed.".format(signature),
+                    logger.error("ignore line with signature {}, because parsing failed.".format(object["obis_reference"]),
                                  exc_info=True)
                     if throw_ex:
                         raise
@@ -102,7 +102,7 @@ class TelegramParser(object):
                     logger.error("Unexpected {}: {}".format(type(err), err))
                     raise
                 else:
-                    telegram.add(obis_reference=signature, dsmr_object=dsmr_object)
+                    telegram.add(obis_reference=object["value_name"], dsmr_object=dsmr_object)
 
         return telegram
 
diff --git a/dsmr_parser/telegram_specifications.py b/dsmr_parser/telegram_specifications.py
index a5030a4..7cd37bb 100644
--- a/dsmr_parser/telegram_specifications.py
+++ b/dsmr_parser/telegram_specifications.py
@@ -284,29 +284,98 @@ Q3D = {
 SAGEMCOM_T210_D_R = {
     "general_global_cipher": True,
     "checksum_support": True,
-    'objects': {
-        obis.P1_MESSAGE_HEADER: CosemParser(ValueParser(str)),
-        obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
-        obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
-        obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
-
-        obis.ELECTRICITY_REACTIVE_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2: CosemParser(ValueParser(Decimal)),
-        obis.CURRENT_REACTIVE_IMPORTED: CosemParser(ValueParser(Decimal)),
-
-        obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
-        obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
-
-        obis.ELECTRICITY_REACTIVE_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2: CosemParser(ValueParser(Decimal)),
-        obis.CURRENT_REACTIVE_EXPORTED: CosemParser(ValueParser(Decimal)),
-    }
+    'objects': [
+		{
+			'obis_reference': obis.P1_MESSAGE_HEADER,
+			'value_parser': CosemParser(ValueParser(str)),
+			'value_name': 'P1_MESSAGE_HEADER'
+		},
+		{
+			'obis_reference': obis.P1_MESSAGE_TIMESTAMP,
+			'value_parser': CosemParser(ValueParser(timestamp)),
+			'value_name': 'P1_MESSAGE_TIMESTAMP'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_IMPORTED_TOTAL,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_IMPORTED_TOTAL'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_USED_TARIFF_1,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_USED_TARIFF_1'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_USED_TARIFF_2,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_USED_TARIFF_2'
+		},
+		{
+			'obis_reference': obis.CURRENT_ELECTRICITY_USAGE,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'CURRENT_ELECTRICITY_USAGE'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_REACTIVE_EXPORTED_TOTAL,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_REACTIVE_EXPORTED_TOTAL'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_REACTIVE_EXPORTED_TARIFF_1'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_REACTIVE_EXPORTED_TARIFF_2'
+		},
+		{
+			'obis_reference': obis.CURRENT_REACTIVE_IMPORTED,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'CURRENT_REACTIVE_IMPORTED'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_EXPORTED_TOTAL,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_EXPORTED_TOTAL'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_DELIVERED_TARIFF_1,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_DELIVERED_TARIFF_1'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_DELIVERED_TARIFF_2,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_DELIVERED_TARIFF_2'
+		},
+		{
+			'obis_reference': obis.CURRENT_ELECTRICITY_DELIVERY,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'CURRENT_ELECTRICITY_DELIVERY'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_REACTIVE_IMPORTED_TOTAL,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_REACTIVE_IMPORTED_TOTAL'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_REACTIVE_IMPORTED_TARIFF_1'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_REACTIVE_IMPORTED_TARIFF_2'
+		},
+		{
+			'obis_reference': obis.CURRENT_REACTIVE_EXPORTED,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'CURRENT_REACTIVE_EXPORTED'
+		}
+    ]
 }
 AUSTRIA_ENERGIENETZE_STEIERMARK = SAGEMCOM_T210_D_R
 
@@ -345,54 +414,262 @@ EON_HUNGARY = {
 	# Based on V5
 	# Reference: https://www.eon.hu/content/dam/eon/eon-hungary/documents/Lakossagi/aram/muszaki-ugyek/p1_port%20felhaszn_interfesz_taj_%2020230210.pdf
     'checksum_support': True,
-    'objects': {
-        obis.P1_MESSAGE_TIMESTAMP: CosemParser(ValueParser(timestamp)),
-        obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)), # "COSEM logical equipment name"
-        obis.EQUIPMENT_IDENTIFIER_GAS: CosemParser(ValueParser(str)), # This obis is already defined, so it is not possible to "rename" it to "EQUIPMENT_SERIAL_NUMBER"
-        obis.ELECTRICITY_ACTIVE_TARIFF: CosemParser(ValueParser(str)),
-        obis.ACTUAL_SWITCH_POSITION: CosemParser(ValueParser(str)), # This seems to be wrong in documentation, it's not 0-0:96.50.68, but 0-0:96.3.10
