Merge pull request #92 from Aeroid/master
Support for (German) EasyMeter Q3D using COM-1 Ethernet Gateway
This commit is contained in:
commit
00248f490e
@ -16,8 +16,8 @@ def console():
|
|||||||
help='alternatively connect using TCP host.')
|
help='alternatively connect using TCP host.')
|
||||||
parser.add_argument('--port', default=None,
|
parser.add_argument('--port', default=None,
|
||||||
help='TCP port to use for connection')
|
help='TCP port to use for connection')
|
||||||
parser.add_argument('--version', default='2.2', choices=['2.2', '4', '5', '5B', '5L', '5S'],
|
parser.add_argument('--version', default='2.2', choices=['2.2', '4', '5', '5B', '5L', '5S', 'Q3D'],
|
||||||
help='DSMR version (2.2, 4, 5, 5B, 5L, 5S)')
|
help='DSMR version (2.2, 4, 5, 5B, 5L, 5S, Q3D)')
|
||||||
parser.add_argument('--verbose', '-v', action='count')
|
parser.add_argument('--verbose', '-v', action='count')
|
||||||
|
|
||||||
args = parser.parse_args()
|
args = parser.parse_args()
|
||||||
|
@ -38,6 +38,9 @@ def create_dsmr_protocol(dsmr_version, telegram_callback, loop=None, **kwargs):
|
|||||||
elif dsmr_version == "5S":
|
elif dsmr_version == "5S":
|
||||||
specification = telegram_specifications.SWEDEN
|
specification = telegram_specifications.SWEDEN
|
||||||
serial_settings = SERIAL_SETTINGS_V5
|
serial_settings = SERIAL_SETTINGS_V5
|
||||||
|
elif dsmr_version == "Q3D":
|
||||||
|
specification = telegram_specifications.Q3D
|
||||||
|
serial_settings = SERIAL_SETTINGS_V5
|
||||||
else:
|
else:
|
||||||
raise NotImplementedError("No telegram parser found for version: %s",
|
raise NotImplementedError("No telegram parser found for version: %s",
|
||||||
dsmr_version)
|
dsmr_version)
|
||||||
@ -102,12 +105,16 @@ class DSMRProtocol(asyncio.Protocol):
|
|||||||
|
|
||||||
def data_received(self, data):
|
def data_received(self, data):
|
||||||
"""Add incoming data to buffer."""
|
"""Add incoming data to buffer."""
|
||||||
data = data.decode('ascii')
|
|
||||||
|
# accept latin-1 (8-bit) on the line, to allow for non-ascii transport or padding
|
||||||
|
data = data.decode("latin1")
|
||||||
self._active = True
|
self._active = True
|
||||||
self.log.debug('received data: %s', data)
|
self.log.debug('received data: %s', data)
|
||||||
self.telegram_buffer.append(data)
|
self.telegram_buffer.append(data)
|
||||||
|
|
||||||
for telegram in self.telegram_buffer.get_all():
|
for telegram in self.telegram_buffer.get_all():
|
||||||
|
# ensure actual telegram is ascii (7-bit) only (IEC 646 required in section 5.4 of IEC 62056-21)
|
||||||
|
telegram = telegram.encode("latin1").decode("ascii")
|
||||||
self.handle_telegram(telegram)
|
self.handle_telegram(telegram)
|
||||||
|
|
||||||
def keep_alive(self):
|
def keep_alive(self):
|
||||||
|
@ -13,6 +13,7 @@ EN = {
|
|||||||
obis.ELECTRICITY_IMPORTED_TOTAL: 'ELECTRICITY_IMPORTED_TOTAL',
|
obis.ELECTRICITY_IMPORTED_TOTAL: 'ELECTRICITY_IMPORTED_TOTAL',
|
||||||
obis.ELECTRICITY_USED_TARIFF_1: 'ELECTRICITY_USED_TARIFF_1',
|
obis.ELECTRICITY_USED_TARIFF_1: 'ELECTRICITY_USED_TARIFF_1',