-        obis.ACTUAL_TRESHOLD_ELECTRICITY: CosemParser(ValueParser(Decimal)), # This obis is already duplicated, so it will show up as "BELGIUM_MAX_POWER_PER_PHASE"
-        obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_USED_TARIFF_1: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_USED_TARIFF_2: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_ELECTRICITY_USED_TARIFF_3: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_ELECTRICITY_USED_TARIFF_4: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_DELIVERED_TARIFF_1: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_DELIVERED_TARIFF_2: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_3: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_4: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_REACTIVE_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
-        obis.ELECTRICITY_REACTIVE_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q1: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q2: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q3: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q4: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_ELECTRICITY_COMBINED: CosemParser(ValueParser(Decimal)),
-        obis.INSTANTANEOUS_VOLTAGE_L1: CosemParser(ValueParser(Decimal)),
-        obis.INSTANTANEOUS_VOLTAGE_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
-        obis.INSTANTANEOUS_VOLTAGE_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
-        obis.INSTANTANEOUS_CURRENT_L1: CosemParser(ValueParser(Decimal)),
-        obis.INSTANTANEOUS_CURRENT_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
-        obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
-        obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_TOTAL: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L1: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
-        obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
-        obis.EON_HU_FREQUENCY: CosemParser(ValueParser(Decimal)),
-        obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
-        obis.CURRENT_ELECTRICITY_DELIVERY: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q1: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q2: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_MAX_POWER_ON_L1: CosemParser(ValueParser(Decimal)),
-        obis.EON_HU_MAX_POWER_ON_L2: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
-        obis.EON_HU_MAX_POWER_ON_L3: CosemParser(ValueParser(Decimal)), # Only with 3 phase meters
-        # This is a list of last month data (on last day of last month @ 23:59:59),
-        # But it is not clear that what are the elements of the list.
-        # This is not well documented enough, so it is ignored for now.
-        # obis.EON_HU_LAST_MONTH_DATA: 
-        obis.TEXT_MESSAGE: CosemParser(ValueParser(str))
-    }
+    'objects': [
+		{
+			'obis_reference': obis.P1_MESSAGE_TIMESTAMP,
+			'value_parser': CosemParser(ValueParser(timestamp)),
+			'value_name': 'P1_MESSAGE_TIMESTAMP'
+		},
+		{
+			'obis_reference': obis.LUXEMBOURG_EQUIPMENT_IDENTIFIER,
+			'value_parser': CosemParser(ValueParser(str)),
+			'value_name': 'EON_HU_COSEM_LOGICAL_DEVICE_NAME'
+		},
+		{
+			'obis_reference': obis.EQUIPMENT_IDENTIFIER_GAS,
+			'value_parser': CosemParser(ValueParser(str)),
+			'value_name': 'EON_HU_EQUIPMENT_SERIAL_NUMBER'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_ACTIVE_TARIFF,
+			'value_parser': CosemParser(ValueParser(str)),
+			'value_name': 'ELECTRICITY_ACTIVE_TARIFF'
+		},
+		{
+			'obis_reference': obis.ACTUAL_SWITCH_POSITION,
+			'value_parser': CosemParser(ValueParser(str)),
+			'value_name': 'ACTUAL_SWITCH_POSITION'
+			# This seems to be wrong in documentation, it's not 0-0:96.50.68, but 0-0:96.3.10
+		},
+		{
+			'obis_reference': obis.BELGIUM_MAX_POWER_PER_PHASE,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ACTUAL_TRESHOLD_ELECTRICITY'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_IMPORTED_TOTAL,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_IMPORTED_TOTAL'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_USED_TARIFF_1,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_USED_TARIFF_1'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_USED_TARIFF_2,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_USED_TARIFF_2'
+		},
+		{
+			'obis_reference': obis.EON_HU_ELECTRICITY_USED_TARIFF_3,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_ELECTRICITY_USED_TARIFF_3'
+		},
+		{
+			'obis_reference': obis.EON_HU_ELECTRICITY_USED_TARIFF_4,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_ELECTRICITY_USED_TARIFF_4'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_EXPORTED_TOTAL,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_EXPORTED_TOTAL'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_DELIVERED_TARIFF_1,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_DELIVERED_TARIFF_1'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_DELIVERED_TARIFF_2,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_DELIVERED_TARIFF_2'
+		},
+		{
+			'obis_reference': obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_3,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_ELECTRICITY_DELIVERED_TARIFF_3'
+		},
+		{
+			'obis_reference': obis.EON_HU_ELECTRICITY_DELIVERED_TARIFF_4,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_ELECTRICITY_DELIVERED_TARIFF_4'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_REACTIVE_IMPORTED_TOTAL,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_REACTIVE_IMPORTED_TOTAL'
+		},
+		{
+			'obis_reference': obis.ELECTRICITY_REACTIVE_EXPORTED_TOTAL,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'ELECTRICITY_REACTIVE_EXPORTED_TOTAL'
+		},
+		{
+			'obis_reference': obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q1,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q1'
+		},
+		{
+			'obis_reference': obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q2,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q2'
+		},
+		{
+			'obis_reference': obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q3,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q3'
+		},
+		{
+			'obis_reference': obis.EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q4,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_ELECTRICITY_REACTIVE_TOTAL_Q4'
+		},
+		{
+			'obis_reference': obis.EON_HU_ELECTRICITY_COMBINED,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_ELECTRICITY_COMBINED'
+		},
+		{
+			'obis_reference': obis.INSTANTANEOUS_VOLTAGE_L1,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'INSTANTANEOUS_VOLTAGE_L1'
+		},
+		{
+			'obis_reference': obis.INSTANTANEOUS_VOLTAGE_L2,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'INSTANTANEOUS_VOLTAGE_L2'
+			# Only with 3 phase meters
+		},
+		{
+			'obis_reference': obis.INSTANTANEOUS_VOLTAGE_L3,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'INSTANTANEOUS_VOLTAGE_L3'
+			# Only with 3 phase meters
+		},
+		{
+			'obis_reference': obis.INSTANTANEOUS_CURRENT_L1,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'INSTANTANEOUS_CURRENT_L1'
+		},
+		{
+			'obis_reference': obis.INSTANTANEOUS_CURRENT_L2,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'INSTANTANEOUS_CURRENT_L2'
+			# Only with 3 phase meters
+		}, 
+		{
+			'obis_reference': obis.INSTANTANEOUS_CURRENT_L3,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'INSTANTANEOUS_CURRENT_L3'
+			# Only with 3 phase meters
+		},
+		{
+			'obis_reference': obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_TOTAL,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_INSTANTANEOUS_POWER_FACTOR_TOTAL'
+		},
+		{
+			'obis_reference': obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L1,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_INSTANTANEOUS_POWER_FACTOR_L1'
+		},
+		{
+			'obis_reference': obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L2,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_INSTANTANEOUS_POWER_FACTOR_L2'
+			# Only with 3 phase meters
+		},
+		{
+			'obis_reference': obis.EON_HU_INSTANTANEOUS_POWER_FACTOR_L3,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_INSTANTANEOUS_POWER_FACTOR_L3'
+			# Only with 3 phase meters
+		},
+		{
+			'obis_reference': obis.EON_HU_FREQUENCY,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_FREQUENCY'
+		},
+		{
+			'obis_reference': obis.CURRENT_ELECTRICITY_USAGE,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'CURRENT_ELECTRICITY_USAGE'
+		},
+		{
+			'obis_reference': obis.CURRENT_ELECTRICITY_DELIVERY,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'CURRENT_ELECTRICITY_DELIVERY'
+		},
+		{
+			'obis_reference': obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q1,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q1'
+		},
+		{
+			'obis_reference': obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q2,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q2'
+		},
+		{
+			'obis_reference': obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q3'
+		},
+		{
+			'obis_reference': obis.EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_INSTANTANEOUS_REACTIVE_POWER_Q4'
+		},
+		{
+			'obis_reference': obis.EON_HU_MAX_POWER_ON_L1,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_MAX_POWER_ON_L1'
+		},
+		{
+			'obis_reference': obis.EON_HU_MAX_POWER_ON_L2,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_MAX_POWER_ON_L2'
+			# Only with 3 phase meters
+		},
+		{
+			'obis_reference': obis.EON_HU_MAX_POWER_ON_L3,
+			'value_parser': CosemParser(ValueParser(Decimal)),
+			'value_name': 'EON_HU_MAX_POWER_ON_L3'
+			# Only with 3 phase meters
+		},
+		# I'm not sure which datas does this line containes. It should be the data of last minute of last month.
+        # {
+			# 'obis_reference': obis.BELGIUM_MAXIMUM_DEMAND_13_MONTHS,
+			# 'value_parser': NonExistingParser(
+				# ValueParser(timestamp),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal),
+				# ValueParser(Decimal)
+			# ),
+			# 'value_name': 'EON_HU_LAST_MONTH_DATA'
+		# },
+		{
+			'obis_reference': obis.TEXT_MESSAGE,
+			'value_parser': CosemParser(ValueParser(str)),
+			'value_name': 'TEXT_MESSAGE'
+		}
+    ]
 }