|
||||||
obis.ELECTRICITY_USED_TARIFF_2: 'ELECTRICITY_USED_TARIFF_2',
|
obis.ELECTRICITY_USED_TARIFF_2: 'ELECTRICITY_USED_TARIFF_2',
|
||||||
|
obis.ELECTRICITY_EXPORTED_TOTAL: 'ELECTRICITY_EXPORTED_TOTAL',
|
||||||
obis.ELECTRICITY_DELIVERED_TARIFF_1: 'ELECTRICITY_DELIVERED_TARIFF_1',
|
obis.ELECTRICITY_DELIVERED_TARIFF_1: 'ELECTRICITY_DELIVERED_TARIFF_1',
|
||||||
obis.ELECTRICITY_DELIVERED_TARIFF_2: 'ELECTRICITY_DELIVERED_TARIFF_2',
|
obis.ELECTRICITY_DELIVERED_TARIFF_2: 'ELECTRICITY_DELIVERED_TARIFF_2',
|
||||||
obis.ELECTRICITY_ACTIVE_TARIFF: 'ELECTRICITY_ACTIVE_TARIFF',
|
obis.ELECTRICITY_ACTIVE_TARIFF: 'ELECTRICITY_ACTIVE_TARIFF',
|
||||||
@ -55,6 +56,9 @@ EN = {
|
|||||||
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
|
obis.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
|
||||||
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL',
|
obis.SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL',
|
||||||
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
|
obis.SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL: 'SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL',
|
||||||
|
obis.Q3D_EQUIPMENT_IDENTIFIER: 'Q3D_EQUIPMENT_IDENTIFIER',
|
||||||
|
obis.Q3D_EQUIPMENT_STATE: 'Q3D_EQUIPMENT_STATE',
|
||||||
|
obis.Q3D_EQUIPMENT_SERIALNUMBER: 'Q3D_EQUIPMENT_SERIALNUMBER',
|
||||||
}
|
}
|
||||||
|
|
||||||
REVERSE_EN = dict([(v, k) for k, v in EN.items()])
|
REVERSE_EN = dict([(v, k) for k, v in EN.items()])
|
||||||
|
@ -11,6 +11,7 @@ P1_MESSAGE_TIMESTAMP = r'\d-\d:1\.0\.0.+?\r\n'
|
|||||||
ELECTRICITY_IMPORTED_TOTAL = r'\d-\d:1\.8\.0.+?\r\n'
|
ELECTRICITY_IMPORTED_TOTAL = r'\d-\d:1\.8\.0.+?\r\n'
|
||||||
ELECTRICITY_USED_TARIFF_1 = r'\d-\d:1\.8\.1.+?\r\n'
|
ELECTRICITY_USED_TARIFF_1 = r'\d-\d:1\.8\.1.+?\r\n'
|
||||||
ELECTRICITY_USED_TARIFF_2 = r'\d-\d:1\.8\.2.+?\r\n'
|
ELECTRICITY_USED_TARIFF_2 = r'\d-\d:1\.8\.2.+?\r\n'
|
||||||
|
ELECTRICITY_EXPORTED_TOTAL = r'\d-\d:2\.8\.0.+?\r\n'
|
||||||
ELECTRICITY_DELIVERED_TARIFF_1 = r'\d-\d:2\.8\.1.+?\r\n'
|
ELECTRICITY_DELIVERED_TARIFF_1 = r'\d-\d:2\.8\.1.+?\r\n'
|
||||||
ELECTRICITY_DELIVERED_TARIFF_2 = r'\d-\d:2\.8\.2.+?\r\n'
|
ELECTRICITY_DELIVERED_TARIFF_2 = r'\d-\d:2\.8\.2.+?\r\n'
|
||||||
ELECTRICITY_ACTIVE_TARIFF = r'\d-\d:96\.14\.0.+?\r\n'
|
ELECTRICITY_ACTIVE_TARIFF = r'\d-\d:96\.14\.0.+?\r\n'
|
||||||
@ -68,3 +69,6 @@ LUXEMBOURG_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imp
|
|||||||
LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
|
LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
|
||||||
SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
|
SWEDEN_ELECTRICITY_USED_TARIFF_GLOBAL = r'\d-\d:1\.8\.0.+?\r\n' # Total imported energy register (P+)
|
||||||
SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
|
SWEDEN_ELECTRICITY_DELIVERED_TARIFF_GLOBAL = r'\d-\d:2\.8\.0.+?\r\n' # Total exported energy register (P-)
|
||||||
|
Q3D_EQUIPMENT_IDENTIFIER = r'\d-\d:0\.0\.0.+?\r\n' # Logical device name
|
||||||
|
Q3D_EQUIPMENT_STATE = r'\d-\d:96\.5\.5.+?\r\n' # Device state (hexadecimal)
|
||||||
|
Q3D_EQUIPMENT_SERIALNUMBER = r'\d-\d:96\.1\.255.+?\r\n' # Device Serialnumber
|
||||||
|
@ -182,3 +182,18 @@ SWEDEN = {
|
|||||||
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
|
obis.INSTANTANEOUS_CURRENT_L3: CosemParser(ValueParser(Decimal)),
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
Q3D = {
|
||||||
|
"checksum_support": False,
|
||||||
|
"objects": {
|
||||||
|
obis.Q3D_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),
|
||||||
|
obis.ELECTRICITY_IMPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
||||||
|
obis.ELECTRICITY_EXPORTED_TOTAL: CosemParser(ValueParser(Decimal)),
|
||||||
|
obis.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE: CosemParser(ValueParser(Decimal)),
|
||||||
|
obis.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE: CosemParser(ValueParser(Decimal)),
|
||||||
|
obis.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE: CosemParser(ValueParser(Decimal)),
|
||||||
|
obis.CURRENT_ELECTRICITY_USAGE: CosemParser(ValueParser(Decimal)),
|
||||||
|
obis.Q3D_EQUIPMENT_STATE: CosemParser(ValueParser(str)),
|
||||||
|
obis.Q3D_EQUIPMENT_SERIALNUMBER: CosemParser(ValueParser(str)),
|
||||||
|
},
|
||||||
|
}
|
||||||
|
@ -128,3 +128,43 @@ TELEGRAM_V5 = (
|
|||||||
'0-2:96.1.0()\r\n'
|
'0-2:96.1.0()\r\n'
|
||||||
'!6EEE\r\n'
|
'!6EEE\r\n'
|
||||||
)
|
)
|
||||||
|
|
||||||
|
# EasyMeter via COM-1 Ethernet Gateway
|
||||||
|
# Q3D Manual (german) https://www.easymeter.com/downloads/products/zaehler/Q3D/Easymeter_Q3D_DE_2016-06-15.pdf
|
||||||
|
# - type code on page 8
|
||||||
|
# - D0-Specs on page 20
|
||||||
|
#
|
||||||
|
# last two lines are added by the COM-1 Ethernet Gateway
|
||||||
|
|
||||||
|
TELEGRAM_ESY5Q3DB1024_V304 = ( # Easymeter an Hauptstromzähler
|
||||||
|
'/ESY5Q3DB1024 V3.04\r\n'
|
||||||
|
'\r\n'
|
||||||
|
'1-0:0.0.0*255(0272031312565)\r\n'
|
||||||
|
'1-0:1.8.0*255(00052185.7825309*kWh)\r\n'
|
||||||
|
'1-0:2.8.0*255(00019949.3221493*kWh)\r\n'
|
||||||
|
'1-0:21.7.0*255(000747.85*W)\r\n'
|
||||||
|
'1-0:41.7.0*255(000737.28*W)\r\n'
|
||||||
|
'1-0:61.7.0*255(000639.73*W)\r\n'
|
||||||
|
'1-0:1.7.0*255(002124.86*W)\r\n'
|
||||||
|
'1-0:96.5.5*255(80)\r\n'
|
||||||
|
'0-0:96.1.255*255(1ESY1313002565)\r\n'
|
||||||
|
'!\r\n'
|
||||||
|
' 25803103\r\n'
|
||||||
|
'\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\xff\r\n'
|
||||||
|
)
|
||||||
|
|
||||||
|
TELEGRAM_ESY5Q3DA1004_V304 = ( # Easymeter an Wärmepumpe
|
||||||
|
'/ESY5Q3DA1004 V3.04\r\n'
|
||||||
|
'\r\n'
|
||||||
|
'1-0:0.0.0*255(1336001560)\r\n'
|
||||||
|
'1-0:1.8.0*255(00032549.5061662*kWh)\r\n'
|
||||||
|
'1-0:21.7.0*255(000557.29*W)\r\n'
|
||||||
|
'1-0:41.7.0*255(000521.62*W)\r\n'
|
||||||
|
'1-0:61.7.0*255(000609.30*W)\r\n'
|
||||||
|
'1-0:1.7.0*255(001688.21*W)\r\n'
|
||||||
|
'1-0:96.5.5*255(80)\r\n'
|
||||||
|
'0-0:96.1.255*255(1ESY1336001560)\r\n'
|
||||||
|
'!\r\n'
|
||||||
|
' 25818685\r\n'
|
||||||
|
'DE0000000000000000000000000000003\r\n'
|
||||||
|
)
|
||||||
|
Loading…
Reference in New Issue
Block a user